2005-374 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development - Building & Codes (518) 761-8256
CE RTIFI CATE OF OCCUPANCY
Permit Number: P20050374 Date Issued: Wednesday, November 09, 2005
This is to certify that work requested to be done as shown by Permit Number P20050374
has been completed.
Tax Map Number: 523400-303-005-0001-092-000-0000
Location: 38 MEADOWBROOK Rd
Owner: ELLEN TWISS
Applicant: ELLEN TWISS
This structure may be occupied as a:
Residential Addition By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
-I)j 4 /X--
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20050374 Application Number: A20050374
'Fax Map No: 523400-303-005-0001-092-000-0000
Permission is hereby granted to: ELLEN TWISS
For property located at: 38 MEADOWBROOK Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Tyne of Construction Value
Owner Address: ELLEN TWISS
38 MEADOWBROOK Rd Residential Addition $30,000.00
Total Value $30,000.00
QUEENSBURY, NY 12804-0000
Contractor or Builder's Name /Address Electrical Inspection Agency
SHERLOCK BUILDERS
M JDSON FALLS_ NY
Plans&Specifications
2005-374
384 SQ FT RESIDENTIAL ADDITION (FAMILY ROOM)
$75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, July 07, 2006
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the of Que b T ursday, July 07, 2005
SIGNED BY for the Town of Queensbury.
Director of Building&Co e Enforcement
r
Check Residential Plan Review: One& Two Family Dwellings
N/N/A
(2)Full sets of plans
Over 1,500 sq. ft. Stampe
Design Loads On Plans: 90 and Floor Loads 40 psf
70 Ground Snow Load Sleeping Areas and Attics 30 psf
Calculations:
Window Schedule With Glass Size
Door Schedule/Main Entrance 36"Door
Emergency Escape Or Bedrooms and Habitable Space
Above I Below grade,5.7 sq.ft.
Grade,5.0 sq.ft.
24"(h)x 20"(w)min.
44"Max.Height above floor
Residential Check Paperwork Compliance and Inspectors Checklist: OK
Dampproofmg/Waterproofing Materials On Plans
Foundation Drainage On Plans,if required
6"Drop in 10'Exterior Grader
Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where
Required
Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls
Platforms At Exterior Doors
Stairway Headroom 6' 8'All Stairs 36"Width
Stair Run and Rise
Winder Run and Rise
Spiral Not Allowed From 2d Story
Smoke Detectors Battery Backup and Proper Location
Bathroom Fixtures Proper Clearance
Hall Width,36"min.
Handrails More Than One Riser On Open Sides
Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht.
i
Safety Glazing Notes For Required Areas
A_ Garage Fire Separation
Garage Floor Sloped
Attic Access
Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access
Carbon Monoxide Detector Lowest Sleeping Level
Soil Test Results, if required
Septic To Well Or Water Line Separation
All Paperwork Signed
Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY
(518)761-8205
Application for Fuel Burning Appliances & Chimneys
applicable to solid fuel & vented gas appliances
Date , 20 Permit No.
Application is hereby made to the Building& Codes Office for the issuance of a Building and Use
Permit pursuant to the New York State Fire Prevention and Building Code. The applicant or owner
agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of
these requirements and also will allow all inspectors to enter premises to perform required inspections_
NOTE to applicant: Rough-in and Final Inspections are required.
Applicant Information Fuel Burning Appliance Information
f , (circle appropriate words)
Name: Stove: wood coal pellet gas
Fireplace insert
Address: { 41 4_7� C Fireplace, factory-built: wood gas
Fireplace, masonry: wood gas
Furnace: wood gas oil
Phone: 7 7r '
If non-masonary applicance, please provide
Owner: t/ t t 1 ,S Manufacturer Name:
Address � fi' tl �. � Model Number.y Ago,
Chimney Information
Phone: - (circle appropriate words)
Masonry block brick stone
�3 , Flue 'tile steel size: inches
Exact Address- irr-•C YJ ` a: Y5,.: •
of construction or ins llati n Factory-Built ,
Manufacturer name:
Model Number: L Fr*-
Note: Listed By: Number:
Construction/Installation must
conform to NYS Fire Prevention &,Build4ig Indicate(circle) chimney material:
Code. Consult available Town of Queensbury
Handouts regarding required inspections. Double wall / Triple wall / Insulated / Direct venting
Chimney Liner
Caer�f�z-'�Department Tc� •�?�Qu��,�bury, New-Yoram:
Fire Marshal Code# $Collected Refunded Received fi-oni (refunded to):�c4l �..
4 address:
A 173 3389 (190) Public Safety
A 233 2655 (230)Minor Stiles
DATE:
White(Applicant) / Green(Fire Marshal) ! Yellow(Bldg.Dept.) ! Pink R Goldenrod(Cashier's Dept.)
Permit No. 1),5— 3`I
Building&Codes Office-Department of Community Development-Town of Queensbury Fee Paid
742 Bay Road,Queensbury,NY 12804 Recreation Fee
Dave Hatin,Director codes@aueensburv.net
Phone: (518)761-8256 FAX: (518) 745-4437
Principal Structure Building Permit Application
Application & Plans subject to review before issuance of a valid permit for construction._
Instructions: A permit must be obtained before beginning construction. No inspections will be made until the
applicant has received a valid building permit. All applicants' spaces on this application must be completed and
must appear on the application form. .—/—
Applica
Owner:
Address Address: roc
SHERLOCK BUILDERSHome P 29 LAFAYETTE STREET Home Phone: - $
Email A. HUDSON FALLS, NY 12839 Email Address:
Cell Phc PHONE�518) 747-7327 FAX (518) 747-4611 Cell Phone:
FAX PhGr"K�/1 �r�=40!e>5k�44rb , CE H FAX Phone:
Person responsible for supervision of work with respect to building and codes compliance:
Name: v e
Address: ,e St, Ph/one
Location of proposed construction: Lot No. Legal Address: Oe a�vu� �Y�o�C j d u e DNS �gcry
Tax Map Number: 0 5� — Subdivision Name:
Estimated Cost of Construction: o� RECEIVED
Proposed construction is for: Residential Use —Commercial Use
Name of Business:
TOWN
LDIN DD Y
NO ODE
If proposed construction is an addition,what will use of new addition be?
New Addition Alteration Proposed Construction 10 Floor 2^d floor Other Total Proposed
structure (Occupancy Type) Sq.Ft. sq.ff. Sq.Ft. Square feet Height
Ft.&.In.
Single-Family Dwellin $
Two-Faml Dwelling
Townhouse
Multifamily Dwelling
Number of Units:
Office
Mercantile
Manufacturing
Other:
Attached Garage 1, 2, 3
Type of Heating System: Electric, Oil Gas, Wood, Forced Hot Air, Baseboard, Other:
Is a fireplace and/or woodstove being installed, please refer to a separate application. ZYes —No
Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review.
The Building and Codes Office will allow commencement of your proposed project only after
Issuance of your permit.
Declaration: Please sign below after you have carefully read the statement:
To the best of my knowledge, the statements contained in the application, together with the plans and
specifications submitted, are a true and complete statement of all proposed work to be done on the described
premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the
proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner.
Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance
being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a
licensed surveyor, drawn to scale, showing actual location of all new construction.
Date: Applicant/Builder Signature:
The application of dated is hereby approved and
permission granted for the construction, reconstruction or alteration a building/and or accessory structure as set
forth above. � -
Date: LAuthorized Signature:�"
L:\Sue-Hemingway\Building.Pe it.F RMS\Principal Structure Permit Application.doc v;12/14/04
Queensbury Building & Code Enforcement - Residential Final Inspection
J�
Date Ins
Office No.(518)761-8256 Arrive: am/pm Depart: A C am/pm
Inspection request received:
p q _ Inspector's Initials:
NAME: L j e,� -� PERMIT#:
LOCATION: DATE: CT
TYPE OF STRUCTURE 7`-�"
Comments
Yes No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location >>
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete `
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 i ate or
as Valve shut-off expo ed/r lator 18 inches above grade
Interior m doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every be room area:
Inter Connected: Battery backup:
Carbon Monoxide Detector � r -t� (L,C>
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area !
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Tern 110
Enclosed Stairs Sheetrock Underside minimum%s"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Gl ss Enjclosure V
Final Electrical a
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required.,
Flood Plain Certific tion re ired
Okay to issue C/Vor C/O [lemporary/Permanent
L:\Building&Codes orms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.
Main Office 176 Doe Run Road-Manheim,PA 17545
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
Permit No......................................Cert. N 2 93741 Cut-in Card No................................
Owner..............t.....Tl!urk5.;_?....................................................................................................../.'...........
Location...��. ..../1l�?r/�ll �2e � / .............
.............. ........................................................................................................
/./ l Y7U �C/GG/�/ ,qr ............
Installation Consisting of... .....p........:...............�i.............................../�..../p� .......
..................................................................................................................................................................................
..................................................................................................................................................................................
Installed By......�.�......�.c�{f;-/L[,OzX:�....................................Lic.No..................................................
The conditions following governed the issuance of this certificate,and any certificate previously issued is
-ancelled:-
This certificate only covers the electrical equipment and installation conditions as of date. Upon thf
introduction of additional equipment or alterations,application shall be promptly made for inspection.
Inspectors of this Company shall have the privilege of maki inspections at any time, and if it;
rules are violated,the Company shall have the right to re ke thi c ifica
Il o t
Date.........'".. .. . ........................... INSPECTOR.... ... ..................................................................................
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No.(518)761-8256 / Arrive: am/pm Depart 1 ,00 am/pm
Date Inspection request received: /`' Inspector's Initials:
NAM r� S S - �—
E. �I y �� 3 5 ._
LOCATION: i PERMIT#: �� 3 �/
DATE:
TYPE OF STRUCTURE: _
Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location.
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6"
Roof Complete/Exterior Finish Complete
Guard 30 in.or more a)stairs,decks,patios. (� —
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in.or more
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors V
Interior Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock Underside minimum
Gypsum
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post or Wall
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft.or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertigbt
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: / Every Bedroom:
Outside every bedroom area:
Inter Connected: / Battery backu :
Carbon Monoxide Detector
Bathroom Fans,if no window _
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
Garage Floor Pitched _
Garage fire rooftn /%hour fire door/door closer
Duct work Seated properly
Gas Logs in Sealed or Glass Enclosure
Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, 1 s . ft,150 s . ft. vents
Building No./Address visible from road
Final Electrical
Site Plan /Variance required
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Flood Plain Certification, if required
Okay to issue C/C or C/O Te rar /Permanent
L:\PamW\Buildina&Codes\Inspection Forms\Res. Final Insp.form 2.docLast printed 2/12/04
Town of Queensbury Fire Marshal
742 Bay Road
Queensbury,NY 129M
761-8205/761-8206
fax 745-4437
Factor
v Bull as Fire la / t e Ins ecti n Report
Notice:New York State requires that all UL Listed,factory u t appliances be installed according to the instructions and
specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's
instructions or specifications is allowed.
Permit#, - Schedule Inspection Timej. / pm anytime Inspecto
Name S S Address -3 17 4Z�_- Rough In,_,_,Fin
Appliance Man darer Model#
Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall insulated
Yes No N/A Comments
Floor Protection
Clearances to Combustibles (all sides)
Firestop(s) Vertical Chase _
Wall Penetration
_Z
Vent Clearances to Combustibles
Vent/Chimney Termination
Chimney height must be 3 feet above roof
penetration;2 feet above any combustible
construction within 10 feet —'
Gas Shut-Off Valve
Combustion Air v�����✓'�
Hearth Extension (if any)
Mantel
Height above Up opening
Witness Operation
Tank Placement(if LP)
Pink—Fire Mars"
White—Btd{din;Dept 1'r�low 45aet r
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection requ re ei e /6-
Queensbury Building & Code Enforcement Arrive: m/p epart: ate
742 Bay Road, Queensbury, NY 12804 Inspector's Initi G
r'
NAME: PER # 3-7
LOCATION. 38" INS CT ON. a
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing / Nail Plates
Plumbing Vent/ Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air/ Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
50 P.S.I for 15 minutes
sulati n Residential Check/ Commercial Check
Pro ent Attic Vent \0
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
LAPam Whiting\Building&CodeAnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building& Code Enforcement Arrive: _am/ part: _am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT#:
LOCATION: INSPECT ON: 7
73�—
TYPE OF STRUCTURE:
Y Framing N N/A COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
chor Bolts 6 ft.or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side '/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LASueHeming%vay\Building.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003
Framing / Firestopping Inspection Report CC�
Office No.(518) 761-8256 Date Inspection re st r idpd:
Queensbury Building&Code Enforcement Arrive: Depart a�
742 Bay Road, Queensbury,NY 12804 Inspector's Initials•
L-1 7LI
NAME: n C .N PERMIT#:
LOCATION: ? INSPECT ON:
TYPE OF STRUCT
Y N /A
ng CqM NTS
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly "—
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %z w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2, 3 hour
Fire wall 2, 3,4 hour ►"
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
1
Framing / Firestopping Inspection Re
Office No. (518) 761-8256 Date Inspection r qu st ec ved: /
Queensbury Building& Code Enforcement Arrive: m/ m epart: - a pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initia
NAME: PERMIT#:
LOCATION: — INSPECT ON:
TYPE OF STRUCTURE:
Y N Framing N/A COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf Eade
L:\SueHemingway\Building.Codes.Inspection.FORvtS\Framing Firestopping Inspection Report.doc January 28,2003
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/p � Depart: `pm
YL
742 Bay Rd., Queensbury, NY 12804 Inspector's Initials:",___
NAME: <k_ PERMIT#: n :S-37_
LOCATION: INSPECT ON: _ —
TYPE OF STRLTCTUR :
Comme is
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement I
of the concrete.
Materials for this purpose on site.
Foundation Wallpour
Rein cement in Place
undation Dampproofing
Founda ' /Waterproofing
e of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab _
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R- _
Rough Grade 6 inch drop within 10 ft.
LASueHemingway\Building.Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003
J�
/ t
Foundation Inspection Report
Office No. (518)761-8256 Date Ins ection requ c ed: f
Queensbury Building &Code Enforcement Arrive: a epart: a v'
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:
t
RMIT#:
NAME: _ —
LOCATION: ,..._ �.3_ rr,e,Ar-,owA�-,- & INSPECT ON: �_ v
TYPE OF STRUCTURE:
Comments
----- y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R- _
Rough Grade 6 inch drop within 10 ft.
1.:1SueHemingway\13uilding.codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003
Foundation Inspection Report
�f
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/p C--- Depart: m
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials. -
f
NAME: ]�uS PERMIT#: y -
LOCATION: INSPECT(JN: 1
TYPE OF STRUCTURE: �
Comments
N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
oundation/Wal].pour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab _
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R- _
Rough Grade 6 inch drop within 10 ft.
L:\SueHemingway\Building.Codes.Inspcetion.FORMS\Foundation Inspection Report.doc January 28,2003
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/p Depart:
742 Bay Rd., Queensbury, NY 12804 Inspector's Initials:
NAME: ` APERMIT#: 0
LOCATION: INSPECT ON: _
TYPE OF STRUCTURE:
Comments
+� Y N N!A
Doting- i
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:SueHerningway\Building.Codes.InspectionTORMSWoundation Inspection Report.doc January 28,2003
Permit Number II
REScheck Compliance Certificate Checked By/Date
2000 IECC
REScheck Software Version 3.6 Release la
Data filename: C:\AutoCad Drawings\Sherlock Builders\Twiss\ResCheck.rck
PROJECT TITLE: New Home Project
CITY: Saratoga Springs
STATE: New York
HDD: 6998
CONSTRUCTION TYPE: Single Family
WINDOW/WALL RATIO: 0.27 RECEIVED
DATE: 05/26/05
DATE OF PLANS: May 30, 2005 MAy {l�
PROJECT DESCRIPTION: TOWN OF QUEENSBURY
Ellen Twiss BUILDING AND CODE
38 Meadow Brook Road
Queensbury, New York 12804
518-798-8832
DESIGNER/CONT RACT OR:
Saratoga Engineering& Design
Douglas W. Adams PE
74 Rolling Hills Drive
Gansevoort,New York 12831
(518)587-2518
PROJECT NOTES:
Builder. Sherlock Builders
Hudson Falls,New York 12939
747-7327
COMPLIANCE: Passes
Maximum UA= 95
Your Home UA= 94
1.1%Better Than Code(UA)
Gross Glazing
Area or Cavity Cont. or Door
Pcrimet $-Value R-Value U-Factor MA
Ceiling 1: Flat Ceiling or Scissor Truss 384 38.0 0.0 12
Wall 1: Wood Frame, 16" o.c. 128 21.0 0.0 6
Window 1: Vinyl Frame:Double Pane with Low-E 22 0.350 8
REScheck Inspection Checklist
2000 IECC
REScheck So$ware Version 3.6 Release la
DATE: 05/26/05
PROJECT TITLE:New Home Project
Bldg. I
Dept-
Use I
I
I Ceilings:
[ ] I 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-38.0 cavity insulation
Comments:
I
Above-Grade Walls:
[ ) I 1. Wall 1: Wood Frame, 16" o.c., R-21.0 cavity insulation
Comments:
[ ] I 2. Wall 2: Wood Frame, 16" o.c., R-21.0 cavity insulation
Comments:
[ ] I 3. Wall 3: Wood Frame, 16" o.c., R-21.0 cavity insulation
Comments:
I
Windows:
[ ] I 1. Window 1: Vinyl Frame:Double Pane with Low-E, U-factor 0.350
I For windows without labeled U-factors, describe features:
I #Panes Frame Type Thermal Break? [ ]Yes [ ]No
Comments: (2)TW26310
[ ] I 2. Window 2: Vinyl Frame:Double Pane with Low-E, U-factor. 0.350
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? [ ]Yes( ]No
Comments: (1)34310
I
Doors:
[ ] I 1. Door 2: Solid, U-factor. 0.500
Comments: passage door
[ ] ( 2. Door 1: Glass, U-factor. 0.350
Comments: (2)FWG6068
i
Crawl Space Walls:
[ ] i 1. Crawl 1: Solid Concrete or Masonry, 5.5' ht/4.0'bg/5.5' insul,
R 21.0 cavity+ R-5.0 continuous insulation
Comments:
Applies to walls ofunventilated crawl spaces.
Exterior insulation must have a rigid, opaque, weather-resistant protective covering that
I covers the exposed(above-grade)insulation and extends at least 6 in. below grade.
I
Air Leakage:
[ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air
I leakage must be sealed.
[ ] I Recessed lights must be 1)Type IC rated, or 2)installed inside an appropriate air-tight assembly
with a 0.5" clearance from combustible materials. Ifnon-IC rated, the}fixture must be installed with a
3" clearance from insulation.
I
( Vapor Retarder:
[ ] ( Required on the warm-in-winter side ofall non-vented I med ceilings, walls, and floors.
I
Materials Identification:
[ ] ( Materials and equipment must be installed in accordance with the manufadure's installation instructions.
[ ] ( Materials and equipment must be identified so that compliance can be determined.
[ ] ( Mangy manuals for all installed heating and cooling equipment and service water heating
( equipment must be provided.
[ ] ( Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications.
I
( Duct Insulation:
[ ] ( Duds in unconditioned spaces must be insulated to R-5.
( Ducts outside the building must be insulated to R-6.5.
I
( Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics(adhesives),
masticplus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B.
Exception:Continuously welded and locking-type longitudinal joints and seams on ducts
J operating at less than 2 in. w.g. (500 Pa).
[ ] ( The HVAC system must provide a means fir balancing air and water systems.
I
J Temperature Controls:
[ ] J Thermostats are required for each separate HVAC system. A manual or automatic means to
( partially restrict or shut offthe heating and/or cooling input to each zone or Boor shall be provided.
I
( Service Water Heating:
[ ] ( Water heaters with vertical pipe rises must have a heat trap on both the inlet and outlet unless the
I water heater has an integral heat trap or is part ofa circulating system.
[ ] ( Insulate circulating hot water pipes to the levels in Table 1.
I
( Circmlating Hot Water Systems:
[ ] ( Insulate circulating hot water pipes to the levels in Table 1.
I
J Swimming Pools:
[ ] ( All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
( ofthe heating energy is from non-depletable sources. Pool pumps require a time clock.
I
( Heating and Cooling Piping Insulation:
[ ] J HVAC piping conveying fluids above 105 °F or chilled fluids below 55 T must be insulated to the
( levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickmess in Inches by Pipe Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(Fl Un to 1„ Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping Svstem Types Range F 2"Runouts 1" and Less 1.25"to 2" 2.5"to 4"
Heating Systems
Low Pressure/Temperone 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(fir feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD(Building Department Use Only)
Wall 2: Wood Frame, 16" o.c. 128 21.0 0.0 5
Window 2: Vinyl Frame:Double Pane with Low-E 14 0.350 5
Door 2: Solid 21 0.500 11
Wall 3: Wood Frame, 16"o.c. 192 21.0 0.0 6
Door 1: Glass 84 0.350 29
Crawl 1: Solid Concrete or Masonry 308 21.0 5.0 12
Wall height: 5.5'
Depth below grade: 4.0'
Insulation depth: 5.5'
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other culations submitted with the permit application. The proposed building has been designed to
meet the 2000 IECC irements in REScheck Version 3.6 Release la(firmerly MECcheck) and to comply with the
mandatory requirements listed in 7theEScheck Ins on Checklist.
Builder/Designer Date 165