74 Rt. 149 QEI Elev. Inspection Report
Company: Capital District Elevator LLC
Address: 681 Maple Lane
City, State,Zip: Niskayuna, NY 12309
Inspector: Harry Horton E-1245 _
Initial Insp. Date: 10/26/2020 11/06/2020
A17.1 - 2016. - 5.3
ROUTINE INSPECTION REPORT FOR ELEVATORS, ESCALATORS
Building: Lake George RV Park King Residence Contractor: Northern Lifts
Address: 74 RT 149 Queensbury, NY 12804
Authority: BCNY, T of Q. Inspections Due: Acceptance
Car Common ID 1 Car Rnby Top 4”
Car Unique ID CX936221 No Load PSi 380
Car AHJ ID TBD Full Load PSi 650
Rise 3 Relief PSI 880
Pass/Freight Pass Limit Switches Pass
Capacity/FPM 950-40 Battery Lowering Pass
Type Roped Hydro Up Speed NL 43
Make / Model Northern Lifts Luxe-
Hydro Down Speed NL 45
Age 2020 Safety Test FL. Pass
Code Year 2016 Full Load Up Spd 32
Emerg Phone Pass Full Load Dwn Spd 52
Emerg Lights Pass LOT/Stall Time Pass
Door Torque Pass Pressure Switch Pass
Fire Service I, II None Mach Room Pass
Car Rnby Bot 6” Pit Pass
O/S Rupture Valve Pass Car Top Pass
NOTICE: This report has been complied through the process of interview and observation. The report reflects only those conditions and
practices which could be ascertained through interview and observation at the time of the call by the inspector. It does not represent that
hazards and/or exposures not shown hereon do not in fact exist. We do not assume any responsibility for inaccurate or erroneous information,
express or implied, given to the Inspector or to any other matters beyond our cause and control.