Signed Inspection Report (10-27-2020) (16).pdfINSPECTION WORKSHEET (POOL-005849-2020)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:POOL-0175-2020 Case Module:Permit
Inspection Date:Tue Oct 27, 2020 Inspection Status:Failed
Inspector:Dyer, Charles Inspection Type:Pool
Job Address:Parcel Number:39 NORTHWOOD DR
Lake George, NY, 12845
288.16-1-5.1
Contact Type Company Name Name
Applicant Haverly, Colleen
Primary Owner Haverly, Colleen
Granted Permission Haverly, Colleen
Contractor Concord Pools and Spas
Checklist Item Status
Building Inspector Notes Failed
10/27/20 observed pool is covered for winter season, permanent fence installed. Pool must be inspected by TOQ
code enforcement prior to use. Please call 518-761-8207 to verify you have received this notice and possibly set
time and date prior to 2021 use of pool.
ÿþ Failed
Pool enclosure around pool or yard Failed
4 feet above grade Failed
2 inch max to grade from underside of fence Failed
Oct 27, 2020 Page (1)
INSPECTION WORKSHEET (POOL-005849-2020)
Checklist Item Status
4 inch maximum clearance in fence pickets Failed
Maximum spacing of wire fence 1 3/4"Failed
Self closing device or alarms (30 sec Alarm time)Failed
Pool Surface Motion Alarm Failed
Ladder secured in place and latched Failed
Gate less than 56 to latch ½ max spac in openings Failed
Gate opens outward, self closing Failed
Padlock provided on gates or ladder Failed
Indoor pools all doors self closing or alarmed Failed
Timer on pool pump (no plug in timer allowed)Failed
Suction outlt must be protected agst user entrpmnt - (eff 5/12/2020)Failed
Bottom pool drain vacuum relief system-REQUIRED Failed
Oct 27, 2020 Page (2)
INSPECTION WORKSHEET (POOL-005849-2020)
Checklist Item Status
Final Electrical Failed
Vehicle access gate closed & locked Failed
Ok to issue CC Failed
Oct 27, 2020 Page (3)
Dyer, Charles