Loading...
2005-420 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUP-A--N- CY Permit Number: P20050420 Date Issued: Monday, May 02, 2011 This is to certify that work requested to be done as shown by Permit Number P20050420 has been completed. Location: 68 LAMBERT Dr Tax Map Number: 523400-301-018-0002-014-000-0000 Owner: THOMAS & HEATHER DARNLEY Applicant: THOMAS & HEATHER DARNLEY This structure may be occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the owner of the responsibility for compliance with Site Plan property P tY P � Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050420 Application Number. A20050420 Tax Map No: 523400-301-018-0002-014-000-0000 Permission is hereby granted to: THOMAS &HEATHER DARNLEY f For property located at: 68 LAMBERT Dr t in the Town of Queensbury,to construct or place % at the above location in accordance with application together with plot plans and other rmation hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Quee Zoning Ordinance. T e of Co tru 'orb Value Owner Address: TH AS & EATHER DARNLEY Residen 1 ition $40,000.00 LAMBER Dr �e QUEENSBU�Y, NY 12804-0000 Tot $40,000.00 d/,, Contractor or B\1- 's Name/ dresslectrical Inspe n Agency DANIEL WOOD792-1632 NY 12804-0000 1 Plans &Specifications 2005-420 1 1430 SQ FT RESIDENTIAL ADDITION $171.60 PERMIT FEE PAID- THIS PERMIT EXPIRES: Tuesday,July 01, 2008 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date. Dated at the To of nsb , ot, uly 01, 2005 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050420 Application Number: A20050420 Tax Map No: 523400-301-018-0002-014-000-0000 Permission is hereby granted to: THOMAS &HEATHER DARNLEY For property located at: 68 LAMBERT Dr in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tie of Construction Value Owner Address: THOMAS &HEATHER DARNLEY 68 LAMBERT Dr Residential Addition $40,000.00 Total Value $40,000.00 QUEENSBURY, NY 12804-0000 Contractor or Builder's Name /Address Electrical Inspection Agency DANIEL WOOD 792-1632 NY 12904-0000 Plans&Specifications 2005-420 1430 SQ FT RESIDENTIAL ADDITION $171.60 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,July 01, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Friday, u O1,2005 SIGNED BY 14for the Town of Queensbury. Director of Building& Code Vnforcl§lient Job Site Address: & l.I -�( 2' �>✓ Date:. Owner: Application No. File No. 1005 61 Building Permit Calculation. Sheet RECEIVED Natural Light, Ventilation & Emergency Egress Requirements JUNI I 1 '2 .NOW Habitable Area of Req. Light Actual Req. Vent .Actual Sq.Ft. Remarks TOWN OF(� EEN$BURY Room Room 8%of Room Light 4%of Room Vent Opening for BUILDING ND CODE in Axea Square Area Square Egress Square Footage Footage Feet U\SueHamingwal Building.Permit.FORMS\Nat.Light.Ventil.Calcu lation.Sheet.doc )n WINDOW SCHEDULE Job Site/Address: i_Aor� - z iZa�/L Date: (� i ���� �CEIVED Owner: tp1xLLJC.j} Application No. L(1Ga jam 62,f446 aJ D2A-,A L 6 A,2 Window Window Window Unit or Rough Rough SQ.FT. SQ.FT SQ.FT. Clear CI"LOMPto—nCls re Number or Manufaturor Model/Type Stock Openin Opening Glass/Vis Egress/Cle Opening Ope Letter on Name Numbe g Height lble Vent ar Width in He Plan Call Width Light Opening Inches In Inches Size Example Entry A Andersen Narroline 3062 3' 2 6'5 % 15.30 8.36 6.01 34 2415/3599 Tempered Double 1/3" 11116 Glazing Hun CADocuments and Settings\SueU.oca1 SettingATeM Window Schedule.doc Check Residential Plan Review: One&Two Family Dwellings /N/N/A (2)Full sets of plans Over 1,500 sq. ft. Stampe Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq.ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofing/Waterproofing Materials On Plans Foundation Drainage On Plans,if required 6"Drop in 10'Exterior Grade V,, _— �" Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where Required Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width A- Stair Run and Rise t 1 Winder Run and Rise Spiral Not Allowed From 2 Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width,36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation Garage Floor Sloped Attic Access Roof over 30"-22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level —4N->F-> O p� Soil Test Results,if required Septic To Well Or Water Line Separation All Paperwork Signed Town of Queensbury 742 Bay Road, Queensbury, NY 12804 -Biding & Code Enforcement Building pmnit# Plxme:(518)761-8256 Daft- Fax: (518)745-4437 Em g: codes eeenstxuy net Deaf = 4 Yoix bnldmg pen d application has b=nvkwtd aad hid to be deficient is the following IU=detadsmM io be ad&d to ornoted ou bo&se c ofpbm Pk=fcdfM#a c omba this ofkv with anYTWSOW 3egaardmg this matta- -, Si�cereh�, EtTflDM&CODW OMCE L\svc}tes gngsvaylE�e iagPunoil�oxhs dcfi c building pawA he 2003=d- i Application for Permit-Septic Disposal System Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256 1. OWNER INFORMATION: [gf: Lib'l ,k ......................:........................Office Use Location of installation: _.............._..... ................... T 01244L, File Permit No. ' Tax Map No.30 ,1&__2- /_14 .,. Owner's Name: -OAZJ Fee Paid ...............................c..._.....`..../ .. ................... �/ Address: (1iI�(? t'�IZI�i� C[:L+�'i?ji��lZi ( C� ED 2. INSTALLER'S NAME : 2005 PHONEUR .. .. 3. RESIDENCE INFORMATION: (circle year of dwelling,indicate#,bedroom(s) a i F E ODEY bedrooms with applicable gallons per bedroom to equal Year of House: No of Bedrooms x Computation Total iDaily Flow i 1980 or older x 150 gandrm i 1980-1991 x 130 gal/bdrm = n ,, 1991 -present I x 110 gal/bdrm = i i';�? � i Garbage Grinder Installed yes— / no Spa or Hot Tub Installed yes_ / no X 4.' PARCEL INFORMATION: (circle applicable information&indicate measurements) Ton-ography Soil Nature Ground Water Bedrock or Im ervi us Material Domestii Wate S ' 1 Flat sand at what depth at what depth munici al Rol ring oam 0//�, feet feet -well— Steep slope clay if well, water sup y _%slope other from any septic-system depth: absorption is ft. other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: j -so minute per inch j i 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a lic used professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank: 11�0 ' gallon(min.size 1,000gal.) (Cwro � 126$ 0\lG exe 1600 C46L" � J i Tile Field: each trench OAN ft. Total System Length: ft. i Seepage Pit(s): number of—_I size of each: ft. by ft. I = EKK�7r i Size a Stone to be used: # / depth or thickness feet! Bed System Size: i-Ill�- x Alternative System: length and/or, size 6. HOLDING TANK SYSTEM: (if required) W%A Number of tanks: / Size of each: gallons /TOTAL C2pacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. i 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136 29 ofthe Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void.; I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Qrdin�nce. i I Signature of responjiba person ate ow" OXIC(Illsbui-Y �c. �vc1-4 stsul : �wsil c: I)ixslt/Kstt t:Iiaist(t•r A-11S )MI'VION, I"II,'IA.) SE'P 'IL11TION RVANi. IRIMINXI'S Cz Wi llxtZol j lit it I 0^9 •�Sttrltt' ,CJt$ltic� .. fit it'�� 1 'r • i l .� Scr�lic, f•tDLt.b Rahn .,--- i 1 I j t i ,i 7. SICTNATURE Permit No. - � Building&Codes Office-Department of Community Development-Town of Queensbury Fee Paid 742 Bay Road,Queensbury,NY 12804 Recreation Fee Dave Hatin,Director codes@aueensburynet Phone: (518) 761-8256 FAX: (518) 745-4437 Principal Structure Building Permit Application Application & Plans subiect to review before issuance of a valid permit for construction. Instructions: A permit must be obtained before beginning construction. No inspections will be made until the applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the application form. J^ Applicant/ - 1 ' 6' Owner: ta_sa_.g lu'mu Address: 141 1,3�1Z (ZAJ Address: (IF LhMP�t r1, 24i4c i LAID. &f-,k) 0e,_U�' l2 =, c�o � Oiz1 �1 . 0 I 126C7 Cf Home Phone: 1 Home Phone: ct(�1� Email Address: Email Address: Cell Phone: L1/i Cell Phone: FAX Phone: -. FAX Phone: Person responsible for supervision of work with respect to building and codes compliance: Name: nib 400 i;5olgx:A�2 Address: Phone Location of proposed construction: Lot No. Legal Address: Tax Map Number: 30I, 1 ) - 2 - 14, Subdivision Name: Estimated Cost of Construction: $ 40,0W. RECEIVED Proposed construction is for: 4Residential Use _Commercial Use JUN 13 2005 Name of Business: 01A MOWN OF QUEENSBURY If proposed construction is an addition,what will use of new addition be2BUILDIN RAND CODE New Addition Alteration Proposed Construction ld Floor 2^d floor Other Total Proposed structure (Occupancy Type) Sq.Ft. sq.ft. Sq.Ft. Square feet Height Ft.L irl. Single4cmily Dwelling ' Two-Family Dwelling Townhouse Multifamily Dwelling Number of Units: Office Mercantile Manufacturing Other: Attached Garage 1, 2, 3 Type of Heating System: Electric, Oil, Gas, Wood, Forced Hot Air, Baseboard,,Other: Is a fireplace and/or woodstove being installed, please refer to a separate application. _Yes 2� No Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review. The Building and Codes Office will allow commencement of your proposed project only after issuance of your permit. Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of al new co cti Date: Applicant/ Signature: The application of dated is hereby approved and permission granted for the construction, reconstruction or alteration of a building/and or accessory structure as set forth above. Date: Authorized Signature: LASue Hemingway\Building.Permit.FORMS\Principal Structure Permit Application.doc V:12/14/04 t Residential Final Inspection Office No. (518) 761-8256 Date Irispec io�quest received: Queensbury Building&Code Enforcement Arrive: ZJ amt Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NTAME: / �(y PERMIT#: LOCATION: r DATE: 27 Ll TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches 3/4 hour fire door/door closer Garage fireproofing Duct work Sealed properly Attic access 30 in.x 24 in.x 30 in.(lit.)In accessible area Crawl Spaces 18"x 24"access, 1 s , ft.-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C Cert, Of Compliance) Okay to issue Temporary C/O(Cert. Of Occupancy) Okay to issue Permanent C/O(Cert. Of Occupancy) L:\SueHemingwaySuilding.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003 Queensbury Buildin ' & Code Enforcement - Residebtial Final Inspection \im No. (518)761-8256 Arrive: arn/pin Depart 2,�. am/pm Date Inspection request received: Inspector's Initials. z C. NAME: `MCA l° - PERMIT LOCATION: DATE TYPE OF STRUCTURE: .� Comments: Yes r Build Buildhy Number Address visible from mad ,sk ; ChImM Height/*Bw Vent/Dired Vent Location I Fresh Air Intake 3 inch Plumbina Vent through roof minimum 6 inches Roof C /Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guam at stairs decks ios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck es 36 Indies or more Handrall Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped RompCom lian t Grade away from foundation 6 Indies with 10 feet 6 inch clearance to sill plate Gas VaNe shin-off / ulator 18 inches above grade interior privaq/trim/doors/main entrance 36 inches Bathroom/Kitchen wateftht /Window in stairwells Mtj!y gluing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: inter Contacted: BeIterybadku Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spa c es 18 inch x 24 inch access 1 tt:150 sq.ft.vents Bathmorn Fans if no window ~� Plumbs %cures = � Foundation insulation/Insulation CediNcation Floor truss draft stopping finished basement 1,000 sq.ft. EMqWM earess below arade Gas Furnace shut-off within 30 feet or within fine of site ON Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler ReliefValves installed/Heat TraWWAW LeLnp 110 F 77� A , Enclosed Stairs Shestrock Underside minimum W G m .--R Basement stairs dosed rise>4 inches Gsnxp Floor Pitched Ga r(xA /%hour fire door/door closer Duct work Sealed Gas Loge in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc fault Breaker in Bedrooms Flex Gas Pipe Bondina As Built Septic System/Sewer De . Inspection Sticker Site Plan /Variance required. Flood Plain Certification if required Okay to issue C/C or C/O Tem /Permanent " LABuilding&Codes Formzl3ullding&CodesUnspedion Forns\Residen ial Final inspection Form revised_100405.doc;Revised January 7,2008;Revised 6/26/08 Queensbu u�n & Code Enforcement - Residential Final Inspection rY 9 p Office No. (518) 761-8256 Arrive: am/pm De rt:1/0 am/prn Date Inspection request received: Inspector's Initials: NAME: PERMIT#: ZQ LOCATION: DATE: TYPE OF STRUCTURE: _ Comments: 4' Building Number Address visible from road Yes N A Chimney Height/'B"Vent/Direct Vent Location �-?'— —7 _ Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Corn plete/Exterior Finish Complete Platform at all exterior doors _ Handrail 4 or more risers Guards at stairs decks patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off a sed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight §Lkly glazing/Window in stairwells saffebf glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches eight in accessible area Crawl Spaces 18 inch x 24 inch access 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures E Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating �---, Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrodk Underside minimum W Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Gara a fire roofs /%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Are fault Breaker in Bedrooms Flex Gas Pipe Bonding As Buik Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 1 Temporary/Permanent LABuilding&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Forrn_revised 100405.doc;Revised January 7,2008;Revised 6/26/08 Queensbury Building & Code Enforcement - Residential Final Inspection face No. (518)761-8256 Arrive: am/pm Depart:�. .�-�am/pm Date Inspection request received: A Inspector's Initials: 19— NAME: PERMIT#: 2es N w 2� LOCATION: DATE: TYPE OF STRUCTURE: 4T Comments Y ® N/A Building Number/Address visible from road Chimne Hei ht/'S"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors ��`,�►"'�/_� `"` .--•• Guards at stairs,decks, atios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches malfforlIfto Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch-clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade �l Interior privacy!trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: �` 11# ,�. Inter Connected: Battery backup: Carbon Monoxide Detector '" 4 Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .1-150 s .ft.vents .a� 1 � �''" Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade .- Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''/s"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly G j&jagLjZ Sealed or Glass Enclosure inal Electrica maI SurveyPlot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart:--am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: `:_7 7 NAME: PERMIT #: �� �� LOCATION: QS2, _ INSPECT ON: Z TYPE OF STRUCTURE: Y N N/A Rough Plumbing Nail Plates Plumbing Vent J Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum �_L Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head � �- 5 .S.I for 15 minutes nsulation Residential Check/ Commercial Checki �yam"` ZX Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: , , c ---✓�- LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: � 'e+ m/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: < �J LOCATION: INSPECT ON: TYPE OF STRUC Y N NIA Framing COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '%z w 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart: _ m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT #: LOCATION: INSPECT ON: TYPE OF STRUCTURE: _ All, Y N N/A ou h Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head P.S.I for 15 minutes t�Wulation / Residential Check / Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report-revised Nov 17 2003.doc Revised February 15,2005 j w Framing/ Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart:I/ am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: � �`� NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: z 2- zNW> Y INNN/A COMMENTS Laming , 00 Attic Access 22"x 30"minimum F—/04/41 Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams? Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. -- Stairwells 36 in. or more Headroom 6 ft. 8 in. C;j C � Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate I '/z(w) 16 gauge(8) 16D nails each side - Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour OF Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade c a Septic Inspection Report Office No.(518) 761-8256 Date Inspection r quest re e' e . Queensbury Building&Code Enforcement Arrive: am/pm part: _am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's In' is NAME: �_H R�� j E IT NO.: 7�{j C'S-- LOCATION: L y� { s � PECT ON: \(7) RECHECK: Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: -PipingSize Type Building to tank Tank to Distribution Box Distribution Box to Field/Pit Opening Sealed: Y/N/Partial End Cap Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot PI I Y N Engineer Report a As-Built Y N Location of System on Property: Front Rear Left Side Right Side Middle Fro Middle Rear System Use Sta s• Approved Partial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved Last revised 1/6/05 L Septic Inspection Report Office No.(518) 761-8256 Date Inspection req t r ve : Queensbury Building&Code Enforcement Arrive: �p D art: a P 742 Bay Rd., Queensbury,NY 12804 Inspector's Initi s: r NAME: IT NO.: LOCATION: PECT ON: RECHECK: Comments and/or diagram Soil T L a Type of Water unici a' ell Water Waterlines ara is ance ft.Well separation distance ft. ? Other wells: ft. ` Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: ' Piping Size Type Building to tank Tank to Distribution Box Distribution Box field it^ ► P Opening Seale artial End Ca z Location/Separations Foundation to tank Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Pl Y En 'neer Report an As-Built Y Location of System on Property: Front Rear Left Side Right Side Middle Front iddle Rear System Use Status: proved artial Approved and needs to be re-inspe ed,please call the Building&Codes Office Disapproved Last revised 1/6/05 Septic Inspection Reree Office No.(518)761-8256 Date Inspectio Queensbury Building&Code Enforcement Arrive:742 Bay Rd., Queensbury,NY 12804 Inspector's InNAME: ' �� ` 1O RECHECKLOCATION Comments an(/or diagram Soil Type: Sand/Loam./Clay Type of Water: Municipal/Well Water Waterline separation distance Well separation distance Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Y _Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Z- Distribution Box to Field/Pit Opening Sealed: Y/N/Partial P v y�) C) End Caps . k3� -VU p Location/Separations "�'\ � vaev—y� mo CIF Foundation to tank ft. Foundation to absorption Separation of Pits ft. Conforms as per Plot Plan Y N Engineer Report and As-Built Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: roved artial Approved and needs to be re-inspected,please call the Building& Codes Office Disapproved Last revised 1/6/05 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: _am/ll�� epart: m/pm or' 742 Bay Road, Queensbury, NY 12804 Inspects Initials:v NAME: iT : PERMIT#: 4LOCATION: 7 INSPECT ON: 4TYPE OF STRU Y N NIA COMMENTS F ing Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly «�S 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls ,) Metal Strapping for Notches Top Plate 2 n 1 %s (w) 16 gauge (8) 16D nails each side A-7�k Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center C9 j k I Ao9,-:*S (:E� Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour ^j PC) C a V Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection TORMSTraming Firestopping Inspection Report.doc January 28,2003 7- L4_11 H 4 Jr 4_4 - - -T - _ Iq. kLI ail, ILI _44 In v- 1 -1 _ 1. Y­ ­4 DA¢�t,� t�IDEiJGG � �vGTJpbC,. fJ�91G� p. 1 3.0 {,44.0 l f= Sc��F't,• s����a G — 2, 2� �.30 r-25?- IOLO _L040:3 g�-IC : 70 I`5I~ G 0 cep\E(2 (FICT_ 1&08. 2) � r�Ol LCI L& CTA�� 7) 1Or 0,7 �` 1 = (o.7)(I :2)6-O)6.0)(7o) = t)8.v 1p5F cfr L4060 CreP6LJ OI c L-,!4L TO 7/1 2 PlT, _z 60.7& lv,� FOr?, EASE, or- 06-LCOL&Tio"JS e e�cli4a-5 10r63t,?cTl4r....f goof- 5c CFI 1 -CZE 51 Imo►= GLIO✓ LaNO O� 7'/f 2 O� 0 4+EA��2. O✓C'2 �(Lli/fy't';4 t��` ..► �✓D12�' = _1�30# r G� 2. ►�...' 0i4,3 E!2) 9& . 14.st�'5 S ° %coJo Ids; 't n 1� a ' '' ' ) i- . .. ---T--�—�--`�-- �' �� i�r �� 6000 TO rat r b'l 1/3&04k' T���,..�-_►i.�.=•�t�1�-tom.;`' ��� R���� - `72$ �� it�i�. C " L�x�►ft�_ Vic?_ Jt�P �- �D�t.� -JO��`� � L�.r`� �, =��� � �`7 P ��; -�f�►Z I.�iLL�__C.�� �G.>, : �j G-4�.1 �t� i'l>�-t t k.`! 2c2�r-'f 1412 r ZZ ;i r X 1 �` •t� t 51. 17 x 2 = 114. 1611 3607 r ; ' 1� G -c k i F i 3 r F , _- LE E Jt�• Q��i j/�/� ,gtO'� _ 1 SAIL - C,►���1 _ ATO i ^Q3673T1 73 i jDamley 6 34 17 -8 4,11-8 AM .44 SX5. I ' t 7.47 • � 3Xkt� I via_ rra —. E f .-_�•='� a '�=-.,."` .. _ �'' eta= 1 Ica r sxs�` Us i LflOG1A1 ICsI} Ismdwv 7�.o _ ! �!- !1 ( Val - Lld PLXi®! S.1tl� T ( O o a�v.s7ati1 �latea inrta�t 1.7d C I v�f1�Ly .n.3a -J-iZ a419 3e4 W2C � 7w Wrinalsnse 1.45 YC I'll ^03e �* SwF sdn 1 =6 oo RBpErMder YES wrs oee Mm+�(1i„ o FI rb nhs 0L�1 y +*, MIS .S K ►ik9 too s N�hE asip tG RD 2X49PPIWAOP1•f8 Ta�'Mr�014 �IAel,eaamptardver9krtw. DDT!�{AIRD 3 X t gpE Ra,i 9C'�+oRD t� sR dtrat{1y®Fib or�6^0 w erar�r,�. I a5 2Xdr NuQ W1AxI%FFNat, Ax�arN�s,9 j ja lliilertL 9i 1ib&B. 4?70VU-d-a jW cm 8) i MAN glpnna,aflrord Dews 7?,tw..opdsa eh t NeR�ncvLal/NDoid �,xn�9o0bed caRr 5} �slru�r 4a)-cR.e uwe see aNy "'AP CNOFrrr .�-6+77.d-Car�i6F.G��T�at.�-e Yv4?,tlrPwa109.F tin,Psi.�17a2,P.FP4tPS9 � !lLlrCkR�9A k�l d-K T?S 2TZS,HG.a--+i400 VMS �W, NO4� t)v*sq;lu6CET-►6;®Cwpir;hV6R;TGV�a.eME 6006rsA.ow9P;4e1•ass ESP®;wCw-IA MWF9G Pb4a and vadAe tldWeve:!pR Rr17 dpi*wa,WW i and ; wrJeo kA and r4K swwaect urAmf O W=Pbb Ot DU wf.61. d pluwh o iht cnmt;Caa�s'� i f Y �.t•l,tTU 7_.5w1= a "i,d M� 4)"16 rlp1no4bs.ndrw:gredTer0.90gnRs►we4rwr5lsmfdS$.Wu"Owhao CprtftRwMa'_�tEMtla�` 4�)i TW4 hum he b",e'ul bodfer a 7a.affia pft bEdo n chard Na lad n w9h�ry atller lv9 hWOe. '7 8eR!Nt9 a< Sn N ca�idCs`S P'Ja t9 g+lf�iv�ril�wlnQ A�s1rt�1 anB�r rr galn h.r�s..au4drso-��lp,r+►pgd v.11N"rpSNY d eaa'lifgi re�.P.mA. �' ?)N9+4d+rnadr !asnq.q:kfn{lnrdham)at4ueeinheftWoMcaoWocewA116landM19bIlp1�t?1�4t1"1L !S11L�N!at161ttli, CA"&N dit s I I I ��01bo01 1 ! Sul 0009 0SYRON "i GOO'd 91S,t 0 8C 'OO,, '117A I t'929, r 18 STNS S I id;1,J:ILOJ J 1&03673Ty T1 idu1MENP10ST 4 1 Derr-lay L-11'dame—ro o.i,fon a Zed ._ManNsv9i Asa T, g� 944 iias &240 4,11 #T914410 1:53.1I 7.0,r3 4+,i ti C C AXA I i i 4 I I ~, R S I 3 iA �---- d 7G1 53.3 SPACINS 2.9.0 Cal L T dloQ Udall liar PLAN Setae 1103" lr,le8o 1.12 Te 0�1 WOOL) •9.10 W Wi10 3t4, 6Rf 7r, 7I71944 I aaroundRna+r•a7UAb{ LONAWlrv"ta K 1d 00 O167 I VOM74 .p,10 W -IN ya I ca mpbvoolln:r VU w ;74 ! ame M In nh ! =1 SM000/AN01ed �Al) vD. r bUd 24d � wypWl83hSMIL ,IrAR4 aXe M1550Fi.i0 TOPCMOND (Skt7�b6cr436smp�ikM,fxeuptendvaAkaeid NOTCHORD3XABPRIIIOPIAM WTCm%O bcdl dtl4CYlNpk er`14000e'�r g WE" AY,48PFNe.2Ifta C W11118 I R2WVkINWVGt.p.M 1Ni a x I SOP IoIOF I,A3,W 12 x 9&*I140P 1,68 1 MACt)O* (F&A2e) .le1937l046,Me17S.!"0.5$ VAN MWIJ0,400eed care M ` Ma:ui;JI9Je�IT�IWif t01C 7),Ha-ufted cam A) rov 1 Ada.9j'IOeAlovd caw fi.Me1047*4 two 3) FC3tCO� •PSwd uwd C:see tx,y TOP t:H0& JaM76,GCr72e.Goe,523.0�•tra.,�-TiL.w�a1e.lJ J..TN,r H�►7!i 11 V*d;AffiLA 7-MMIrlor,,Wak TY.GL-,kgAt,ECDLYiAptr;Getegary'is Wto 114 efLUDdl MWFRS 3&e WJ 20112;cvjostt lot lord rl9lt&peted;C„d va4tai kt end,l�k exptafi Lu!s>bar^�O1e1.33 pole 1Yb OOLst.lS �Tq►;..:AiC6 7�Pg.T,L/Fwt(!1^4Ut,,,eoewll Pf�i:a Pet{1,6trbal atvr Cnte0aN 1+,map 5;Feebly ltR;G,er•1 ` s)Un0atatced eNaurr�do Awe Deea nea,akie tar thle 4eoipn. 4)THI 4toll rae wm desyoai for I.Od bm go coal lwd!91 Io,e pd ON cmilwKs fig bade. 6?1ds"s hat o0eN"Mod Tara 10,0 pa bollQlry ft-A Rue Ind norccromm WM,Iry hoot(lM bAM. PwAftovchwkilcnr"Aw(AY0m rs)sthmsmkawtvoku Owm alwE,adandlyd471b;mMotjaillJ and ImbupfRlightM. LDAb CAIS�D)anndord I I I i i t�O'd �?S7,# 6��2C �lCiZtC'/L l vG� VSP S3�'S dC1J�'�'31hiGJ �43ST3T7 E'" R' U NPCST": 4k41P �ATAk.ln�lillf!bE.InR�71���prof I 4x4 9�1t 9:fia. i H i ' I el 7.47 i s !� 1. D 3.6t9411 j AS AA y X W V U T q 1! C P i 201, 6— 2X4 11 04L2 arAcING 2-94 e1n ClPi. jr Oa) 9dtB L;a M,ATfi r-.It►+ (TfrIaOL�Lard5raw�u.a5 FlikwIPV" t.;i a" M.N4t) -a-n1 0 1W 120 µ O 1BTMd4 Tcat s,a Lk"Win mu 9,i6 8C all tro�R) •9.91 0 W 1I0 ®Gl I..P Rap Bnsaa fmcr r>ss Ox Ifva(T1.1 d,eo * Ni nt9 QcLL s11.D Cak wm7bt Ili Ila TW CHC RD,i,XA PIN ft3 TOM 5hsalrea araA•g ca t�+apff#:O+�.Rt antl va�t3rals. Rffcx ►W a X4 9P NIL2 40r CJitgb f411d aspBp drtefy a ar r540 sn IRMCI ap, VMS 2xe F1EatF1A-% OTHMS 9 X.4 SPIN NIJ 't;i�llP,TIOFB Obiilts,rV ,tpatl6R f4>,P�17�7;:•a a, P6 6E4 EN•aaB/23.6-0,%■9AH59.6-0,waF�l3i•1.0,7F393/22-SrB,Uu1s9�;f,.6C�1,hrlfai>�4ir4.;=7Ct+z22.h-S,5�5L�l2i..s.9, 'bi, Q.T99l2�6-0 Mg.%HarsAe.19�IMJ1d epos rrax 1_,; pr i lmd nBe d)Fw.�IG mn aBs 5�,t e��ad eaaM�,?arWw3 mm 7),Yx a—s 1 VO4V ad calla 71,ANR-1 asW msd 41,u*•350:, sm Ili,ra asp-d m.rB.asaspald:oat93,R=a�l3sdmoo fij�, 0easaa rd�1k� brd wa s1.�ra�ea am�,ws9dnaxd�..1).w�i4ikao aaft 3),T-604(lda�'U I.o99w me 31 R.aa3i001d�s 33.0="qWd am 3) PURGER, 'p}•Flit Lad Cam QM) roP p.a+�, c�1s C--n e-E M,rrFm7s,w•ri-n,64"76,H4,4*W*W,A-1411,"Pat>rnr..4a.W441,a>•ona,84s--ms, 8[?S Gh?r� FArA�•Sr 3rAAr•9,Y,�•.B,7t.�.�.1,'N+7M�lc Y.lAis-6,U-Va-s,T.i!a•i,S"I�1 Ani9i•9.C}�g,i:'•9�"S WRGf F4tr=afa,�.!►/a►�11, 1.Od1:t V=:iS,n x+,�7 C +•1s6,t L--?aB,J- Hl,t•lB.ta�.lt 7oa4 rt q�lSe ` ,'OTO vMd AfiUi 7•C�oftplK h a3dYG TCal.4apY b3CD1aa1 Opaf1 btegey p; ti;anefae9l B4wmS uabid+t+ld:a c mv.wu ION and ri9hr ;;04 vvtkwl taRrnd i umba oaL+t ss i�D x�±,m; 31 TN6sdeelg2d(at wltro tBrdB in f+e pL�.d 1sa +o1br,Par slud4 t to sktna�gBrmBi�the ismBF.ia6 M!h!i'SRIfd7rt1 0Q19 And QEh1' i 1317ULt Aga 7-W Pr 7DD 90(WON mvr4:AFSL9 WOK Nd 41":C44M 11;E*%PaMWI t&*;Ctd9.1 L'td:allnrid atevr ksrds Illy gun emafdc�d AX 9+h ds M 7Tr ttoww RU hid bath both t� ffd 11a Mad aauah dtaruuahp taia�trrv�aryeurerdwf�s a�enrlurmtvA IhtBbuds, ` AN Opka wa 1.ft4 t�rr�unka a1prrrlrt hone" 1 jo fadWert441lu ema+tllrltmo h9Roro OUldbhvMq, s)4tvsd t9 b a IWV OOsftd Rani am f9aa dr wxdy bparad d9tlsdiii W MOva nwd II,G 410,12hNv* 10 oaett at„da Bpsted stu-0 Co.by �d up�t t1)4s �� * 1sRttY a'bt<P Bbp 1 k 9fNIMILM 5 bapiAt![JO¢tli ld Ohl 0,T 4�IMAtlafrbWait w. upYrst�olM�'dhd>i7 ib upillr dtlahcc 4 ( LOAD"MM SM?*ra 1 I I i �of3iaoo� ��,� �aooa r3�►s[ou �� �z:s f'"' �'o"i��rXY�"` 910-1:90 soot/ZZA T VM P98 S31VS dOlOVdffO SI M:WOa t • °J�i{Gt 1 tJ/.�� i 5- L Permit Number MECcheck Compliance Report Checked By/Date Proposed New York State Energy Conservation Construction Code MECcheck Software Version 3.3 Release lb Data filename:Untitled TITLE:Darnley Residence COUNTY:Warren RECEIVED STATE:New York HDD:7635 CONSTRUCTION TYPE: Detached 1 or 2 Family J U N 13 2005 HEATING TYPE:Non-Electric TOWN OF QUEENSBURY DATE:06/10/05 BUILDING AND CODE DATE OF PLANS:June 11,2005 PROJECT INFORMATION: Renovations&Addition to: Darnley Residence 68 Lambert Dr.,Queensbury,NY COMPANY INFORMATION: Dwellings by Dybas COMPLIANCE:Passes Maximum UA= 198 Your Home= 154 22.2%Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Raised or Energy Truss 715 38.0 0.0 18 Wall 1: Wood Frame, 16"o.c. 1294 21.0 0.0 67 Window 1:Wood Frame,Double Pane with Low-E 107 0.330 35 Door 1: Solid 18 0.093 2 Floor 1: All-Wood Joist/Truss,Over Unconditioned Space 728 21.0 0.0 32 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the Pro State Energy Conservation Construction Code requirements. /Designer C) Date Cs' �ERED AR, D. a � x < or 4 MECcheck Inspection Checklist Proposed New York State Energy Conservation Construction Code MECcheck Software Version 3.3 Release I DATE:06/10/05 TITLE:Darnley Residence Bldg. fit• 1 Use Ceilings: [ ] 1. Ceiling 1:Raised or Energy Truss,R-38.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. Above-Grade Walls: [ ] C 1. Wall 1:Wood Frame, 16"o.c.,R 21.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Wood Frame,Double Pane with Low-E,U-factor: 0.330 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: Doors: [ ] 1. Door 1: Solid,U-factor: 0.093 Comments: Floors: [ ] 1. Floor 1:All-Wood Joist/Truss,Over Unconditioned Space,R-21.0 cavity insulation Comments: Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] ( Recessed lights must be Type IC rated and installed with no penetrations,or Type IC or non-IC rated installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials and 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions [ ] Materials and equipment must be identified so that compliance can be determined. [ ] ( Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. 1 k [ J I Supply ducts in unconditioned spaces must be insulated to R-11. [ ] I Return ducts in unconditioned spaces(except basements)must be insulated to R-2. I Insulation is not required on return ducts in basements. I Duct Construction: [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics I (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. I Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g. (500 Pa). [ J I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ) j Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] ( Air filters are required in the return air system. [ ] I The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. I Electric Systems: [ ] I Separate electric meters are required for each dwelling unit. Fireplaces: [ ] ( Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] I Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. I Service Water Heating: [ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the I water heater has an integral heat trap or is part of a circulating system. [ J I Insulate circulating hot water pipes to the levels in Table 1. I Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. i I Swimming Pools: [ ] I All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. I Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 105 T or chilled fluids below 55°F must be insulated to the I levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipe& Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only)