BINS-001217-2019 03012019INSPECTION WORKSHEET (BINS-001217-2019) CC-0005-2019Permit Management Case Number:Case Module: 03/01/2019Partial Pass Inspection Date:Inspection Status: John O'BrienCommercial Final Inspection Inspector:Inspection Type: 308.20-1-3.3 Job Address:Parcel Number: 75 Carey Rd Queensbury, NY 12804 Contact TypeCompany NameName ApplicantJ. Luke Construction ArchitectMonarch Design Group LLC ContractorJ. Luke Construction Granted PermissionOkie Properties, LLC Primary OwnerOkie Properties, LLC TenantMotimac USA Checklist ItemPassedComments Low flow toilet 1.3 gal/flushing cycleTrue Firewalls, 2 Hr, 3 Hr / Fire Dampers / Fire DoorsFalse Bldg Num or Tenant Address on Bld or DriveTrueInstall Suite Number Gas Shut-off Exposed & Regulator (18) Above GradeTrue Handicapped Service Counters 34 inchFalse -Install break room counter with sink as per plan, range not allowed. Remove outlet box from break room partition, wiring and breakers from panel for range. Gas Furnace Shut OffTrue Engineer or Architect ApprovalTrue Chimney Rain Cap InstalledTrue OK to Issue C/OFalse 2/28/19 Final Inspection Not Approved Remaining Items: -Submit HVAC Air Balancing Report for Suite #1 & #2 -Install Suite Number -Install right handed flush handle handicapped toilet. -Install break room counter with sink as per plan no stove. -Complete Fire Marshal's Items. Chimney / B Vent / Direct Vent LocationTrue Universal Symbol of Access displayedTrue Final Electrical / Flex Gas Piping BondedTrue Plumbing Vent Through Roof/Roof completeTrue Relief Valve ,Heat Trap/Water Temp 110 deg or lessTrue Handicapped Bath/Parking Lot SignageTrue Exits At Grade Or Platform 36 (w) x 44 (l)True H/C toilet flush handle on open sideTrue December 15, 2020Page 1 of 2 INSPECTION WORKSHEET (BINS-001217-2019) Checklist ItemPassedComments OK to Issue Temporary C/OFalse 3/1/19 Final Inspection Partial Approval-Ok to Issue a Temporary CO! Conditions -Submit HVAC Air Balancing Report for Suite #2 -Install break room counter with sink as per plan, range not allowed. Remove outlet box from break room partition, wiring and breakers from panel for range. -Complete outstanding Fire Marshal’s item regarding wiring of emergency lights and exit signs for each individual tenant space. Occupancy sensor lighting controlTrue Special InspectionsFalse-Submit HVAC Air Balancing Report for Suite #2 Doors 36 inch wLever Hand Panic Hardware, if reqTrue Floor Bathroom Watertight Other Floors OkayTrue December 15, 2020Page 2 of 2