ResCheck REScheck Software Version 4.' Igli 6.3
Compliance Certificate
EVECEllyE ,
Project New Model Home
, ti.))
Energy Code: 2015 IECC 1 1111 OCT 3 1 Z018
Location: Glen Park, New York
Construction Type: Single-family TOWN OF QUEENSBURY I
Project Type: New Construction IG&CODES
Conditioned Floor Area: 1,495 ft2 302.14-3-47 RC-0686-2018
Glazing Area 12% Gammon Construction LLC
Climate Zone: 6 (7753 HDD)
Permit Date: 9 Park View Ave
Permit Number: SFD w/gas FP 1492 s.f., Gar. 498 s.f.
Construction Site: Owner/Agent: Designer/Contras:
Park View Drive Gammon Construction Ethan Peter Hall
Queensbury, NY 12804 30 Clement Ave Rucinski Hall Architecture
Saratoga Springs, NY 12866 134 Dix Ave
Glens Falls, NY 12801
518-741-0268
ephall@nycap.rr.com
Compliance: Passes using UA trade-off
Compliance: 0.0%Better Than Code Maximum UA: 236 Your UA: 236
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Ceiling 1: Raised or Energy Truss 1,495 51.0 0.0 0.019 28
Wall 1: Wood Frame, 16"o.c. 298 21.0 0.0 0.057 15
Door 1: Solid 20 0.300 6
Door 2: Solid 18 0.300 5
Wall 2: Wood Frame, 16"o.c. 500 21.0 0.0 0.057 25
Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 60 0.290 17
Wall 3: Wood Frame, 16"o.c. 298 21.0 0.0 0.057 14
Window 2:Vinyl/Fiberglass Frame:Double Pane with Low-E 39 0.290 11
Door 3: Glass 18 0.340 6
Wall 4: Wood Frame, 16"o.c. 500 21.0 0.0 0.057 26
Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 46 0.290 13
Basement Wall 1: Solid Concrete or Masonry 236 0.0 15.0 0.051 12
Wall height: 7.9'
Depth below grade: 6.0'
Insulation depth: 7.5'
Project Title: New Model Home Report date: 10/30/18
Data filename: Y:\Gammon\Park View\New Lot- March 2017\Park View 2018 - rev 1.rck Page 1 of10
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Basement Wall 2: Solid Concrete or Masonry 395 0.0 15.0 0.051 19
Wall height: 7.9'
Depth below grade: 6.0'
Insulation depth: 7.5'
Window 4: Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.290 5
Basement Wall 3: Solid Concrete or Masonry 236 0.0 15.0 0.051 12
Wall height: 7.9'
Depth below grade: 6.0'
Insulation depth: 7.5'
Basement Wall 4: Solid Concrete or Masonry 395 0.0 15.0 0.051 20
Wall height: 7.9'
Depth below grade: 6.0'
Insulation depth: 7.5'
Window 5:Vinyl/Fiberglass Frame:Double Pane with Low-E 8 0.290 2
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.3 and to comply with the mandatory requirements ' d in th ES k Ins ection Checklist.
Ethan Peter Hall-Architect • 50 Oar (e1gl
Name-Title Signat Date
r
Project Title: New Model Home Report date: 10/30/18
Data filename: Y:\Gammon\Park View\New Lot- March 2017\Park View 2018 - rev 1.rck Page 2 of10
rREScheck Software Version 4.6.3
‘ h Inspection Checklist
Energy Code: 2015 IECC
Requirements: 100.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section --
# Pre-Inspection/Plan Review Plans Verified Field Verified Complies? Comments/Assumptions
& Req.ID Value Value
103.1, Construction drawings and EComplies Requirement will be met.
103.2 documentation demonstrate ElDoes Not
[PR1]1 energy code compliance for the Location on plans/spec:A-
V building envelope.Thermal ['Not Observable 1
envelope represented on ElNot Applicable
construction documents.
103.1, Construction drawings and ['Complies Requirement will be met.
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for Location on plans/spec:A-
[PR3]i lighting and mechanical systems. ❑Not Observable 1
t, Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies Requirement will be met.
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling: Location on plans/spec:A-
d, Manual J or other methods Btu/hr Btu/hr ❑Not Observable 1
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 I Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: New Model Home Report date: 10/30/18
Data filename: Y:\Gammon\Park View\New Lot- March 2017\Park View 2018 - rev 1.rck Page 3 of10
Section
# Foundation Inspection Plans Verified Field Verified
p Value Value Complies? Comments/Assumptions
& Req.ID 1
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
[F04]1 insulation R-value.Where interior R- R- ❑Does Not table for values.
insulation is used,verification
may need to occur during ❑Not Observable
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies Requirement will be met.
[F05]1 insulation installed per ❑Does Not
manufacturer's instructions. Location on plans/spec:A-
['Not Observable 1
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ElComplies See the Envelope Assemblies
[F06]1 insulation depth of burial or ❑Does Not table for values.
distance from top of wall.
DNot Observable
ElNot Applicable
303.2.1 A protective covering is installed ❑Complies Exception: Requirement is
[F011]2 to protect exposed exterior ❑Does Not not applicable.
insulation and extends a ['Not Observable
minimum of 6 in. below grade.
ENot Applicable
403.9 Snow-and ice-melting system ❑Complies Exception: Requirement is
[F012]z controls installed. ❑Does Not not applicable.
['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) , 3 [Low Impact(Tier 3)
Project Title: New Model Home Report date: 10/30/18
Data filename: Y:\Gammon\Park View\New Lot- March 2017\Park View 2018 - rev 1.rck Page 4 of10
Section
# Framing/Rough-In Inspection Plans Verified Field Verified Complies? Comments/Assumptions
& Req.ID Value Value
402.1.1, Door U-factor. U U- DComplies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1
DNot Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U DComplies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.3.6, DNot Observable
402.5 DNot Applicable
[FR2]1
303.1.3 U-factors of fenestration products DComplies Requirement will be met.
[FR4]1 are determined in accordance ❑Does Not
v with the NFRC test procedure or Location on plans/spec:A-
taken from the default table. Not Observable 1
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier DComplies Requirement will be met.
[FR23]1 installed per manufacturer's ❑Does Not
instructions. Location on plans/spec:A-
❑Not Observable 1
❑Not Applicable
402.4.3 Fenestration that is not site built DComplies Requirement will be met.
[FR20]1 is listed and labeled as meeting ❑Does Not
t, AAMA/WDMA/CSA 101/I.S.2/A440 ['Not Observable
or has infiltration rates per NFRC
400 that do not exceed code DNot Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures DComplies Exception: Requirement is
[FR16]2 sealed at housing/interior finish ❑Does Not not applicable.
and labeled to indicate <_2.0 cfm [Not Observable
leakage at 75 Pa.
DNot Applicable
403.2.1 Supply and return ducts in attics DComplies Exception: Ducts located
[FR12]1 insulated >= R-8 where duct is ElDoes Not completely inside the
>= 3 inches in diameter and >_ ❑Not Observable building envelope.
R-6 where < 3 inches.Supply and
return ducts in other portions of DNot Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.3.5 Building cavities are not used as ❑Complies Requirement will be met.
[FR15]3 ducts or plenums. ❑Does Not
d Location on plans/spec:A-
❑Not Observable 1
❑Not Applicable
403.4 HVAC piping conveying fluids R-
_ R-
_ DComplies Exception: Requirement is
[FR17]2 above 105°F or chilled fluids ❑Does Not not applicable.
v, below 55°F are insulated to>_R-
g, ['Not Observable
DNot Applicable
403.4.1 Protection of insulation on HVAC DComplies Exception: Requirement is
[FR24]1 piping. ❑Does Not not applicable.
.s
DNot Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- DComplies Requirement will be met.
[FR18]2 ?_.R-3. ❑Does Not
`' ❑Not Observable Location on plans/spec:A-
1
❑Not Applicable
403.6 Automatic or gravity dampers are DComplies Requirement will be met.
[FR19]2 installed on all outdoor air DDoes Not
intakes and exhausts. ❑Not Observable Location on plans/spec:A-
1
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) [ 3 1 Low Impact(Tier 3)
Project Title: New Model Home Report date: 10/30/18
Data filename: Y:\Gammon\Park View\New Lot- March 2017\Park View 2018 - rev 1.rck Page 5 of10
Section
# Insulation Inspection Plans Verified Field Verified Complies? Comments/Assumptions
& Req.ID Value Value
303.1 All installed insulation is labeled ❑Complies Requirement will be met.
[IN13)2 or the installed R-values ❑Does Not
provided.
❑Not Observable
❑Not Applicable
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least lh of the ❑ Wood 0 Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall
[IN3]1 exterior,the exterior insulation ❑ Mass ❑ Mass ❑Not Observable
,, requirement applies(FR10). 0 Steel El Steel ENot Applicable
303.2 Wall insulation is installed per ❑Complies Requirement will be met.
[IN4]1 manufacturer's instructions. DDoes Not
❑Not Observable Location on plans/spec:A-
❑Not Applicable 1
Additional Comments/Assumptions:
I 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) i 3 Low Impact(Tier 3)
Project Title: New Model Home Report date: 10/30/18
Data filename: Y:\Gammon\Park View\New Lot- March 2017\Park View 2018 - rev 1.rck Page 7 of10
Section
# Final Inspection Provisions Plans Verified Field Verified Complies? Comments/Assumptions
& Req.ID Value Value
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2,
402.2.E ❑ Steel ❑ Steel [Not Observable
[FI1]1 ❑Not Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies Requirement will be met.
303.2 manufacturer's instructions. ❑Does Not
[FI2]1 Blown insulation marked every Location on plans/spec:A-
300 ft2. ❑Not Observable 1
❑Not Applicable
402.2.3 Vented attics with air permeable ❑Complies Requirement will be met.
[F122]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that ❑Not Observable Location on plans/spec:A-
extends over insulation. 1
❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies Requirement will be met.
[F13]1 insulation .R-value of the ❑Does Not
adjacent assembly. ❑Not Observable Location on plans/spec:A-
1
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies Requirement will be met.
[FI17]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8. Location on plans/spec:A-
❑Not Observable 1
❑Not Applicable
403.2.3 Duct tightness test result of< 4 cfm/100 cfm/100 EComplies Exception:All ducts and air
[FI4]1 cfm/100 ft2 across the system or ft2 ft2 ElDoes Not handlers are located within
<=3 cfm/100 ft2 without air conditioned space.
handler @ 25 Pa. For rough-in ❑Not Observable
tests,verification may need to ❑Not Applicable
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Exception:All ducts and air
[FI27]1 determine air leakage with ft2 ft2 ❑Does Not handlers are located within
either: Rough-in test:Total conditioned space.
leakage measured with a ❑Not Observable
pressure differential of 0.1 inch ❑Not Applicable
w.g.across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated ❑Complies Requirement will be met.
[FI24]1 by manufacturer at<=2%of ❑Does Not
design air flow. Location on plans/spec:A-
❑Not Observable 1
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies Requirement will be met.
[FI9]2 installed for control of primary ❑Does Not
heating and cooling systems and ❑Not Observable Location on plans/spec:A-
initially set by manufacturer to 1
code specifications. ❑Not Applicable
403.1.2 Heat pump thermostat installed ❑Complies Exception: Requirement is
[FI10]2 on heat pumps. ❑Does Not not applicable.
['Not Observable
❑Not Applicable
403.5.1 Circulating service hot water ❑Complies Exception: Requirement is
[FI11]2 systems have automatic or ❑Does Not not applicable.
accessible manual controls. ❑Not Observable
❑Not Applicable
1 ;High Impact(Tier 1) 1 2 Medium Impact(Tier 2) 13 I Low Impact(Tier 3)
Project Title: New Model Home Report date: 10/30/18
Data filename: Y:\Gammon\Park View\New Lot- March 2017\Park View 2018 - rev 1.rck Page 8 of10
Section
• Final Inspection Provisions Plans Verified Field Verified Complies? Comments/Assumptions
& Req.ID Value Value
403.6.1 All mechanical ventilation system ❑Complies Requirement will be met.
[F125]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy Location on plans/spec:A-
and air flow limits. ❑Not Observable 1
❑Not Applicable
403.2 Hot water boilers supplying heat ❑Complies Exception: Requirement is
[FI26]2 through one-or two-pipe heating ❑Does Not not applicable.
systems have outdoor setback
control to lower boiler water ❑Not Observable
temperature based on outdoor ❑Not Applicable
temperature.
403.5.1.1 Heated water circulation systems ❑Complies Exception: Requirement is
[FI2812 have a circulation pump.The ❑Does Not not applicable.
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe. Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies Exception: Requirement is
[Fl29]2 comply with IEEE 515.1 or UL ❑Does Not not applicable.
515.Controls automatically ❑Not Observable
adjust the energy input to the
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies Exception: Requirement is
[FI30]2 have recirculation pumps that ❑Does Not not applicable.
pump water from a heated water [Not Observable
supply pipe back to the heated
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 1044F.
403.5.4 Drain water heat recovery units EComplies Requirement will be met.
[FI31]z tested in accordance with CSA ❑Does Not
B55.1. Potable water-side ❑Not Observable Location on plans/spec:A-
pressure loss of drain water heat 1
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units< 2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies Requirement will be met.
j[FI6]1 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps. Location on plans/spec:A-
iDoes not apply to low-voltage ['Not Observable 1
lighting. ❑Not Applicable
'404.1.1 Fuel gas lighting systems have ElComplies Requirement will be met.
[FI23]3 no continuous pilot light. Does Not
[Not Observable Location on plans/spec:A-
1
❑Not Applicable
11 High Impact(Tier 1) 2 1Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: New Model Home Report date: 10/30/18
Data filename: Y:\Gammon\Park View\New Lot- March 2017\Park View 2018 - rev 1.rck Page 9 of10
Section Plans Verified Field Verified
# Final inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
401.3 Compliance certificate posted. ❑Complies Requirement will be met.
[FI7]2 ❑Does Not
[Not Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies Requirement will be met.
[F118]3 mechanical and water heating ❑Does Not
systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 1 2 1Medium Impact(Tier 2) 13 I Low Impact(Tier 3)
Project Title: New Model Home Report date: 10/30/18
Data filename: Y:\Gammon\Park View\New Lot- March 2017\Park View 2018 - rev 1.rck Page 10 of10
2015 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
Above-Grade Wall 21.00
Below-Grade Wall 15.00
Floor 0.00
Ceiling / Roof 51.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.29
Door 0.30
Heating&Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments