Loading...
BOTH-062-2017 Town of Queensbury• Building&Codes Enforcement Office■742 Bay Road■ Queensbury,NY 12804 refDEEP HOLE/PERC TEST � - tQ2_ �� I5a Request for Town Engineer Review Property Owner: C24A? L l: i.i Phone: J C-j5 Property Owner's Address: to Location of Test: 1,0 f } C Crle PO/9 Tax ID#: *Applicant's Engineer: V I(_, i('H /N3 1,�[(),✓,,J ,f�iedo6 Phone: 797 -0&)7 Applicant's Agent: / Phone: Additional Notes: 1. Reason for Request? New Septic System 411 Replacement Septic System Failed Septic System Subdivision Site Plan Review 2.Are Wetlands present? YES NO UNKNOWN *Note: Applicant is required to engage an engineer for design and testing of the system. The Town Engineer's responsibility is to witness system testing only. PLOT PLAN: Plot plan, to scale, to be submitted with application FEE SCHEDULE: a. $200 Flat Fee Date Paid: Check No.: b. OR Fee to be determined during To Be Determined: Site Plan /Subdivision review process SIGNATURE: In carrying out the provisions of Article IV, the Local Board of Health or the enforcement officer may engage the services of a qualified professional consultant for expert review and recommendation arising from the carrying out of the provisions of Art. IV, including but not limited to the review of plans, specifications and reports, attendance at inspections, dye tests, deep hole test pits, septic related deep hole and percolation tests, system installations, and any other aspect of any matter contained in this Art. IV, and any costs incurred in such review shall be paid to the Town by the owner of the property before any approval can be granted under this Art. IV shall become effective within 30 days of presentment of an invoice for same, whichever is sooner. Such costs shall not exceed $1,500 without prior written notice to the party to be charged with same. My signature below indicates I have thoroughly read and understand the instructions, agree to the submission requirements and have completed the application. I also fully understand that additional engineering fees may be necessary per Town of Queensbury Local Law 136-14D. SIGNATURE OF APPLICANT: Date: -, / SIGNATURE OF AGENT: Date: y '1 j Original (B&C File) Canary(Planning) Pink(Applicant) Gold (Town Clerk) WASTEWATER SYSTEM INSTALLATION NOTES Lands N/F Of CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD Francis&Joyce Donohue y , SYSTEMS AND ASTM F481 INSTALLATION OF THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS 14691275 - `�° SYSTEM TO BE INSTALLED IN ACCORDANCE WITH PRODUCT DESIGN AND INSTALLATION MANUAL, STATE AND LOCAL REGULATIONS FOR 10 PRODUCT INFORMATION OR THE' NEAREST DEALER CONTACT PRESBY ENVIRONMENTAL, INC. 143 AIRPORT ROAD, W4I7EFIELD, NH 03598, PHONE , ASPHALT DRI1/E TO BE REMOVED AS NECESSARY 1-800-473-5298 WWW.PRESBYE'CO.COM .. TO ALLOW INSTALLATION OF WASTEWATER SYSTEM. REPLACE ASPHALT UPON INSTALLATION COMPLETION. AFTER EXCAVATION OF TRENCHES TO THE DEPTHS REQUIRED, THE WALLS AND FLOOR OF EACH TRENCH SHALL BE CLEANED AND RAKED IN ORDER , AREAS OF ABSORPTION FIELD NOT UNDER ASPHALT TO LOOSEN SMEARED SECTIONS OF TRENCH. DRIVE TO BE COVERED WITH 4 MIN.OF TOPSOIL. SEED d,ESTABLISH TURF. �^i I PLACEMENT OF PRESBY SYSTEM SAND, PRESBY ADVANCED ENV1R0-SEP71CO PIPE AND STABILIZATION ROAD FABRIC SHALL BE AS SHOWN AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE GRAINED SOILS A A � s AND WASTE MATERIAL IN THE PIPE. " WELL TO 8E DECOMMISSIONED r._. CIRS IN ACCORDANCE WITH N.Y.S. , DEPARTMENT OF HEALTH MINIMUM OF 6- OF SYSTEM SAND, WITH LESS THAN 7% PASSING A if 200 SIEVE REQUIRED AROUND CIRCUMFERENCE OF ADVANCED ENVIRO-SEPTIC PROCEDURES. PIPES. (SEE DESIGN AND INSTALLATION MANUAL FOR COMPLETE SAND AND FILL SPECIFICATIONS) �m s Concrete INSTALLER TO PROVIDE SIEVE ANALYSIS FOR PRESBY SYSTEM SAND TO DESIGN ENGINEER PRIOR TO TRANSPORTING SAND TO THE S TE �. Reta ,n Nail Found mg S.I I/2 IRE r THE PIPE SHOULD BE LAID AT THE GRADES INDICATED MAINTAINING STRAIGHT CONTINUOUS w x. CIRF Ck\ OU GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR k, OTHER UNSUITABLE CONDITIONS .i Ca RY \ P.PRESBYABSORPTIO , r DISP OSAL IOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD. TRENCHES,3 TRENCHES*26 LF o SIO EP f -I EACH,2 AES PIPES P P 0 25 LF PER I HAS BEEN INSTALLED. ly ! DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORP11bN AREA AFTER PIPING � ENCH,150 LF AES PIPE TOTAL I I Concrete .. Reta,mng fl E PROP, DIST.BOX I I 774IS SYSTEM IS DESIGNED FOR WATER CONSERVING FIXTURES AND IS NOT DESIGNED TO ACCOMODATE EXTREME WATER USE OR EXTREME wau PROP.4"BY VENT PIPEDI I ORGANIC -FA SS NT LOADING DEVICES SUCH AS JACJZZI TYPE SPAS OR GARBAGE GRINDERS. " v ,..,...�.... : ;; .. ::;. CKTO PUMP STATION ! —'� e�, .. �, , � • _._.- LOCATION MAP srrE Loca ► .- PROP.FORCEMAIN J ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTFWATER SYSTEM. non APPROX.LOCATION SYSTEM MATERIAL SPECIFICATIONS CIRF EXISTING W/W SYSTEM. Lands N/F Of C EFFLUENT SEWER PIPE f, <; DECOMMISSION 8e 'W REMOVE AS NECESSARY. " r Francs&Joyce Donohue ; ; _ ly,"`� t ;;; PIPING TO BE 4 SCHEDULE 40 PVC. INSTALL WITH� Tl•I 1/8 PER FOOT MINIMUM SLOPE: g „ 604/871 FORCEMAIN " PRESBY SYSTEM SAND GRADATION m � g PIPING TO BE 1-1 2 SDR-9 HUPE. a _ K v � (, PROP.500 GALLON / A � v Concrete m HOUSE SEWER PIPE Retamm m` PUMP STATION " g ' '� o SIEVE PERCENT PASSING u *` ' X / 3, PIPING TO BE 4 SCHEDULE 40 PVC. INSTALL WITH 1/4 PER FOOT MINIMUM SLOPE. Walls PROP.EFFLUENT STABILIZATION FABRIC 3 8" 9.5-mm �t ' s` ® O SEWER STABILIZATION FABRIC TO BE WOVEN GE07EX77LE WITH POLYPROPYLENE YARNS, TENCATE M/RAFI HP370 OR EQUIVALENT. No. 4 (4.75-mm) 95-100% NO WELL ON THIS /orch \ PROP.11000 „4 PRESBY SYSTEM SAND PARCEL.WATER - f No. 8 (2.36-mm) 80-100% O PROP. GALLON PRESBY SYSTEM SA T " x SUPPLY FROM LAKE 4.s ' .._,,,,. ,,: ND 0 8E ASTM C33 WASHED CONCRETE SAND. SEE SYSTEM. '' � . .. SEPTIC " No. 16 (1.18-mm) 50-85% a r HOUSE a, SAND GRADATION FOR SPECIFlC,A110NS � A �� EWER TANK TOPSOIL No. 30 (600-tun) 25-60% d nerx i ,> r ' No� s O i/2"IPF \ PLACE 4 MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED MULCH ANDa us _•ram'. \_ No. 50 (300-tun) 5-30% � , e 2St ias POrcn ESTABLISH TURF. � nk: ep 3 0 0 No. 100 (150-Fun) 0-10% lit r F, 3 Ousee 3 WASTEWATER SYSTEM DESIGN _ D-3% (MUST BE OBTAINED Y SIG No. 200 (75 Fun) Y WASHING) r 3-BEDROOM Bs BED OOM RESIDENCE SYSTEM SAND TO BE ASTM CM WASHED CONCRETE ?� \� WATER SAVING FIXTURES CON ETE SAND 4 aaa,s. Area +Oy� 0.66 Off Line e 10 040± S . ft. w' (1.6 GPF MAX. FLUSH, 3.0 GPM MAX. FAUCETS) INSTALLER TO PROVIDE SIEVE ANALYSIS FOR PRESBY SYSTEM . ' G SAND TO DESIGN ENGINEER PRIOR TO TRANSPORTING SAND 0.23± acres c+\� DESIGN FLOW - 110 GPD/BEDROOM t Adfomer's SYSTEM DESIGN FLOW - 330 GPD TO THE GI House Axle Found ,2.9 :'+ EXISTING SEPTIC TANK - EXISTING 1,000 GALLON PRECAST CONCRETE TO r. NEIGHBORING BE PUMPED, INSPECTED, & REUSED IF f � ` 2 ✓' 23.9 WELL* SUITABLE IN, BAFFLES x; y .. D nd WASTEWATER S EW S ATERSYSTEM � <SETBACK SCHEDULE PUMP ST - :.=F.., A 1lON PROPOSED 500 GALLON PRECAST CONCRETE CIRF oeck W ,z . o O a ,.. N 2ABSORPTION 3 24'W 1.12 ACH FIELD PRESBY® TRENCHES PROPERTY LINE H OUSE GLEN LAKE WELL From Corner o co G + fire Lands N/F Of DESIGN PERCOLATION RATE = 1-5 MIN/IN 1 z„ a s m e SEPTIC TANK 10 10 50 50 NEIGHBORHOOD MAP .P?tp i�1 O pit , 7'0 Michael&Holly Danbury 4' WDE TRENCH LENGTH REQUIRED = 60 LF SITE LOCATION O 1081/47 (PER PRESBY INSTALLATION MANUAL) ABSORPTION FIELD 10, 20' 100, 100, PROVIDE 3 TRENCHES ® 26 LF s Top I/2"IRE �nt,�. ton ds 5tonWasonry walls 3 ± o wak, � au 78 LF TOTAL TO BE PROVIDED no." Dc e wood pek TWO ROWS OF AES PIPE LATERALS REQUIRED PER TRENCH LENGTH OF AES PROVIDED = 6 ROWS ® 25 LF _ 150 LF TOTAL TO BE PROVIDEDTie Line ' e POTABLE WATER SUPPLY IS TO BE ON-SITE WELL Glen Lake Corner SITE PLAN. Stone/Vasonry $/�0 - MAINTAIN 50' MINIMUM SEPARATION BETWEEN SEPTIC 69'± Along Shore wall SCALE. 1"--20' E TANK AND WELL - MAINTAIN 100' MINIMUM SEPARATION BETWEEN ,..m GRAPHIC St/�,,,f�►/�LE 3/4"IPF O ABSORPTION FIELD AND WELL 10 0 5 0 20 ao VARIANCE SUMMARY -- ( IN FEET ) -ABSORPTION FIELD SETBACK TO NORTH PROPERTY LINE FEB 2 2 2017 u 10'REQUIRED 4.6'PROPOSED TC74'�N 617 GUEEI SUURY 5.4'OF RELIEF REQUESTED BUILDING &CODES -ABSORPTION FIELD SETBACK TO EAST PROPERTY LINE 1+ 10'REQUIRED C) 6.7'PROPOSED N 3.3'OF RELIEF REQUESTED T A'T o -FORCEMAIN SET&4CK TO PROPERTY LINE CS PR 1' 0 10'REQUIRED S Y/ oG6.1'PROPOSED ROGREONE ,r 3.8'OF RELIEF REQUESTED p ION RE ajON o FAR STR m o 0 L -DISTRIBU770N BOX SETBACK TO PROPERTY LINE Nca 10'REQUIRED L 5.1'PROPOSED v N M ,FOP, ' 4.8'OF RELIEF REQUESTED NOT VL v0 O oV, E _ a) of 0 _ TAX MAP # 289.10-1-32 N m o ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION of NYS EDUCATION LAW. 0 ISSUED FOR SEPTIC VARIANCE 2116117 No. Revisions Date MAP REFERENCE WASTEWATER SYSTEM PLAN • BASE SURVEY INFORMATION FROM "MAP OF A SURVEY MADE FOR MARIO FASULO," S17VATED IN preparead for THE Dig Safely. STATEOM OF OF NEW YORK.ENSBURY, WARREN DATED SEPTEMBER 22,02016.' Carol L Bodette PREPARED BY. 10 Hemlock Road - Glen Lake New ,York • `d►-n s Call Galore YOU Dig D u s e Town of Queensbury, Warren County, New York ■Wait The Required Time Drawn: JRS Checked: GTH Scole: NOTED Dote: 11/29/16 0 Dig VM ■Confirm Utility Re�pome & Ill Respect The Marks Cam Steves 169 Haviland Road 800.962.7 9G2 Land Surveyors (518) 7450307 Phone 291083-01-S1 n y NY � 1u1MWa��tilfA♦M1yOrIC.00m 169 Haviland Road Queensbury, New York 12804 Hutchins En meerm (518) 792-8474 New York Lic. No. 50135 i+ �7 (518) 745-0308 Fox