New Respite Care Facility concrete test report 34 William Street, Ballston Lake, New York 12019 Phone: (518) 399-1848 Email: constructiontech@live.com CLIENT: REPORT NUMBER: : PAGE #: 1 INSPECTION DATE: OUR FILE NUMBER:5 INSPECTOR & TEST SET: DAVE CASAW #5 ATT'N: AMBIENT WEATHER: OUR FILE LOCATION: 1 : PLACEMENT LOCATION OF LOAD # 2 : PLACEMENT LOCATION OF LOAD # 3 : 1 2 0 3 4905 / 840053 4904 / 840056 4903 / 840057 11.00 / 11.00 1 11.00 / 22.00 2 11.00 / 33.00 2.1 12.27 / 1.02 0 ##12.44 / 1.15 0 1.10 / 1.44 0 1.14 / 1.29 # 13 1.29 / 1.44 ##1.45 / 2.06 2.00 MAX: 1.50 )12 1.03 0 12 1.00 0 1 0.93 0 0.27 3.75 1 0.44 4.50 1 0.10 5.00 2 WATER ADDED ONSITE (GALLONS):0.00 0 0.00 0 0.00 0 WATER ADDED AT DISCRETION OF:0.00 # 0.00 ##0.00 0.06 3.75 4.50 5.00 PLACEMENT SLUMP (INCH) (SPEC: - 5.00 ) 3.75 0 4.50 0 5.00 0 ENTRAINED AIR ( % VOL) (SPEC: - 7.00 ) 4.60 0 0.00 0 0.000394800 UNIT WEIGHT (PCF) (SPEC:-0.00 ) 149.54 0 0.00 0 0.00 0 90 ) 84 0 85 0 84 0 NUMBER OF TEST SPECIMEN CAST:6 0 0 0 0 200858 - 200863 0 0 0 0 0 0 0 CONCRETE SUPPLIER:CONCRETE TEST CYLINDER COMPRESSIVE RESULTS PER: ASTM: C39 P.S.I. @ 28 DAYS :UNLESS OTHERWISE NOTED ALL CYLINDERS RECEIVED: CEMENT:LBS.CYLINDER TEST UNIT CEMENT:LBS. NUMBER DATE P.S.I. GAL. COARSE AGGREGATE #1: LBS.200858 07/13/20 7 3240 0 COARSE AGGREGATE #2: LBS.200859 07/13/20 7 3380 0 COARSE AGGREGATE #3: LBS.200860 08/03/20 28 4650 0 FINE AGGREGATE: LBS.200861 08/03/20 28 4720 0 ADMIXTURE #1: OZS.200862 08/03/20 28 4530 0 ADMIXTURE #2: OZS.200863 01/00/00 SPARE 0 X ADMIXTURE #3: OZS. AIR ENTRAINING AGENT: OZS.0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X REPORT DISTRIBUTION:0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 01/00/00 0 0 X RESPECTFULLY SUBMITTED,0 0 0 0 01/00/00 0 0 X CONSTRUCTION TECHNOLOGY 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X ROBERT BEHAN, (NICET)0 0 0 0 01/00/00 0 0 X MANAGER TECHNICAL SVCS.0 0 0 0 01/00/00 0 0 X PROPER HOT OR COLD WEATHER CURING PROTECTION FOR AMBIENT CONDITIONS IS AVAILABLE ONSITE. PER DRAWING: S-202, DETAIL: 5 GENERAL CONSTRUCTION PRACTICE: CONCRETE PROPERLY CONSOLIDATED. NO VISUAL EVIDENCE OF SEGREGATION OR COLD JOINTS. PLACEMENT AREA REINFORCEMENT: PLACEMENT AREA FORMWORK: ACCEPTABLE FOR ALIGNMENT & CLEANLINESS. FREE OF DEBRIS & STANDING WATER/ICE/SNOW. CLEANLINESS & COVER ACCEPTABLE. PROPERLY SIZED & LOCATED. PLACEMENT WEATHER PROTECTION: FOOTING: NORTH WALL FOOTING: EAST WALL; SOUTH WALL, EAST HALF PLACEMENT LOCATION OF LOAD # FOOTING: SOUTH WALL, WEST HALF; WEST WALL 0.00 45 C O N C R E T E F I E L D I N S P E C T I O N & C O M P R E S S I O N T E S T R E S U L T S 0.00 TEST AGE 3000 0 JOINTA-GALUSHA CONCRETE, INC. 0 ULTIMATE 07/07/20 4.00 0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 59,300 42,500 0 0 58,400 56,850 4: 0.0 5: 6: 7: 8: 1: FILE 2: SUPPLIER 3: TIME CONC. BATCHED / ARRIVED: 40,750 DAYS UNLESS NOTED ALL TESTING IAW: ASTM: C31, C138, C143, C172, C173, C231, C470, C567, C617, C1064 DISCREPANCIES & REMARKS: 0.0 LAB CYLINDER CONTROL NUMBERS: WATER: 0 0 DESIGN STRENGTH & FORMULA: IF APPLICABLE: DELIVERED LOAD NUMBER: TRUCK NUMBER / TICKET NUMBER: YARDAGE DELIVERED / SUBTOTAL: CONCRETE TEMP. (F) (SPEC: SLUMP OF CONCRETE INTO PUMP: TIME PLACEMENT BEGAN / ENDED: CONCRETE AGE ( HOURS ) (SPEC: SLUMP ON ARRIVAL (INCHES): PROJECT: CONSTRUCTION TECHNOLOGY MR. TIMOTHY BARTLETT UNITED CEREBRAL PALSY ASSOCIATION OF THE TRI-COUNTIES C/O CENTER FOR DISABILITY SERVICES, INC. 22 CORPORATE WOODS BOULEVARD, 5th FLOOR ALBANY, NEW YORK 12211 NEW RESPITE CARE FACILITY, QUEENSBURY, NEW YORK RobertBehanRobertBehanRobertBehanRobertBehan APPLIED LOAD 3 07/06/20 100.180 200858 80's: CLEAR 4 William Street, Ballston Lake, New York 12019 Phone: (518) 399-1848 Email: constructiontech@live.com CLIENT: REPORT NUMBER: : PAGE #: 2 INSPECTION DATE: OUR FILE NUMBER:5 INSPECTOR & TEST SET: DAVE CASAW #5 ATT'N: AMBIENT WEATHER: OUR FILE LOCATION: 4 : 0 0 0 0 0 0 4 0 0 0 4912 / 840061 0 0 0 0 0 0 8.00 / 41.00 3 0.00 0 0.00 0 0.00 0 0.00 0 2.04 / 2.32 0 ## 0.00 0 0.00 0 0.00 0 0.00 0 2.33 / 2.58 # 0 0.00 0 0.00 ## 0.00 0 0.00 0.00 MAX: 1.50 )2 0.90 0 0 0.00 0 0 0.00 0 0.04 5.50 2 0.00 0.00 0 0.00 0.00 0 WATER ADDED ONSITE (GALLONS):0.00 0 0.00 0 0.00 0 WATER ADDED AT DISCRETION OF:0.00 # 0.00 ##0.00 0.00 5.50 0.00 0.00 PLACEMENT SLUMP (INCH) (SPEC: - 5.00 )5.50 1 0.00 0 0.00 0 ENTRAINED AIR ( % VOL) (SPEC: - 7.00 )0.00 0 0.00 0 0.000000 UNIT WEIGHT (PCF) (SPEC:-0.00 )0.00 0 0.00 0 0.00 0 90 ) 83 0 0 0 0 0 NUMBER OF TEST SPECIMEN CAST:0 0 0 0 0 0 0 0 0 0 0 0 0 1: CONCRETE SUPPLIER:CONCRETE TEST CYLINDER COMPRESSIVE RESULTS PER: ASTM: C39 P.S.I. @ 28 DAYS :UNLESS OTHERWISE NOTED ALL CYLINDERS RECEIVED: CEMENT:LBS.CYLINDER TEST UNIT CEMENT:LBS. NUMBER DATE P.S.I. GAL. COARSE AGGREGATE #1: LBS.0 07/13/20 7 1440 X COARSE AGGREGATE #2: LBS.0 07/13/20 7 1500 X COARSE AGGREGATE #3: LBS.0 08/03/20 28 0 X FINE AGGREGATE: LBS.0 08/03/20 28 0 X ADMIXTURE #1: OZS.0 08/03/20 28 0 X ADMIXTURE #2: OZS.0 01/00/00 SPARE 0 X ADMIXTURE #3: OZS. AIR ENTRAINING AGENT: OZS.0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X REPORT DISTRIBUTION:0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 01/00/00 0 0 X RESPECTFULLY SUBMITTED,0 0 0 0 01/00/00 0 0 X CONSTRUCTION TECHNOLOGY 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X ROBERT BEHAN, (NICET)0 0 0 0 01/00/00 0 0 X MANAGER TECHNICAL SVCS.0 0 0 0 01/00/00 0 0 X CONSTRUCTION TECHNOLOGY UNITED CEREBRAL PALSY ASSOCIATION OF THE TRI-COUNTIES 3 C/O CENTER FOR DISABILITY SERVICES, INC.07/06/20 22 CORPORATE WOODS BOULEVARD, 5th FLOOR 100.180 ALBANY, NEW YORK 12211 MR. TIMOTHY BARTLETT 80's: CLEAR PROJECT:NEW RESPITE CARE FACILITY, QUEENSBURY, NEW YORK 0 C O N C R E T E F I E L D I N S P E C T I O N & C O M P R E S S I O N T E S T R E S U L T S PLACEMENT LOCATION OF LOAD # FOOTING: INTERIOR PIER FOOTINGS 0 0 DELIVERED LOAD NUMBER: TRUCK NUMBER / TICKET NUMBER: YARDAGE DELIVERED / SUBTOTAL: TIME CONC. BATCHED / ARRIVED: TIME PLACEMENT BEGAN / ENDED: CONCRETE AGE ( HOURS ) (SPEC: SLUMP ON ARRIVAL (INCHES): SLUMP OF CONCRETE INTO PUMP: IF APPLICABLE: 0.00 4.00 0.00 CONCRETE TEMP. (F) (SPEC:45 LAB CYLINDER CONTROL NUMBERS: DISCREPANCIES & REMARKS: CONTRACTOR NOTIFIED: LOAD 4: SLUMP PLACEMENT AREA REINFORCEMENT: CLEANLINESS & COVER ACCEPTABLE. PROPERLY SIZED & LOCATED.PER DRAWING: S-202, DETAIL: 5 PLACEMENT AREA FORMWORK: ACCEPTABLE FOR ALIGNMENT & CLEANLINESS. FREE OF DEBRIS & STANDING WATER/ICE/SNOW. GENERAL CONSTRUCTION PRACTICE: CONCRETE PROPERLY CONSOLIDATED. NO VISUAL EVIDENCE OF SEGREGATION OR COLD JOINTS. PLACEMENT WEATHER PROTECTION: PROPER HOT OR COLD WEATHER CURING PROTECTION FOR AMBIENT CONDITIONS IS AVAILABLE ONSITE. UNLESS NOTED ALL TESTING IAW: ASTM: C31, C138, C143, C172, C173, C231, C470, C567, C617, C1064 JOINTA-GALUSHA CONCRETE, INC. DESIGN STRENGTH & FORMULA: 3000 07/07/20 0 TEST AGE ULTIMATE 0 DAYS APPLIED LOAD WATER:0.0 40,750 42,500 0 0 0 0.0 0 0 0 0.0 0 0 0 1: FILE 5:0 2: SUPPLIER 6:0 3:7:0 RobertBehanRobertBehanRobertBehanRobertBehan 0 0 0 4:8:0 0 0 0