Loading...
E14838506.20-0014818 Soundside Rd Edenton, NC 27932 Trenco Re: The truss drawing(s) referenced below have been prepared by Truss Engineering Co. under my direct supervision based on the parameters provided by Bellevue Builders Supply. September 9,2020 Lassiter, Frank Pages or sheets covered by this seal: E14838506 thru E14838506 My license renewal date for the state of New York is November 30, 2021. 20-0014 Hilltop/ 160 Aviation Rd IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD20601SafetyInformation WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 818 Soundside Road Edenton, NC 27932 Job 20-0014 Truss T3 Truss Type MONOPITCH Qty 12 Ply 1 Hilltop/ 160 Aviation Rd Job Reference (optional) E14838506 8.330 s Jul 22 2020 MiTek Industries, Inc. Tue Sep 8 16:13:03 2020 Page 1BellevueBuildersSupply, Schenectady, NY - 12306, ID:1l8OnB2x3JBqckqB8ztb1KzwlSO-HOlLObtnJmfFDa5gulgPcP7TFCwtnNS8ZooszWyfeQU Scale = 1:59.3 1 2 3 4 5 6 10 9 8 7 15 16 17 18 5x6 5x6 MT20HS 6x10 5x6 4x6 3x4 2x4 3x4 3x5 4x6 9-3-0 9-3-0 18-2-9 8-11-8 27-5-9 9-3-0 9-3-0 9-3-0 18-2-9 8-11-8 27-5-9 9-3-0 1-2-010- 3-1410-3-144.00 12 Plate Offsets (X,Y)-- [1:0-8-3,Edge], [5:0-2-4,0-1-8], [6:Edge,0-3-8], [7: 0-4- 4, 0-2-4]LOADING ( psf) TCLL Ground Snow=50. 0)TCDL BCLL BCDL 38.5 10. 0 0.0 * 10.0 SPACING-Plate Grip DOL Lumber DOL Rep Stress Incr Code 2- 0- 0 1. 15 1. 15 YES IBC2015/TPI2014 CSI.TC BC WB Matrix-MR 0. 96 0. 93 0. 99 DEFL. Vert( LL)Vert( CT)Horz( CT)in 0. 23 0. 39 0. 11 loc)10- 13 8- 10 7 l/defl 999 836 n/a L/ d 360 240 n/a PLATES MT20 MT20HS Weight: 138 lb FT = 20% GRIP 197/144 148/108 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1- 9: 2x4 SPF 1650F 1. 5E WEBS 2x4 SPF No.2 SLIDER Left 2x8 SP No. 1 -x 3-0-0 BRACING-TOP CHORD Structural wood sheathing directly applied, except end verticals.BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.WEBS 1 Row at midpt 6-7, 3-8 2 Rows at 1/3 pts 5-7 REACTIONS. (size)1=0- 5-8, 7=0-3-7 Max Horz 1=383(LC 6)Max Uplift 1=-172( LC 6), 7=-321(LC 6)Max Grav 1=1716( LC 21), 7=1996(LC 14)FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 ( lb) or less except when shown.TOP CHORD 1-3=-3079/295, 3-5=-2032/148, 5-6=- 283/140, 6-7=-560/130 BOT CHORD 1-10=-579/2803, 8-10=- 579/2803, 7-8=-318/1828 WEBS 3-10=0/330, 3-8=-1294/285, 5-8= 0/ 694, 5-7=-2239/397 NOTES-1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp C; Pr. Enclosed;MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1. 33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow); Category II; Exp C; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf.7) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except ( jt=lb)1=172, 7=321.9) Load case(s) 21, 22 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss.10) MULTIPLE LOADCASES – This design is the composite result of multiple load cases.11) User moving load cases exist: Review the load cases for details.12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back ( B).LOAD CASE(S) Standard Except: 21) 1st User Defined Moving Load - Dead + Snow (balanced): Lumber Increase= 1.15, Plate Increase=1.15 Uniform Loads (plf)Vert: 1-6=- 97(F), 7-11=- 20(F)Continued on page 2 1-10-12 APPLY 2 X 6 X 6' SPF/DF/SP NO.2 SCAB TO ONE FACE OF TRUSS AS SHOWN. ATTACH WITH (0. 131" X 3") NAILS: 2 ROWS: SPACED @ 3" O. C. USE 2" Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD20601SafetyInformation WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 818 Soundside Road Edenton, NC 27932 Job 20-0014 Truss T3 Truss Type MONOPITCH Qty 12 Ply 1 Hilltop/ 160 Aviation Rd Job Reference (optional) E14838506 8.330 s Jul 22 2020 MiTek Industries, Inc. Tue Sep 8 16:13:03 2020 Page 2BellevueBuildersSupply, Schenectady, NY - 12306, ID:1l8OnB2x3JBqckqB8ztb1KzwlSO-HOlLObtnJmfFDa5gulgPcP7TFCwtnNS8ZooszWyfeQU LOAD CASE(S) Concentrated Loads (lb) Vert: 16=-133 22) 2nd User Defined Moving Load - Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-6=-97(F), 7-11=-20(F) Concentrated Loads (lb) Vert: 17=-133 PRODUCT CODE APPROVALSLATERAL BRACINGLOCATIONIndicates location wherebearings( supports) occur. Icons vary butreaction section indicates jointnumber