blower door test �.00N .
NEBPA BLOWER DOOR FORM
Home Energy Experts
lTortlr East Building.
Perlorrar mice Adr-isors
51 S.ZU0..9941
Contractor: Clute Enterprise Inc Date: 5/30/2018
Contractor Address: 6 Holden Ave City: Glens Falls State: NY Zip: 12804
Phone# 518-793-7277 Email:
Location tested: 86 Eagan Rd City: Queensbury State: NY Zip: 12804
Customer Name:
Phone# Email:
Ventilation requirements:
Volume= (Height x Living)+(Height x Basement) X 3/60 =ACH per Hour
Volume: 18356 x 3= 55069/60 = 917.80CFM @ 50
Maximum CFM 50 to achieve less than 3 ACH= 917.8
Blower Door Diagnostics: Ring Open
Inside Temp: 75 Baseline Pressure -49.3 Pa. �A
Outside Temp: 80 Fan Pressure -24 Pa. �B
C
Actual Flow @ CFM50 = 904 cfm@50
CFM@50 x 60/Volume = 2.95 ach
New York State Requires builders run a blower door test on new residential
buildings to ensure a maximum air leakage of three air changes per hour(ach50).
*ACH test results are considerably lower than building standards. Mechanical
Ventilation is highly recommended.
*As a reference, Energy Star homes must come in at.35 ACH naturally to qualify.
Blower Door testing performed by:
North East Building Performance Advisors 31
7 Rocky Ridge rrrrrr„1t�1rJV171,4
Warrensburg, NY 12885 .
518-350-2941
BPI, GoIdStar-