Loading...
Signed Inspection Report (Fri Dec 18, 2020 at 302 PM)INSPECTION WORKSHEET (FDTN-007229-2020) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0621-2020 Case Module:Permit Inspection Date:Fri Dec 18, 2020 Inspection Status:Partial Pass Inspector:O'Brien, John Inspection Type:Building Foundation Job Address:Parcel Number:719 BAY RD Queensbury, NY, 12804 289.19-1-27 Contact Type Company Name Name Contractor BBL Construction Services Applicant BBL Construction Services Granted Permission BBL Construction Services Primary Owner Rosetti Acquisitions LLC Architect HCP Architects, LLP Checklist Item Status Dec 18, 2020 Page (1) INSPECTION WORKSHEET (FDTN-007229-2020) Checklist Item Status Building Inspector Notes Failed 10/26/20 recieved compaction tests 11/24/20 Footing Partial Approval T-17 to C-11 12/2/20 Footings Partial Approval - West Elevation from C-11 to stair tower 1 to North of elevator at G16. 12/9/20 Foundation Partial Approval - Foundation Walls partial approval from F12.5 to T4.5, Elevator #1 and Stair #1. - Footings Partial Approval from T16 to T29 12/11/20 Foundation Partial Approval - Foundation Insulation installed from H3 to D9 - Backfill Partial Approval from H3 to D9 12/16/20 Foundation Partial Approval - Foundation Walls T5 - T19 - Footings T25 - B38 12/16/20 Foundation Partial Approval - Foundation Insulation D9 - T18 - Backfill D9 - T18 12/18/20 Foundation Partial Approval - Footings G16 - F24 Footings Passed 11/24/20 Footing Partial Approval T-17 to C-11 12/2/20 Footings Partial Approval 12/2/20 Footings Partial Approval - West Elevation from C-11 to stair tower 1 to North of elevator at G16. 12/9/20 Foundation Partial Approval - Footings Partial Approval from T16 to T29 12/16/20 Foundation Partial Approval - Foundation Walls T5 - T19 - Footings T25 - B38 12/18/20 Foundation Partial Approval - Footings G16 - F24 Dec 18, 2020 Page (2) INSPECTION WORKSHEET (FDTN-007229-2020) Checklist Item Status Piers Failed Monolithic Slab Failed Reinforcement in Place Passed 11/24/20 Footing Partial Approval T-17 to C-11 12/2/20 Footings Partial Approval - West Elevation from C-11 to stair tower 1 to North of elevator at G16. 12/9/20 Foundation Partial Approval - Footings Partial Approval fromT16 to T29 12/16/20 Foundation Partial Approval - Foundation Walls T5 - T19 - Footings T25 - B38 12/18/20 Foundation Partial Approval - Footings G16 - F24 Foundation / Wallpour Passed 12/9/20 Foundation Partial Approval - Foundation Walls partial approval from F12.5 to T4.5, Elevator #1 and Stair #1. 12/16/20 Foundation Partial Approval - Foundation Walls T5 - T19 - Footings T25 - B38 Reinforcement in Place Passed 12/9/20 Foundation Partial Approval - Foundation Walls partial approval from F12.5 to T4.5, Elevator #1 and Stair #1. 12/16/20 Foundation Partial Approval - Foundation Walls T5 - T19 - Footings T25 - B38 Dec 18, 2020 Page (3) INSPECTION WORKSHEET (FDTN-007229-2020) Checklist Item Status Masonry Wall Failed Reinforcement in Place Failed Footing Dowels or Keyway in place Passed 11/24/20 Footing Partial Approval T-17 to C-11 12/2/20 Footings Partial Approval - West Elevation from C-11 to stair tower 1 to North of elevator at G16. 12/9/20 - Footings Partial Approval fromT16 to T29 12/16/20 Foundation Partial Approval - Foundation Walls T5 - T19 - Footings T25 - B38 12/18/20 Foundation Partial Approval - Footings G16 - F24 Foundation Dampproofing Failed Foundation Waterproofing Failed Footing Drain Daylight or Sump Failed Footing Drain Stone - 12 inch width Failed Footing Drain Stone - 6 inches above footing Failed Footing Drain stone - 6 mil poly Failed Dec 18, 2020 Page (4) INSPECTION WORKSHEET (FDTN-007229-2020) Checklist Item Status Backfill Approval Passed 12/11/20 Foundation Partial Approval - Foundation Insulation installed from H3 to D9 - Backfill Partial Approval from H3 to D9 12/16/20 Foundation Partial Approval - Foundation Insulation D9 - T18 - Backfill D9 - T18 Plumbing Under Slab Failed PVC / Cast / Copper Failed Foundation Insulation Interior / Exterior Passed 12/11/20 Foundation Partial Approval - Foundation Insulation installed from H3 to D9 - Backfill Partial Approval from H3 to D9 12/16/20 Foundation Partial Approval - Foundation Insulation D9 - T18 - Backfill D9 - T18 Rough Grade 6 inch drop within 10 ft.Failed Poly Under Slab Failed Dec 18, 2020 Page (5) O'Brien, John