BISV-003355-2020 07082020INSPECTION WORKSHEET (BISV-003355-2020)
AST-0094-2020Permit Management
Case Number:Case Module:
07/08/2020Failed
Inspection Date:Inspection Status:
Charles DyerBuilding Inspector Visit
Inspector:Inspection Type:
240.6-1-5
Job Address:Parcel Number:
2469 Ridge Rd
Queensbury, NY 12804
Contact TypeCompany NameName
ApplicantRobert Kendall Jr.
Granted PermissionRobert Kendall Jr.
Primary OwnerRobert Kendall Jr.
Checklist ItemPassedComments
Building Inspector NotesFalse
Site check for deck partially built for advice on construction of deck
for use of type of hardware I.e. joist hangers, tension ties, bolts:
advised to use rated hardware for pressure treated lumber, to
refrain from carriage bolts and to be of galvanized, remove current
joist hangers and replace with size to match 2x12s, provide lateral
bracing off uprites to ledger beam. Permit has not been issued.
December 11, 2020Page 1 of 1