Loading...
PTI-004660-2020 08312020INSPECTION WORKSHEET (PTI-004660-2020) Case Number:PT-0472-2020Case Module:Permit Management Inspection Date:08/31/2020Inspection Status:Passed Inspector:Dave HatinInspection Type:Property Transfer Inspections Job Address:5 Antigua Rd Parcel Number:239.17-1-2 Lake George, NY 12845 Contact TypeCompany NameName AgentLittle, O'Connor & Borie, P.C. Primary OwnerMarilyn Breyo Checklist ItemPassedComments WatertightFalse Building Inspector NotesFalse Weather/lack of information/inaccessibilityFalse Service contract (required)False Holding tank (if yes, include capacity)False Capacity in gallonsTrue1000 System/components indicate unacceptableFalse Is there a high water alarm?FalseAlarm not working 8/31/20 recieved Mahoney alarm certification Roof gutters don't discharge over leach fieldFalse Concrete tankTrue Temperature (Fahrenheit)True65 D-box materialFalse Apparent structural damageTrueNo Visible scum layerTrueNo Septic tank (include # of tanks)True1000 gallons Number of tank compartmentsFalseNeed to verify 8/31/20 verified Plumbing fixtures tested & confirmedTrue Evidence of a pipe bypassing tankTrueNo Holding Tank:verify level risescap. w/in 250 galFalse Metal septic or leech tank or cesspoolFalse Whirlpool tub add 250 galFalse System appears undersized/undersized componentsFalse Foundation drain(s)False Verify 50% & 90% floatsFalse Is there evidence of surface water infiltratingTrue O StormwaterFalse Is septic tank sized for bdrms+whirlpool+grinderTrue Garbage grinder add 250 galFalse Tank coverTrue System appears to have functioned adequatelyTrue System passes all function testingTrue Outlet pipe (automatic failure, if yes)False Metal tank (automatic failure)False August 31, 2020Page 1 of 3 INSPECTION WORKSHEET (PTI-004660-2020) Checklist ItemPassedComments Does the pump(s) appear to be operating properly?True Surface discharge? (if yes, to where?)False Roof runoffFalse System needs repairsTrueNo Sump pump not connected to septic systemFalse Sand filterFalse Leaching bedFalse Outflow line invert above leach line invert(s)?False Overflow pipe (automatic failure)False Depth below grade to top of tankTrue6" to 12" Evidence of prolonged high liquid levelTrueNo Access riser? (if yes, depth to cover)TrueInstall access riser on pump station 8/31/20 installed CesspoolFalse Inlet baffleTrue Liquid level AT/ABOVE/BELOW (one) discharge invertTrueNo OtherFalse As-built provided is accurateTrueProvide as built for tank cover locations 8/31/20 recieved as-builts Aerobic systemFalse Recommend upgrade/expand/replace 1+ componentsFalse Number of drop box(es)False TypeFalse OtherFalse Test each fixture flow to septic tankTrue Is tank pumped more than 4x/year?TrueNo Absorption fieldFalse Leaking water fixturesTrueNo Excavate 18" around,no leach field connectedFalse Cracked, corroded or deformed?TrueNo Are there any obvious electrical shortcomings?TrueNo Evidence of liquid above outlet inverts?False Main tank cleanout size and locationTrue12" On-site as-built req'd before insp is completeFalseYes Dosing or pump tank sealedTrue Seepage Pits: NumberFalse Are both switch and alarm operable?TrueSubmit certification from Mahoney Alarms 8/31/20 recieved Raised systemTrueNo failure ModelFalse Solids in D-boxFalse Cracked, corroded or deformed?False Plastic tankFalse OtherFalse ManufacturerFalse August 31, 2020Page 2 of 3 INSPECTION WORKSHEET (PTI-004660-2020) Checklist ItemPassedComments Sump pump(s)False Mound systemFalse Water softener not hooked to septic systemFalse OtherFalse WeatherTrueSunny No treatment tank/other critical component(s)False Outlet baffleTrueNeed to verify 8/31/20 verified Water tight tankTrue Ejector or grinder pump sealedTrue August 31, 2020Page 3 of 3