Loading...
ResCheck z � 04- d3e Permit Number RECEIVED REScheck Compliance Certificate Checked By/Date! 2 9 2004 New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release le TOWN OF QUEENSBURY Data filename:Untitled.rck BUILDING AND CODE PROJECT TITLE:TB201.DGN-"THE NEW FALSETTO" COUNTY: Warren STATE:New York HDD: 7635 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE:01/17/04 DATE OF PLANS: 1/04 PROJECT DESCRIPTION: #134 CHIPPEWA CIRCLE .c .OF N► s/ TOWN OF QUEENSBURY �P pL J. YO T&B ASSOCIATES r•P DESIGNER/CONTRACTOR: n DANFORTH H.CHRISS 1 �• #27 ELECTRIC AVE. t``J' , EAST GREENBUSH,NY 12061 waa �? r; 33 •O•c•SSiGNp`� COMPLIANCE:Passes Maximum UA=558 Your Home UA=424 24.0%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Cathedral Ceiling(no attic) 385 30.0 0.0 13 Ceiling 2:Flat Ceiling or Scissor Truss 24 30.0 0.0 1 Ceiling 3:Flat Ceiling or Scissor Truss 1062 30.0 0.0 37 Wall 1:Wood Frame, 16"o.c. 1660 19.0 0.0 85 Window 1:Vinyl Frame:Double Pane with Low-E 151 0.340 51 Door 1: Solid 18 0.160 3 Door 2: Solid 39 0.320 12 Door 3: Glass 40 0.310 12 Wall 2:Wood Frame, 16"o.c. 1205 19.0 0.0 63 Window 2:Vinyl Frame:Double Pane with Low-E 148 0.340 50 Window 3:Vinyl Frame:Double Pane with Low-E 15 0.300 5 Basement Wall 1: Solid Concrete or Masonry 1355 11.0 0.0 88 Wall height:7.6' Depth below grade:6.6' Insulation depth: 7.6' Floor 1:All-Wood Joist/Truss:Over Outside Air 10 19.0 0.0 0 Floor 2:All-Wood Joist/Truss:Over Outside Air 15 19.0 0.0 • 1 Floor 3:All-Wood Joist/Truss:Over Outside Air 32 19.0 0.0 2 Floor 4:All-Wood Joist/Truss:Over Outside Air 25 19.0 0.0 1 Furnace 1:Forced Hot Air,92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliancewith this Code. 't, Builder/Designer -- FAA,�i f2-Tl t-t • Mir-(SJ Date I/ 177 lef J,,,oF NE w ES J.Cr„0,, r- tor ti,47. . 135 �lir ROFEF SS!G`IP� • REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release le DATE:01/17/04 PROJECT TITLE:TB201.DGN-"THE NEW FALSETTO" Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Cathedral Ceiling(no attic),R-30.0 cavity insulation Comments: 1ST FLR.FAMILY ROOM VAULTED CEILING W/ 10"F.G. [ ] 2. Ceiling 2:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: 1ST FLR.STUDY CEILING 8 1/4"HD F.G. [ ] 3. Ceiling 3:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments:2ND FLR.CEILING W/ 10"F.G. Above-Grade Walls: [ ] 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: 1ST FLR.8 FT.WALLS W/FLR.RIM&W/6"F.G. [ ] 2. Wall 2:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments:2ND FLR.8 FT.WALLS W/FLR.RIM&W/6"F.G. Basement Walls: [ ] 1. Basement Wall 1:Solid Concrete or Masonry,7.6'ht/6.6'bg/7.6'insul, R-11.0 cavity insulation Comments:BASEMENT 8"POURED 8 FT.FOUNDATION WALLS W/3"F.G. Windows: [ ] 1. Window 1:Vinyl Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: 1ST FLR.SIMONTON PROFINISH VINYL SH LOW E/ARGON WINDOWS [ ] 2. Window 2:Vinyl Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: 2ND FLR.SIMONTON PROFINISH VINYL SH LOW E/ARGON WINDOWS [ ] 3. Window 3: Vinyl Frame:Double Pane with Low-E,U-factor:0.300 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: 2ND FLR.SIMONTON PROFINISH VINYL ARCH TOP LOW E/ARGON WINDOW Doors: [ ] 1. Door 1: Solid,U-factor:0.160 Comments: 1ST FLR.THERMA TRU 2868 FIREDOOR [ ] 2. Door 2: Solid,U-factor:0.320 Comments: 1ST FLR.THERMA TRU FRONT DOOR W/SIDELITES [ ] 3. Door 3:Glass,U-factor:0.310 Comments: 1ST FLR.SIMONTON PROFINISH VINYL 6068 LOW E/ARGON PATIO DOOR Floors: [ ] 1. Floor 1:All-Wood Joist/Truss:Over Outside Air,R-19.0 cavity insulation Comments: 1ST FLR.FIREPLACE FLOOR W/MIN.6"F.G. [ ] 2. Floor 2:All-Wood Joist/Truss:Over Outside Air,R-19.0 cavity insulation Comments: 2ND FLR.BED#2/FOYER CANTILEVER FLOOR W/MIN.6"F.G. • [ ] 3. Floor 3:All-Wood Joist/Truss:Over Outside Air,R-19.0 cavity insulation Comments:2ND FLR.MASTER BATH REAR 24"CANTILEVER FLOOR W/MIN. 6" F.G. [ ] 4. Floor 4:All-Wood Joist/Truss:Over Outside Air,R-19.0 cavity insulation Comments: 2ND FLR.BED#3 REAR 24"CANTILEVER FLOOR W/MIN.6"F.G. Heating and Cooling Equipment: [ ] 1. Furnace 1:Forced Hot Air,92 AFUE or higher �1 Make and Model Number (CCD Mrs' GMP/V I (a i+ e.icy Air Leakage: [ J Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [ ] All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit bas at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State ,the Residential Code of New York State or the New York City Building Code ,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an in tegral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. • Heating and Cooling Piping Insulation: [ ] I -HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the I levels in Table 2. Table I. Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)