Signed Inspection Report (12-18-2020) (8).pdfINSPECTION WORKSHEET (RESFINAL-007237-2020)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0686-2018 Case Module:Permit
Inspection Date:Fri Dec 18, 2020 Inspection Status:Partial Pass
Inspector:Dyer, Charles Inspection Type:Residential Final Inspection
Job Address:Parcel Number:9 PARK VIEW AVE
Queensbury, NY, 12804
302.14-3-47
Contact Type Company Name Name
Primary Owner Gammon Construction LLC
Applicant Gammon Construction LLC
Granted Permission Gammon Construction LLC
Contractor Gammon Construction LLC
Checklist Item Status
General Comments Failed
Provide handrails as discussed
Provide attic access (fire rated door) garage
Mineral wool at drain basement
Call for recheck
CO in Bedrooms w/Gas Failed
Chimney Rain Cap Installed Failed
Handrail 4 or more risers Failed
Provide handrail garage stairs and basement stairs
Handrail Termination at Newell Post or Wall Failed
Dec 18, 2020 Page (1)
INSPECTION WORKSHEET (RESFINAL-007237-2020)
Checklist Item Status
Interior/Exterior Railings 34 to 38 Failed
Wood deck: 2'+ from grade dia bracing required - H/C ramp compliant Failed
4+ Deck Joist Ledger Connections-24" From Ends Failed
Deck Ledger-Bolted per Code Failed
Grade away from foundation: 6" down, 10' out Passed
Verified prior to snow fall 12/16/20
HVAC Vent Terminal 10' from Lot Line & Openings Failed
CO in Bedrooms w/Gas Failed
Attic Access 22 x 30 minimum Failed
Provide attic access as discussed
Attic Access Insulation = Attic R- Value Failed
Attic Access Gasketed Failed
Plumbing fixtures Failed
Provide mineral wool @ drain in basement
Dec 18, 2020 Page (2)
INSPECTION WORKSHEET (RESFINAL-007237-2020)
Checklist Item Status
Range Hood 400+ cfm-Fresh Air REQUIRED Passed
No range hood
20 Minute Fire Door/Self-Closing Hardware Failed
Final Survey Plot Plan Passed
Received
OK to Issue Temporary C/O Failed
OK to Issue C/O Failed
Dec 18, 2020 Page (3)
Dyer, Charles