Loading...
2005-622 TOWN OF QUEENSBURY 742 Bay Road,Queensburv,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20050622 Date Issued: Thursday, September 29, 2005 This is to certify that work requested to be done as shown by Permit Number P20050622 has been completed. Tax Map Number: 523400-295-010-0001-031-002-0000 Location: 1088 WEST MT. Rd Owner: DAVID LEHMANN Applicant: DAVID LEHMANN This structure may be occupied as a: Residential Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050622 Application Number: A20050622 Tax Map No: 523400-295-010-0001-031-002-0000 Permission is hereby granted to: DAVID LEHMANN For property located at: 1088 WEST MT. Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: DAVID LEHMANN Residential Alteration $5,000.00 RICHELLE IVES-LEHMANN Total Value $5,000.00 1088 WEST MT. Rd QUEENSBURY, NY 12804-0000 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2005-622 400 SQ FT RESIDENTIAL ALTERATION (CONVERT GARAGE TO LIVING SPACE) $40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday, August 16, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T of Quee bury; Tuesday,August 16, 2005 SIGNED BY for the Town of Queensbury. Director of Buildin &Co Enforcement Permit No. Building&Codes Office-Department of Community Development-Town of Queensbury Fee Paid 742 Bay Road, Queensbury,NY 12804 Recreation Fee Dave Hatin,Director codes@queensbury net Phone: (518) 761-8256 FAX: (518) 745-4437 Principal Structure Building Permit Application Application & Plans subiect to review before issuance of a valid permit for construction fa Instructions: A permit must be obtained before beginning construction. No inspections will be made until the applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the application form. / Applicant/Builder °I, I ►" i� l i r , Z t i2i J �; Owner: Address: Address: G v irk ., it Home Phone: Home Phone: Email Address: Email Address: Cell Phone: 22 y qW, Cell Phone: FAX Phone: ---- FAX Phone: Person responsible for supervision of work with respect to building and codes compliance: Name: )c� r� (. f�:,��.�. Address: Phone Location of proposed construction: Lot No. Legal Address: r_ L.>{, 11l •� 1f Tax Map Number: 'I) Z �LIIV) ?Z_049 ' Ul.0 Subdivision Name: - Estimated Cost of Construction: $�S, Proposed construction is for: Residential Use _Commercial Use Name of Business: -- cur, 0 5 2005 If proposed construction is an addition,what will use of new addition bee__65-f Wt,: New Addition Alteration Proposed Construction 10 Floor 2^d floor Other Total Proposed structure (Occupancy Type) Sq. Ft. sq.ft. Sq.Ft. Square feet Height Ft.&in. Single-family Dwelling Two-Family Dwelling Townhouse Multifamily Dwelling Number of Units: Office Mercantile Manufacturing Other: Attached Garage 1, 2, 3 Type of Heating System: Electric, Oil, Gas, Wood, orced Hot Air, Baseboard, Other: Is a fireplace and/or woodstove being installed, please refer to a separate application. ,Yes ,L No Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review. The Building and Codes Office will allow commencement of your proposed project only after issuance of your permit. Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all new construction. Date: Applicant/Builder Signature• The application of dated is hereby approved and permission granted for the construction, reconstruction or alteration of building/and or accessory structure as set forth above. n Date: ``' Authorized Signature: L:\Sue Hemingway\Building.Permit.FOR MS\Principal structure Permit Application.doc V:12/14/04 I Queensbury Building & Code Enforcement - Residential Final Inspection l — 1 Office No.(518)761-8256 Arrive: am/ a art: ��am/pm Date Inspection request received: 7 6S Inspector's Initials: 7�n NAME: r\I cV PERMIT#: ©S- -�,ZZ LOCATION: _C�r52_LVl_ DATE: _ TYPE OF STRUCTURE: Comments Y N N/A Chimne 'Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent throw h roof minimum 6" Roof Complete/Exterior Finish Com lete Guard 30 in.or more(a)stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum ''/2" Gypsum Grade awa from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tern 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safe lz /Window in stairwells safety glazing Interior Smoke Detectors: Every level: i Every Bedroom: Outside every bedroom area: Inter Connected: / Batter backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fireproofing/'/4 hour fire door/door closer Duct work Seated properly _ Gas Logs in Sealed or Glass Enclosure Attic access 30 in,x 22 in.x 30 in.(ht.)In accessible area i Crawl Spaces 18"x 24"access, 1 s . ft,150 s . ft.vents Building No./Address visible-from road Final Electrical -z-I (gri— V Site Plan /Variance re ui Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker lood Plain Certification, if required .,VOkay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\lnspection Forms\Res, Final Inso. form 2.docLast printed 2/12/04 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/pm D art: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT #: LOCATION: _ '- INSPECT ON: t� S TYPE OF STRUCTURE: - Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min. Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper, CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.lnspectionTORMS\Rough Plumbing Insulation Report.doc November 17,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams ,— Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more --�, Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate C I v 1 %z w) 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses ` Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall �w��Z Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side /2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade I QUEENSBURY z OF—. r -TQ RIN ING & C 4 z Otis p r �c � r REVIONEO BY 0PT i i T _ i �� � 0� C��S�,��'��� ' _�'.:'':�_ti�;. , }���. Y�r�nVct� tip► `D1�7 ''I 4 y zx ... m 14 spy 1 5 j O L„9 � �l J. O "S i 1J�1 a /� t _ _ ___, f � ,� - -- -__w.�� � �, �. _ __� -.�z...., ,�, �..y .- ____ � ` �_. �m�._. _ _ ..�_� � E -` _ c cs f i �, '� � # e`� � e. .a...e..,__"".�._._�.,�L.�..._.......�.__...�,..,I ...r.�.« n...�..._a.._ � t ffi ttt .. t.,.,r:�,...a-mow _. _ � F _......_....._�._ t' .. -/ �. �+,x% ,' j, ,err' �/y� t ;t� �--....__. . __ m f p 1,t _ I _ rl �.... �� � S �, �.._ _ `� .. - „ 7 '-_.._ _�.�.w„�.�.a •L:s� t,v .�.-, { Z� Y„ i _ ��� k. � t �_ r -�' . _ .. - t _#..., � �_ . { i LS , 1 L _ i z ; i i f i l j 4 ! { i i t i - � L s -62ILa Permit Number Checked By/Date Generated by REScheck-Web Software Compliance Certificate Project Title: garage renovation Energy Code: New York State Energy Conservation Construction Code Location: Albany County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Window-to-Wall Ratio: 0.10 Heating Degree Days: 6894 Report Date: Date of Plans:8-2.05 Project Information: Builder information: Alteration to garage Patrick Burke Construction Project Notes: Compliance Passes Maximum UA 168 Vour Home UA:95—43.5% Better Than ..- Ceiling 1:Flat or Scissor Truss 720 30.0 30.0 12 Wall 1:Wood Frame,16in.o.c. 1008 19.0 19.0 30 Door 1:Solid 21 0.330 7 Window 1:Vinyl Frame,2 Pane w/Low-E 15 0.330 5 Window 2:Vinyl Frame,2 Pane w/Low-E 15 0.330 5 Window 3:Vinyl Frame,2 Pane w/Low-E 15 0.330 5 Window 4:Vinyl Frame,2 Pane w/Low-E 10 0.380 4 Window 5:Vinyl Frame,2 Pane w/Low-E 10 0.380 4 Window 6:Vinyl Frame,2 Pane w/Low-E 31 0.350 11 Floorl:All-Wood Joist/Truss Over Uncond.Space 720 30.0 30.0 12 Statement of Compliance:The proposed building represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. Builder/Designer Company Name Date Page 1 Generated by REScheck-Web Software REScheck Inspection Checklist Project Title: garage renovation Ceilings: ❑ Ceiling 1:Flat or Scissor Truss,R-30.0 cavity+R-30.0 continuous insulation Comments: Above-Grade Walls: L] Wail 1:Wood Frame,16in.ox.,R-19.0 cavity+R-19.0 continuous insulation Comments: Windows: ❑ Window 1:Vinyl Frame,2 Pane w/low-E,U-factor:0.330 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: CJ Window 2:Vinyl Frame,2 Pane w/Low-E,U-factor.0.330 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: L] Window 3:Vinyl Frame,2 Pane w/Low-E,U-factor:0.330 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: C3 Window 4:Vinyl Frame,2 Pane w/Low-E,U-factor.0.380 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: L] Window 5:Vinyl Frame,2 Pane w/Low-E,U-factor:0.380 For windows without labeled U-factors,describe features: Vanes Frame Type Thermal Break? Yes No Comments: EJ Window 6:Vinyl Frame,2 Pane w/Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: L3 Door 1:Solid,U-factor:0.330 Comments: Floors: L3 Floor1:Ail-Wood Joist/truss over Uncond.Space,R-30.0 cavity+R-30.0 continuous insulation Comments: Air Leakage: that are sources of air leakage must be sealed. El joints,penetrations,and all other such openings do the building a envelope appropriate air-tight assembly with a 0.5"clearance from L] Recessed lights must be 1)Type IC rated,or 2)installed inside an ppro Page 2 i combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed 1plain\f21fs20 in accordance with the manufacturers installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values and glazing U-factors must be dearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-8. ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-4. 0 Supply ducts in unconditioned spaces must be insulated to R-8. ❑ Return duds in unconditioned spaces(except basements)must be insulated to R- ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2. .Insulation is not required on return ducts in basements. Duct Construction: ❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastks must be rated UL 181 A or UL 181 B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters are required for each dwelling unit. Fireplaces: ❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors. [] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New Yot*State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [] All heated swimming pools must have an onloff heater switch and require a cover unless over 20%of the heating energy is from non-deplelable sources.Pool pumps require a time clock. Heating and Cooling piping insulation: ❑ HVAC piping conveying fluids above 105°F or chilled fluids bsknn 55°F must be insulated to the levels in Table 2. Page 3 Table 1:Minimum insulation Thickness for Circulating Hot Water Pipes Insulation Thickness In Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-160 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes.Hot Water Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range("F) 2"Runouts V and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressurefremperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40 55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Page 4