Loading...
2005-637 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 4z Community Development- Building &Codes (518) 761-8256 CERTIFICATE (.3"'FE' OCCUPANCY Permit Number. P20050637 Date Issued: Monday, August 13, 2007 This is to certify that work requested to be done as shown by Permit Number P20050637 has been completed. Location: 30 SUNSET Ln Tax Map Number. 523400-226-019-0001-005-000-0000 Owner. PAUL SHERMAN JR Applicant: PAUL SHERMAN JR This structure maybe occupied as a: Garage - 2 Cars Attached By Order of Town Board Residential Addition TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050637 Application Number: A20050637 Tax Map No: 523400-226-019-0001-005-000-0000 Permission is hereby granted to: PAUL SHERMAN JR For property located at: 30 SUNSET Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: PAUL SHERMAN JR STEPHANIE SHERMAN Garage Attached 703 MAPLE Ln Residential Addition $43,000.00 NISKAYUNA, NY 12309-0000 Total Value $43,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2005-637 368 sq ft RESIDENTIAL ADDITION, 90 SQ FT WALKWAY AND 500 SQ FT 2-CAR ATTACHED GARAGE $125.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday, September 02, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T,awn o ueen ri ptember 02, 2005 SIGNED BY4 Afor the Town of Queensbury. Director of Building&Code Enforcement Permit No. _ =G 7 Building&Codes Office-Department of Community Development-Town of Queensbury Fee Paid z 742 Bay Road,Queensbury,NY 12804 Recreation Fee Dave Hatin,Director codes@queensbury.net Phone: (518) 761-8256 FAX: (518) 745-4437 Principal Structure Building Permit Application Application & Plans subject to review before issuance of a valid permit for construction Instructions: A permit must be obtained before beginning construction. No inspections will be made until the applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the application form. Ap nt/Builder Avti t-411dwe Owner: 01401 ✓ 5F. Address: &o&& A? Address: 701 00 f w /2 alO Home Phone: 7 30 Home Phone: Email Address: Email Address: Cell Phone: Cell Phone: FAX Phone: FAX Phone: 9 -10.4a0 Person responsible for /supervision ^of work with ressptectt to building and codes compliance: Name: �i0y'� rct6✓ �-•��. CDrNOTC C�6/�lkylr�Address: Q v_arr. IVY- Phone 7H -600 " 3o Location of proposed construction: Lot No. Legal Address: S � �.•rE OW Tax Map Number: ' ` ' Subdivision Name: e4ore (t? �cf 3 �:. Estimated Cost of Construction. $ o06. od - Proposed construction is for: _Residential Use ,Commercial Use AUG Name of Business: If proposed construction is an addition, what will use of new addition be? � Ol[ New Addition Alteration Proposed Construction 10 Floor 2nd floor Other Total Proposed structure (Occupancy Type) Sq.Ft. sq.ft. Sq.Ft. Square feet Height Ft.&in. Single-Family Dwellin • Two-family Dwelling Townhouse Multifamily Dwelling Number of Units: Office Mercantile Manufacturing Other: W #C 1JN �. Attached Gara a 1,113 Op Type of Heating System: Electric, Oil, Gas, tz Forced Ho ir, Baseboard, Other:t0fft 0 Is a fireplace and/or woodstove bein In��st""ailed, IeV refer to a separate application. _Yes No Applications are subject to ZAing Administrator, Code Compliance, and Structural Plan review. The Building and Codes Office will allow commencement of your proposed project only after issuance of your permit. Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all jne onstruction. Date: 7' ©b Applicant/134ider Signature: The application of dated is hereby approved and permission granted for the construction, reconstruction or alteration of a building/and or accessory structure as set forth above. Date: Authorized Signature: L:\Sue Hemingway\Building.Permit.FORMS\Principal Structure Permit Application.doc V:12/14/04 Z / -7 te� gll�)A(l . Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive:'Li-10 am/pm Depart: am/pm Date Inspection request received: Inspector's Initials: � y NAME: PERMIT#: 057-637 . LOCATION: DATE: - TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/'B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopjing finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp, 110 Enclosed Stairs Sheetrock Underside minimum''/2'Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/a hour fire door/door closer Duct work Sealed properly. Gas Logs in Sealed or.ClaA Fnclosure Final Electrical I 1 Final Survey Plot Pla As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O[Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspeetion Forms\Residential Final Inspection Form revised 100405.doc Framing / Firestopping Inspection Report Office No.(518) 761-8256 Date In ectio r uest received: Queensbury Building&Code Enforcement Arrive: am/p Depart:_a m/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: /J PERMIT#: LOCATION: z,r 2 i INSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w) 16 gauge(8) 16D nails each side D ft stopping 1,000 sq. ft. floor trusses i Anchor Bolts 6 ft. or less on center , 1 Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade G-. w V Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Ins ection re Queensbury Building&Code Enforcement Arrive: p part: a pm 742 Bay Road,Queensbury,NY 12804 Inspector's Ini als. r NAME: PERMIT#: 0-5 437 LOCATION: INSPECT ON: TYPE OF STRUCTURE: Framing �' N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft.floor trusses 01 . ss on center Ice and water shield 24 hes from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 'lz inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Foundation Inspection Report Office No. (518)761-8256 Date Inspecti truest received: Queensbury Building&Code Enforcement Arrive: am/pm I epart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspec 's itials: i(� NAME: /t-► PERMIT#: a (P3 LOCATION: INSPECT ON: TYPE OF STRUCTURE-' Comments V N N/A Footings GA-C Piers Monolithic Slab Reinforcement in Place r ' The contractor is responsible-or providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date lnsne 'iquest received: Queensbury Building&Code Enforcement Arrive: hr pi Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspecto 's Initials: NAME: 4 'd PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUC Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour re wall 2, 31 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 7 sf above/below grade 5.0 sf grade Rough Plumbing O Insulation Inspection Repo Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart: am/p 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: ' 6k-k AA) PERMIT #: 0 �5 7 LOCATION:_ 3v 6uc:,g--T 0 i--,j INSPECT ON: a- s- ce TYPE OF STRUCTURE: 1-11 Y N N/A �Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Presser Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes 7Pes, sure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codesldnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 �-- (6 C�Y�--- Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date In cti request received: Queensbury Building&Code Enforcement Arrive: , Oam/ i art: am/pin 742 BayRoad ueensbu NY 12804 Inspector s` Initi 1 `' � Q rY� p a s.� NAME: �{J`v�a PERMIT#: OS 3 LOCATION: ") INSPECT TYPE OF STRUCTURE: Y N N/A COMMENTS J F ttic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z w) 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Foundation Inspection Report / () Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: anv Depart: 4 __ m/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT#: os—G3q LOCATION: L INSPECT ON: :--� TYPE OF STRUCTURE: Comments ------ Y N N/A Fos ---------------- — Piers/ onolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. _ Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: — 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfiil Approval Plumbing Under SIab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 ♦i• 1� fill WARREN COUNTY MICHAEL R. SWAN REAL PROPERTY T,QX SERVICES AGENCY Director _ ♦� County Municipal Center 1340 State Route 9 aiiti_*o+~ Lake George,New York 12845 TERI ROSS Tel. 518-761-6464 Deputy Director Fax 518-761-6559 WARREN COUNTY TAX MAP OFFICE REQUEST FORM FOR THE CONSOLIDATION OF TAX MAP PARCELS TOWN/CITY OF ' TAX MAP NUMBER OF EACH PARCEL TO BE CONSOLIDATED4 Cl # z AssC:ssoR's O 'S SIG ATURE OWNER'S SIGNATURE l DATE DATE 1 **ALL TAXES MUST BE CURRENT ON ALL PARCELS TO] / WARREN COUNTY TREASURER'S OFFICE VERIFY Are there any outstanding taxes on the above ref f� YES NO TOWN ASSESSOR'S APPROVAL: YES NO VEre��s Any parcels that are to be consolidated MUST SHOW IDENTICAL owner deed information on each parcel. Please be advised that any additional congolidation/split requests concerning the above parcels may result in a$15.00 processing fee being charged to the property owner. �- C' - a '�//,;,/ / TOWN OF UEENSBURY� 742 Bay d, Queeusbu NY. 12804-5902 August 27 g 2005 Au Mr. Paul Sherman, r. �J; _���� 1'f ✓� 703 Maple Lane S� Niskayuna, NY 12309i Re: 30 Sunset Lane; cel 226.19-1-5 Ls 6-4 and -6] Dear Mr. Sherman: We are in receipt of your building permit application to improve a residence. We need proof of consolidation of parcels to make building setback determinations. In addition, you wkneed to comply with §179-5-040 to convert a seasonal dwelling to a year-round residence.,(your_property is currently assessed as a seasonal residence]. Please contacd Dave I atin,-birector of Buildings & Codes at 761-8253 for details. As per §179-5-1 10 you will also need to contact Mr. Hatin to comply with sanitary sewage requirements due to an increase in floor area in a waterfront district. ,'�,�as� �=-- C on of batlding..hei ht is needed. A maximum height of 16 ft. is allowed Me ft.?' � PL AT NO BUILDING PERMITS CAN BE ISSUED UNTIL SUCH TIME AS z' ZONING REQUIREMENTS HAVE BEEN MET. Please contact Susan Barden, our Land Use Planner, at 761-8265 to set up an �: �(t 't appointment to go over the requirements. Our deadline date for applications is the 15th of each month. We respectfully request that you contact us at least one week C-) before applications are due to allow adequate time for any changes that may n6ed to if be made upon discussion. Thank you. Sincerely, ? Town of Queensbury ti Marilyn Ryba, Acting Zoning Administrator ` s ' Community Development L:\Zoning Determinations\Draft Sherman 226.19-1-5,4,6 on 8-27-05.doc Cc: Susan Barden, Land Use Planner; Dave Hatin, Director of Buildings & Codes; Craig Brown (all via e-mail) "Horne of Natural Beauty ... A Good Place to Live " P.E.Sherman, Jr., Esq. Attorney and Counsellor at Law -�+ 703 Napie Lane-Nislzayuna.NY 12309•(518)377-7446 (� l ow✓N c % ��eeKY� nn ( -I-Zkl,-� a-s zoos : 3 o S y s c,4 l-A..&,e S f e'C G K�' •h Pe.r wl i'+ (GO✓ r0 1� 0wI%A I' ��✓0�w�e `�s � d �� Vim , d� L� 1 GL`I d O v" C Ovave�Q Po f,� a 1 4-, .5- S u n✓� fw{ 500 JcLv n y-e. '" v ' s�k,✓C 1 P�✓cc�S e . O U, VN � [ C—V'ON tbe- Se� 6 k r�y�'►� ew s ow,, C��t✓��� � � 1`S Oct_U I' Pu- le-v- 7 13 - 13� &, ji (Zov oc,,,e -7 �ec4 r"M 11 Ll SI,,eV-vnof—n Site Nbad Site Nbad Nbad Road Entry Zoning Sewer Water Utilities # Code Desire Type Rating Tyne Type Code 102- 1 Lake 2 3 3 2 2 2 3 1 WR-1 A Area Land Information: Site# Land# Type Front Depth Acres Sq Ft 1 1 01-Primary 75 135 0 0 Building 14formation. Site Bldg # wall Yr # # # 1/2 # # Heat Fuel Central Bsmt Overall Constr # Style Stories Mat Built Kit.Baths Baths Be km Firepll TvDe Tvne Air Tyke Cond Grade 1 11 1 01 1957 1 1 3 1 4 3 0 1 3 C Im rp ovements Information: / Site Struct Code Dim Dim SQ Constr Overall Yr J / _ /C / # � �l # 1 2 FT —Grade Cond Built /V a I RPI-Porch- 14 6 0 1 C 3 1985 open/deck Special Districts Information: Special District Units Percent EM001-Emergency 0 0 medical FP007-Fire protection 0 0 LB001-Crandall library 0 0 dst SE001-Sewer cnty dist no 0 0 1 WT015-Shore colony 0 0 water RPS Building Permit Information: Permit Number Permit Date Permit Use Cost Estimate P19550083 Addition 0 http://gls.queensbury.net/gis/RPS—INF02.ASP?printkey=226.19-1-5 5/2/2005