Loading...
elevator planning guide c 049 Z 20 tl . , , . • NoRtheign. LIFs a...ti ! ...,, . i - \ .,,,. I, • -, : 1... ,' 1 GUIDE Gil PLANNING . . ‘ t . • - . " . \ t • . t - • t. t . . . t GliOCT 06 2020 U .. . . _ i ,. .-, ' • '-', . s - , • i ' TOWN OF QUEENSBURY --- i ___- :- .: BUILDING&CODES - _....------ - LtE • - Roped Hydraulic Elevator . . t\1 i NORTHERN LIFTS ELEVATOR LUXE- 16; HYDRAULIC ELEVATOR PLANNING GUIDE PAGE 2 yyy (it ��1 We are a proud member of the Accessibility Equipment Manufacturers AE•M\ Association. This symbol assures you of our commitment to high quality ACCESSIBILITY EQUIPMENT and accessibility to everyone. MANUFACTURERS ASSOCIATION ° 4,,, We are also proud members of the National Association Of Elevator Contractors. .N� This symbol assures you of our commitment to high quality and accessibility ®C,-,3<. The National Association of Elevator Contractors is the premier association representing the elevator industry. Mission Statement YORK MADE IN NEW Our company's mission is to supply and service products that meet STA or exceed our customers'expectations of high quality,value, delivery 5T�1�'E and longevity.Our success is a direct reflection of our employee's in- volvement and commitment to excellence. We strive to continuously improve our products to ensure meeting the future requirements of our customers and facilitate competitive growth. Table of Contents Introduction&Planning Steps 4 Design Features of Hydraulic Technology built on T Rails 5 Mechanical Illustrations of T Rail 6 Rail Backing Detail 7 Hoistway Elevation View with T Rail 8 Elevator Pit Detail 9 Machine Space&Controller Location .10 Control System .11 Hoistway Construction Specifications 12 Hoistway and Car Size Requirements 13 Electrical Requirements 14 3 x 5 Rule 15 NORTHERNl LIFTS ELEVATOR COMPANY Lc,,[/�E5�0 HYDRAULIC ELEVATOR PLANNING GUIDE PAGE 3`+ Introduction This Planning Guide is to be used as a reference to determine parameters of installation and steps taken to achieve a proper elevator installation.This guide may be used by the architect,contractor, dealer or home owner.The information in this guide is intended as an overview. Each installation will have job specific specifications that must be followed. Do not attempt to construct a hoistway on this information. Elevator installation is to be done by an authorized elevator contractor, and in accordance with installation instructions provided by the manufacturer. Installa- tion must also be in compliance with requirements of the National Electric Code, American Society of Mechanical Engineers safety code,and state and local building codes. Northern Lifts Elevator Company strives to meet the requirements of ASME-17.1 National Elevator Code for residential elevators. Northern Lifts Elevator Company,LLC, elevators manufactured and installed under the proper parameters are under warranty for up to 3 years. Manufacturer is not liable for any equipment not installed in compliance with these codes. Northern Lifts Elevator Company reserves the right to modify the design,technical specifications and dimensions of the products shown in this document. Planning Steps Congratulations you have chosen a hydraulic drive system. Please complete the steps below to finish creating your new elevator. 1 - Select rail system. 2 - Size drive system for travel range,layout machine room,and location. 3 - Choose control features and plan for electrical requirements. 4 - Address national,state,and local code requirements. 5 - Determine hoistway size,car size,layout configuration and available options. Northern Lifts will help you in determining the available design options: cab style,car operating panels,hall stations,phone boxes,handrails,light fixtures,and gates. 6 -. Obtain and follow site specific field drawings..Forward all necessary documents to contractor/builder,architect,and structural engineers. Use job specific drawings while building hoistway,doorways, machine room,and any other construction related to the elevator. 7 - Coordinate with you to install your new elevator. NORTHERN LIFTS ELEVATOR LLIX# y lv HYDRAULIC ELEVATOR PLANNING GUIDE PAGE 4 Design Features of Hydraulic Technology Built onT Rail • Design Built on 8 LBS.T Rail System • Each Rail Section is 118" in Length, Brackets Spaced @ 60" Maximum Intervals • Durable Cantilever Sling Design • Microprocessor Based Control System • Three or Four Coil Valve • Tape Reader Locates Floors with Magnetic Sensor • Sling Movement Translates Through Roller Wheels .N: Iii. NORTHERN LIFTS ELEVATOR LUXE- �,v HYDRAULIC ELEVATOR PLANNING GUIDE PAGE 5 • Mechanical Illustrations of "T" Rails ' I IV,. .trit IIII 1 011 : '' '1;f1 11111i . k1171 f I III 202 LBS.ill AXSHEARJ— m 1 635 lbs. MAX.TENSION 8 LBS.PER FOOT COMMERCIAL ELEVATOR RAIL NORTHERN LIFTS ELEVATOR LUXE—/ry 2 HYDRAULIC ELEVATOR PLANNING GUIDE PAGE 6 Rail Backing Detail for the LLXE- TOP PLATE Typical layouts shown -TRuss here may vary from GLUELAM OR your actual hoistway. PARALLAM BEAMS The purpose of these layouts are for a general . understanding.Please OVERHEAD refer to the job specific CLEARANCE Elevator drawings and BOTTOM PLATE specifications that will HOISTWAY, be provided by Northern OPENING Lifts Elevator. FLOOR JOIST • HEADER STUD FLOOR HEIGHT (Note that in cetain instances, the rails will not be centered in HoisTwnY the hoistway,check the plan view OPENING shop drawings for verification.) PIT FLOOR CENTER LINE TOTAARL OF RAILS TRAVEL 15" 15" DOORWAY V / EXAMPLE OF A ROUGH r FRAMED HOISTWAY I PIT I WITHOUT DRYWALL (2) 5-1/2" 14"/16"or(2)3-1/2 x 18"/20"gluelam wood beams, — ParaIx!ams,no LVL's. Width of beams required will be. determined by the distance between top&bottom plates on each floor,greater distance requires the wider beams. These drawin s de ict 4 9 puillll41P ;�:��:i;,, sample construction MINIF__ only. It is the respon- III I sibility of the installer/ EXAMPLE N OFTYPICAL. contractor or engineer LAYOUT i 1 to design and specifiy - structural supports. All construction to PIT be in compliance with local codes. -P11 NORTHERN LIFTS ELEVATOR L,LI/l.E- ,f6:i HYDRAULIC ELEVATOR PLANNING GUIDE PAGE 7 Hoistway Elevation View with T Rail Example of Hydraulic Elevator Required Overhead Heights • Inside Cab. 6'10" 7'0" 7'4" 8'0" Dimension Minimum 8'0" 8'2" 8'6" 9'2" Overhead * Custom sized cabs will alter these This is a graphical representation of a hy- dimensions.Northern Lifts will provide draulic elevator on T rail which offers a total you with the appropriate dimensions. Please contact your us to acquire of five or six stops(based on controller alternate layouts. package),and a travel distance up to 50 feet. Elevation Rail Layout and Jack Calculations 1 _ 1__ _ _ 27-1/2• r� o f , DISTANCE 14-1 RAM yl pETWEEN I RAM "GUIDES HEADER � 1C L i TO CAR FRAME MINIMUM PISTON INSIDE CAB OVERHEAD STROKE DIMENSIONS PISTON I 1 \IIPROJECTION TOP FLOOR 12° - BELOW TOP J - i _ ' OF CYLINDER OVERALL -CYLINDER 1.� HOISTWAY LENGTH OVERALL J r — EQUIPMENT - HEIGHT TOP JACK BRACKET HEIGHT - V • TOTAL `---I TRAVEL PEDESTAL PEDESTAL BRAKET HEIGHT HEIGHT RAIL BRACKET TYPICAL 0 J L FIRST j.. FLOOR I . .--.. .. I 1 .. Rail Calculations PIT DEPTH 12°PREFERRED PIT DEPTH 10°MINIMUM Rail Length=Hoistway-1" PIT DEPTH 18'WITH BUFFER SPRINGS MINIMUM NORTHERN LIFTS ELEVATOR LC.[/l.E5 •V HYDRAULIC ELEVATOR PLANNING GUIDE PAGE 8 Elevator Pit Detail for the LL1XE- The drawing below is to be used only as a guide in constructing the elevator pit.Consult with your Architect and or Engineer when dete- mining the design and load requirements of the pit.Site specific con- ditions may require additional engineering.Also check with the state, county and local authorities having jurisdiction for any other below grade construction requirements. Wall T "Drywall Wall (Not to Scale) p... • ,a•. a l ', ' y' 12"Minimum Depth Pit floor surface must '�; d• be level and smooth ;a #4 or#5 Reinforcing rods @12"O.C.max. 8"-10"Minimum Thickness 3500 PSI Concrete Designed to withstand a load of 8,000 lbs. Li LUXE NORTHERN LIFTS ELEVATOR LLlx�- �lli HYDRAULIC ELEVATOR PLANNING GUIDE_ PAGE 9 Machine Space & Controller Location Typical Hydraulic 1. The Controller requires minimum clear Elevator Layout space of 36"x 30"located directly in front of the controller(refer to illustration). 2. A lockable service disconnect must be 111411t placed within sight of the controller and must be easily accessible,from the latch side of the doorway(if door is present). 3. Controller space must be provided for bill the operating equipment that meets National Electrical Code clear space 34requirements and all local codes. Con- \ trol space must contain a convenience outlet and light with switch.Tempera- \ tures must be maintained between 60°- 110°F and must not be exposed to the elements(with a relative humidity not to —136"h- {14-1/2"I exceed 95%). / ONTROLLER ER SIZE 20"x20"x7" 4. Consult with Northern Lifts Elevator for / ,...:, layout dimensions. 1 I30-3/4"I o•.'•. 30" -_•: :: aulLDour 5. Northern Lifts may use different power units and or equipment based on specific / DISCONNECT] project needs or limited space applications. REDUCED SIZE DEDICATED MACHINE CLOSET 48"I.D. T '" .M! COWEROLENCLOSUREIMI®I ELEVATOR- r— —aaToa . DS""NOCI HYUMUUC 20" POWER UNIT •3 POLE FUSED,LOCKABLE 73•Dla. I.D. DISCONNECT SWITCH 48-60-Tal DiDOSFD QII➢!G I�dOSFaMIU SVOKIlnlil Dort 1 °v»oWM 3SI WX6.8h MIN.SELF-CLOSING,SELF-LOCKING DOOR. NOTE:THE MACHINE ROOM/CLOSET MAY BE PLACED ON ANY LEVEL OF THE HOME ADJACENT TO THE HOISTWAY.IF THE MACHINE ROOM OR CLOSET CAN BE LOCATED REMOTE UP TO 30 FEET AWAY FROM THE HOISTWAY ON ANY LEVEL.IF THE REMOTE OPTION IS CHOOSEN,ADDITIONAL COST SHALL BE INCURRED. k' r �] NORTHERN LIFTS ELEVATOR LUXE-y , Qi HYDRAULIC ELEVATOR PLANNING GUIDE PAGE 10 Control System - Hydraulic Elevator Our Premium American Built Control System Microproccessor Based Field Programmable Simplified Servicing Fault and trip count feature Conforms to UL508A,ASME Al 7.1 A,ASME A17.5 Included Elevator Equipment PUMP UNIT EQUIPPED WITH CONSTANT DISPLACEMENT ROTARY SCREW PUMP POWERED BY 2.5,2.9,OR 3.5 HORSE- POWER,230 VOLT SINGLE PHASE MOTOR. OIL TANK REQUIRES APPROXIMATELY 30 GALLONS OF AW-32 OR 68 HIGH GRADE HYDRAULIC OIL. VALVE TWO SPEEDS FOR SMOOTH STARTS AND STOPS. WORKING PRESSURE BETWEEN /11 ,.. 250&750 PSI AT 5-8 GPM. \ 110017-1 1. 1Ca li STOPPING DEVICES / :;�(® MAGNETIC TAPE READER EMI INTERLOCK \� FOR LEVELING ACCURACY& TOP FINAL LIMIT SWITCHES. GALTYPE N ® INTERLOCK HOISTWAY DOOR INTERLOCKS EMI or GAL TYPE"N" REQUIRED AT EACH OPENING TO PREVENT HOISTWAY OR ELEVATOR ACCESS AT ANY DOOR OTHER THAN WHERE THE CAR IS LOCATED. PINORTHERN LIFTS ELEVATOR LUXE- v HYDRAULIC ELEVATOR PLANNING GUIDE PAGE 11 Hoistway Specifications - Hydraulic Elevator ATTENTION OWNER AND OR CONSTRUCTION CONTRACTOR: Job specific documentation will be provided by Northern Lifts Elevator from which to construct the hoistway. All Elevator and Hoistway Requirements to be verified and or completed by the Owner,Contractor,or Others prior to elevator installation by Northern Lifts. 1. Electrical Requirements All high voltage electrical work is to be completed by a Qualified Electrician.See page 14 for electric requirements by others. 2. Unfinished/Un-installed Door-At the two lowest levels leave the hoistway doors and assoiciated framing be left unfinished/un-installed to better accommodate the elevator installation equipment and to prevent accidental damage to door and framing. 3. Plumb and Square Hoistway-Hoistway must be plumb within 1/8 inch per 10 ft.of height and square at any point within 1/4 inch based on difference in diagonal measurements. 4. Supportive Structure-Structure must be capable of supporting the appropriate loads. Local engineering support is recommended. 5. Telephone Connection-Code requires a telephone connection to the elevator car; therefore, a phone line must be installed leading to the controller. 6. ASME 17.1 Section 5.3-Hoistway to be constructed in accordance with ASME17.1 section 5.3 and all local codes.. 7. Hoistway Door Security(Interlocks)-All hoistway doors require interlocks as well as a door handle and a latch seta Interlocks will be installed by the elevator installers. Northern Lifts recommends the use of solid core doors&or fire rated doors if required. 8. Hoistway Requirements-Any operating equipment must meet National Electric Code and all local codes. Machine space must have a light switch and a convenience outlet. Temperature must be maintainable between 60°-110°F and must not be exposed to the elements(with a relative humidity not to exceed 95%). 9. No Alterations-Any alterations to the equipment without;written authorization by Northern Lifts Elevator Company,LLC will void all warranties. 10. Pit Floor Strength-A pit floor must be designed to withstand a load of 8,000 lbs. When used,concrete must be a minimum of 8"thick and rated at 3500 PSI. 11. Rated Load-Elevator system is rated for maximum capacity when installed. Additions or changes to the flooring material,walls,trim,base,and/or permanent decor added to elevator car must be subtracted from the car capacity. 12. Verify Code Requirements-Verify all national,state,and local code requirements are all met before installation.This is the sole responsibilty of Others. NORTHERN LIFTS ELEVATOR LUXE- 4, HYDRAULIC ELEVATOR PLANNING GUIDE Page 12 Hoistway and Elevator Car size requirements Construction Notes: • Use specified rail supports framed into the wall sytem. • All measurements on the Elevator Shop Drawings are finished dimensions. Finished dimensions include drywall,plaster and paint. • A maximum distance of 3"is allowed between the closed hoistway door and the outer edge of the landing sill.(See the 3 x 5 Rule on page 14) • Determine height of hall station per local code and ADA requirements. • Rough frame door in place with an extra inch of space on each side of the door to allow for minor adjustments when completeing the door installations. The example below shows the maximum and minimum sizes-for hoistways and elevator cars rated up to 1000 lbs.The car is shown with the standard accordion saftey gates. Finished • Hoistway 52-1/2"Minimum 1-1/4"Max. 65-1/2" Maximum 1-1/4"Max. 1/2"Min. 1/2"Min. u".eta"N MINA.etwA i o r 10„ Finished P q 2 Hoistway , 1 , 46-1/2"Minimum n - *50"O.D.Min. 64-1/2"Maximum I I (63"O.D.Max.) I I 32"O.D.Min. I I I (50"O.D.Max.) I 3 4 n L - VARIABLE • * Single Opening 43-1/4"O.D.(Outside Dimension) Minimum(rail is not centered in hoistway) NOTE: 1) Minimum 1 2 dimensions reflect rail centered in hoistway 2) T Rail minimum 1 2 dimension for car without a gate recess is 40"O.D.(outside dimension) Car Opening Configurations and Coding RAIL F 1-The 1 2 is the side on which the rail is attached. 1" 2 2-The first letter refers to the attachment location of the gate. 3 4 3-The second letter refers to the location of the strike plate. 4-If present,the third letter"R"denotes a recesssed gate. RAIL _ Example: 13R 24R 1 Opposite 2 First Gate-13R Second Gate-24R Left sane side Right SameSide ii Openings ii Opening Opening 1 gate attachment 2 gate attachment 11 13R 24R ii 3 4. 3-strike plate 4-strike plate CODE A CODE e R-recessed gate R-recessed gate II- Front t Opposite Right Adjacent Left Adjacent Front Opening Openings 90°Openings 90°Openings Opening CODE C CODED CODE E CODE F CODE G • Sim • LUXE-r NORTHERN LIFTS ELEVATOR .L, - i�itZ HYDRAULIC ELEVATOR PLANNING GUIDE PAGE 13 Elevator Electrical requirements By General Contractor/Owner/Electrician: Your qualified electrician and phone installer shall provide the following equipment: Main disconnect- One(1)dedicated 208-230V single-phase power supply to a 30 Amp fused disconnect switch with Two(2)20 Amp time-delay"FRN"fuses,(if voltage is lower than 208V or greater than 240V,a buck-boost transformer system is required). Lighting disconnect-One(1)dedicated 110V to 120V 15 Amp fused disconnect or circuit breaker for the independent cab lighting circuit. Telephone line-One(1)telephone line supplied to the elevator control cabinet. Below are recommended manufacturers for the fused disconnect located in the machine room. Square D Main disconnect: 230V single-phase disconnect model#D321 N 240V-30 Amp with In addition,two each-250V,20 Amp,&one 250V,3 Amp.All are to be FRN time delay fuses. Separate Lighting disconnect-120V 15 Amp fused disconnect or circuit breaker. Siemens Main disconnect:230V single-phase disconnect model#GF321 N 240V-30 Amp with In addition,two each-250V,20 Amp,&one 250V,3 Amp.All are to be FRN time delay fuses. Separate Lighting disconnect-120V 15 Amp fused disconnect or circuit breaker. Cutler Hammer Main disconnect:230V single-phase disconnect model#DH321NGK 240V-30 Amp with In addition,two each-250V,20 Amp,&one 250V,3 Amp.All are to be FRN time delay fuses. Separate Lighting disconnect-120V 15 Amp fused disconnect or circuit breaker. NOTE:Northern Lifts Elevator Company does not provide power cable to disconnects in the elevator machine room.Recommended manufacturers for the 230V single phase 30 amp circuit breaker at the main distribution panel(and the distribution panel itself)are listed above. If a back-up generator is available,it is recomended that both elevator electric circuits be supplied from the Generator distribution panel,provided that it produces the correct amount of power to run the elevator.All electrical work and wiring must comply with applicable codes.All of the above electrical requirements are for general reference for most projects.Custom projects with specific requirements may change or add to the above listed equipment. Hoistway Lights&Service Outlet: Two dedicated crcuits one for lights,light switch the other for a GFCI service outlet are to be installed in the hoistway.The GFCI service outlet,light and light switch are to be installed in a lower corner area of the hoistway,24"above the pit floor.Wall lights are to be installed vertically in the hoistway at specific locations.Lights are only to be controlled by the switch in the hoistway. Machine Room/Closet Light&Service Outlet: Two dedicated circuits,one for a light with light switch,and another for a GFCI service outlet,all are to be installed in the machine room/closet. !T� �al NORTHERN LIFTS ELEVATOR LUXE- 4p HYDRAULIC ELEVATOR PLANNING GUIDE PAGE 14 Residential Elevator 3/4" & 4" Rules ASME ANSI A17.1 Safety Code for Elevators and Escalators Part 5.3 Private Residence Elevators. Rule 5.3.1.7.2 & 5.3.1.8.3 of the above referenced code states: `The distance between the hoistway face of the hoistway doors and the hoistway edge of the landing sill shall not exceed 19mm (0.75 in.)for swinging doors". & (c) "Swinging Hoistway Doors and Car Gates. Where swinging hoistway doors and car gates are used, the space between the hoistway door and the car gate shall reject a 100 mm (4 in.) diameter ball at all points". Note:Concrete block/masonry shafts and some commercial metal door frames can often create 3/4"X 4" Rule violations. -• IRED:MINIMUM OF 2-1/2"W.x 11"H.RECESSED POCKET AREA IN PANEL TO ALLOW SPACE FOR LOCK IN UPPER CORNER ON STRIKE SIDE JAMB. EMDL ,'..Jt,, ** `�? - LANDING DOOR r�LANDING DOOR,CAN door lock �s� VARY IN THICKNESS 1-3/4"TO2"THICK kL � l TO REDUCE ADDED TYPICAL - PANEL THICKNESS I Q � � 45' .��I1 HOISTWAY SIDE OF 2x4 wall e DOOR THICKER AND OR SP CE FILLER PANEL 2x4 wall DOOR SPACE FILLER PANEL(S) "At"Max 4"Max '' ''''• Finished ••••:••I •:•••.;• C HOISTWAY FINISHED Edge Flring/Sill 1/2"-1-1/2" Gt )F • •. 11 ELEVATOR CAB shall not Running No Trim or casing ••''. .•..'• .1 ACCORDION GATE exceed 3/4" Clearance on hoistwayside •':•' '••..• from back of Elevator Cab Min./Max. of all doors. •••0:;••• door or extend • w 4" MAXIMUM FROM _ :•;; Q I DOOR TO CAB GATE beyond face / • ► AND OR CAB IN THE of shaft wall surface Top View • In CLOSED POSITION FINISHED EDGE OF 3/4"MAXIMUM FLOORING TO FLUSH i. :. i FROM DOOR TO * NO TRIM OR CASING. WITH THE FINISHED EDGE OF FLOOR/SILL Do not install any door casing/trim, WALL SURFACE. :•'':''] ji„ fill and or flat tape to jambs. House Side Elevator Cab Floor •:''•••••••••.• of Elevator ** Landing swing doors can be increased I � in thickness to reduce or eliminate 4-- the need of adding panel(s).Pocket/ Recessed areas must be created for 7 door lock and lockset installation. RUNNING CLEARANCE 1/2"TO 1-12" �v Note:An out of plumb shaft will greatly (Rule 5.3.1.4.2) affect running clearances and exacerbate Side View the 3/4"x 4"Code Compliance Issues. The 3/4"x 4" Rule is a code requirement. Northern Lifts Elevator Company, LLC takes care in ensuring safe use of the elevator equipment and as a policy wants to make sure all Builders, Architects, Developers, Owners/Users are aware of and adhere to this National Code. THIS IS A SAFETY ISSUE. T'll d NORTHERN LIFTS ELEVATOR LUXE- , HYDRAULIC ELEVATOR PLANNING GUIDE PAGE 15 • Notes: t-Ti,,,,l, !T� r NORTHERN LIFTS ELEVATOR L1i 7C -54 i& HYDRAULIC ELEVATOR PLANNING GUIDE PAGE 16 Notes: A NORTHERN LIFTS ELEVATOR LUXE-E-- ,i HYDRAULIC ELEVATOR PLANNING GUIDE PAGE 17