Loading...
New Respite Care Facility concrete test report 74 William Street, Ballston Lake, New York 12019 Phone: (518) 399-1848 Email: constructiontech@live.com CLIENT: REPORT NUMBER: : PAGE #: 1 INSPECTION DATE: OUR FILE NUMBER:5 INSPECTOR & TEST SET: DAVE CASAW #5 ATT'N: AMBIENT WEATHER: OUR FILE LOCATION: 1 : PLACEMENT LOCATION OF LOAD # 2 : 0 0 0 1 2 0 0 4912 / 840735 4974 / 840736 0 0 0 11.50 / 11.50 2 11.50 / 23.00 2 0.00 0 0.00 0 12.49 / 1.15 0 ##1.13 / 1.35 0 0.00 0 0.00 0 1.20 / 1.42 # 1 1.46 / 2.04 ## 0.00 0 0.00 0.00 MAX: 1.50 )12 0.88 0 1 0.85 0 0 0.00 0 0.49 4.00 1 0.13 4.00 2 0.00 0.00 0 WATER ADDED ONSITE (GALLONS):0.00 0 0.00 0 0.00 0 WATER ADDED AT DISCRETION OF:0.00 # 0.00 ##0.00 0.00 4.00 4.00 0.00 PLACEMENT SLUMP (INCH) (SPEC: - 5.00 ) 4.00 0 4.00 0 0.00 0 ENTRAINED AIR ( % VOL) (SPEC: - 3.00 ) 1.10 0 0.00 0 0.000400800 UNIT WEIGHT (PCF) (SPEC:-0.00 ) 151.81 0 0.00 0 0.00 0 90 ) 82 0 83 0 0 0 NUMBER OF TEST SPECIMEN CAST:6 0 0 0 0 201616 - 201621 0 0 0 0 0 0 0 CONCRETE SUPPLIER:CONCRETE TEST CYLINDER COMPRESSIVE RESULTS PER: ASTM: C39 P.S.I. @ 28 DAYS :UNLESS OTHERWISE NOTED ALL CYLINDERS RECEIVED: CEMENT:LBS.CYLINDER TEST UNIT CEMENT:LBS. NUMBER DATE P.S.I. GAL. COARSE AGGREGATE #1: LBS.201616 08/07/20 7 4360 0 COARSE AGGREGATE #2: LBS.201617 08/07/20 7 4110 0 COARSE AGGREGATE #3: LBS.201618 08/28/20 28 5120 0 FINE AGGREGATE: LBS.201619 08/28/20 28 4900 0 ADMIXTURE #1: OZS.201620 08/28/20 28 5160 0 ADMIXTURE #2: OZS.201621 01/00/00 SPARE 0 X ADMIXTURE #3: OZS. AIR ENTRAINING AGENT: OZS.0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X REPORT DISTRIBUTION:0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 01/00/00 0 0 X RESPECTFULLY SUBMITTED,0 0 0 0 01/00/00 0 0 X CONSTRUCTION TECHNOLOGY 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X ROBERT BEHAN, (NICET)0 0 0 0 01/00/00 0 0 X MANAGER TECHNICAL SVCS.0 0 0 0 01/00/00 0 0 X RobertBehanRobertBehanRobertBehanRobertBehan APPLIED LOAD 7 07/31/20 100.180 201616 80's: CLEAR PROJECT: CONSTRUCTION TECHNOLOGY MR. TIMOTHY BARTLETT UNITED CEREBRAL PALSY ASSOCIATION OF THE TRI-COUNTIES C/O CENTER FOR DISABILITY SERVICES, INC. 22 CORPORATE WOODS BOULEVARD, 5th FLOOR ALBANY, NEW YORK 12211 NEW RESPITE CARE FACILITY, QUEENSBURY, NEW YORK IF APPLICABLE: DELIVERED LOAD NUMBER: TRUCK NUMBER / TICKET NUMBER: YARDAGE DELIVERED / SUBTOTAL: CONCRETE TEMP. (F) (SPEC: SLUMP OF CONCRETE INTO PUMP: TIME PLACEMENT BEGAN / ENDED: CONCRETE AGE ( HOURS ) (SPEC: SLUMP ON ARRIVAL (INCHES): LAB CYLINDER CONTROL NUMBERS: WATER: 0 0 DESIGN STRENGTH & FORMULA: 3: TIME CONC. BATCHED / ARRIVED: 54,800 DAYS UNLESS NOTED ALL TESTING IAW: ASTM: C31, C138, C143, C172, C173, C231, C470, C567, C617, C1064 DISCREPANCIES & REMARKS: 0.0 4: 0.0 5: 6: 7: 8: 1: FILE 2: SUPPLIER 0 0 0 61,600 51,650 0 0 64,250 64,800 0 0 0 0 0 0 0 0.0 0 0 0 0 JOINTA-GALUSHA CONCRETE, INC. 0 ULTIMATE 08/03/20 0.00 C O N C R E T E F I E L D I N S P E C T I O N & C O M P R E S S I O N T E S T R E S U L T S 0.00 TEST AGE 4000 SLAB ON GRADE: NORTH CRAWL SPACE & SOUTH CRAWL SPACE, WEST HALF SLAB ON GRADE: WEST CRAWL SPACE & SOUTH CRAWL SPACE, EAST HALF PLACEMENT LOCATION OF LOAD # 0 0.00 45 PROPER HOT OR COLD WEATHER CURING PROTECTION FOR AMBIENT CONDITIONS IS AVAILABLE ONSITE. PER DRAWING: S-202, DETAIL: 5 GENERAL CONSTRUCTION PRACTICE: CONCRETE PROPERLY CONSOLIDATED. NO VISUAL EVIDENCE OF SEGREGATION OR COLD JOINTS. PLACEMENT AREA REINFORCEMENT: PLACEMENT AREA FORMWORK: ACCEPTABLE FOR ALIGNMENT & CLEANLINESS. FREE OF DEBRIS & STANDING WATER/ICE/SNOW. CLEANLINESS & COVER ACCEPTABLE. PROPERLY SIZED & LOCATED. PLACEMENT WEATHER PROTECTION: