Loading...
2005-892 TOWN OF QUEENSBUIRY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20050892 Date Issued: Thursday, December 22, 2005 This is to certify that work requested-to be done as shown by Permit Number P20050892 has been completed. Tax Map Number: 523400-226-019-0001-058-000-0000 Location: 32 NORTH Ln Owner: JOSEPH PARISI Applicant: _ JOSEPH PARISI This structure may be occupied as a: Septic Alteration Residential By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050892 Application Number: A20050892 Tax Map No: 523400-226-019-0001-058-000-0000 Permission is hereby granted to: JOSF.PH PARTST For property located at: 32 NORTH Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JOSEPH PARISI 32 NORTH Ln Septic Alteration Residential Total Value LAKE GEORGE, NY 12845 Contractor or Builder's Name /Address Electrical Inspection Agency SANITARY SEWER DAN DRELLOS PO BOX 224 GLENS FALLS NY Plans&Specifications 2005-892 SEPTIC ALTERATION $25.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Friday, November 17, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To T;sftb ; rra ovember 17, 2005 SIGNED BY 9 for the Town of Queensbury. Director of Building&Code Enforcement Application for Permit—,Septic Disposal System Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761-8256 1, OWNER INFORMATION: / Office'Use Location of installation: File Permit No. �� Gp� Tax Map No. / / � Fee Paid Owner's Name: (f CP,( / l-............................................................................................................................ Address: �- ILA `7� / k A!'� 2, INSTALLER'S NAME.: r . Gt.o/ '�,� PHONE NO. 7 3, RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply #of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of Bedrooms x . Computation = Total Daily Flow 1980 or older .. x 150 gal/bdrm = 1980- 1991 x 13.0 gal/bdrm = z 1991 -present x 1110 gaUbdrm _ Garbage Grinder Installed yes._ A, cl,D Ta CA3 F(P,( , Spa or Hot Tub Installed. yes` 1� 4. PARCEL INFORMATION: (circle applicable information& indicate measurements) Topography Soil Nature Ground Water Bedrock or Impervious Material Domestic Water Supply sand,,.,. at what depth at what depth municipal a feet feet well Steep slope clay if well; water supply �%slope other from anyseptic-.system depth: absorption i�zfr. other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: f`� minute per inch 5, PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons.to the size of the septic stank and leach field for each Garbage Grinder, Spa or Whirlpool Tub. SepticGTank/ -gallon (min,size 1)-000 gal,) Tile Field: each trench ft, Total System Length: jr, Seepage Pit(s): number.of size of each: ft. by .RF—CEIVED Size of Stone to be used: # / depth or thickness feet NOV 15 2005 Bed System Size: r x TOWN �UINL OF QU D CODE � Y Alternative System:�� h�o- length andlor size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: gallons /TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. ?. SIGNATURE & INFORMATION.FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in re'li'amce upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void.' I have read the regulations with respect to this.application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance, Signature of responsible person Date Town of Queensbury Sewers and Sewage Disposal Chapter Appendix C ABSORPTION FIELD SEPARATION REQUIREMENTS .r_ ...... pmb .-^ el j I S pric, 5.1W I Appendix C ABSORPTION FIELD SEPARATION REQUIREMENTS �11W 04 . t � c I �1� IMML, i Septic Inspection .Report Office No. (518)761-8256 Date Inspectiynr� eQueensbury Building&Code Enforcement Arrive: t: am/pm742 Bay Rd., Queensbury,NY 12804 Inspector's InNAME: -' _LOCATION: f"32, 0 n�l4 I A .F Z -T RECHECK: Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance Well separation distance ft. Other wells: $} Absorption Field: Total length ft. Length of each trench $. ` �����E �,` V�� -Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/Pit Opening Sealed: Y/N/Partial End Caps Location/Separations Foundation to tank ft. Foundation to absorption Separation of Pits ft. Conforms as per Plot lan Y N Engineer Report and s-Built Y N ocation of System on Property: Front Rear Left Side Right Side ;Middle Fro Middle Rear S stem St Ap roved artial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved Last revised 1/6/05 �-TEC�;21 2005 4: 15PM HP LRSERJET 3200 p. 4 169 Haviland Road, Queensbury,NY 12804 Phone-518-745-4400 Fax -518-792-8511 December 21, 2005 Job#49177 Mr. Dave Hatin Town of Queensbury 742 Bay Road Queensbury,NY 12804 RE: Parisi Residence—32 North Lane,Assembly Point Replacement Septic System Inspection Gentlemen: This letter is to inform ,you that we inspected the completed septic system for the Parisi Residence at 32 North Lane in the Town of Queensbury on November 18,2005. The septic system as installed was for a three bedroom house and consisted of an existing 1,250 gallon septic tank, a new pump station, a new 1 '/2" force main and a new 10 foot wide by 55 foot long absorption bed. The absorption bed was constructed with stone and 2 — 50 foot long perforated pipe laterals. The system conforms to the requirements of the approved design drawings and sewer variance conditions. Please call me if you have any questions or concerns. Sincerely, Thomas.R. Center Jr., PE COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.() Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No........................................Cert. No _ 9 3 7 5 3 Cut-in Card No.................. ... .... 1 ,� r Location......5.r .11 .... ......... ...........................................�,%.......... Installation Consisting of...S-911W.�..../ ! '?"'�'9`�. - ! .. ................................ ................................................(.'.f.. / .......................................................................................... .................................................................................................................................................................................... InstalledBy........K:!..S .Y& .........................Lie.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of makin msp ctions at any time, and if its rules are violated,the Co y shall have the right t re o e thi certif ate �/ Z -..� ` Date..... ....................... INSPECTOR......... ........ .......................................... ........................... Memher N_RP_A__ Septic Inspection Report /� Office No. (518)761-8256 Date Inspection re est r cei' ve P Queensbury Building&Code Enforcement Arrive: 7=/p / part: 742 Bay Rd., Queensbury,NY 12804 Inspector's Imt als: -lam y NAME: Ialm IT NO.: LOCATION: >)7 \ ��0ETB LJA�)f G,SPECTON: — RECHECK: Comments and/or diagram Soil Typ `Oarid-/Loam/Clay _ Type of a er. unicipal ell Water Waterline separation distance ft. Well separation distance -7, ft. ,k Other wells: ft. -Absorption Field: Total length Length of each trench G r ft. Depth of trenches ft. Size of Stone XY 7— Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box C. -- ��- L� Distribution Box to Field/Pit + Opening Seale : Y Partial End Caps — Location/Separations Foundation to tank Foundation to absorption Separation of Pits ft. C�rnu-as-per Plot Plan 'iw Y Engineer Re o and As-Built v Y V N Location of System on Property: c�pieft Side Right Side Middle Front Middle Rear System Use Stat d: ( U} U �C� ji ZJ Approved �"`�� (( ������, ..,, _ I Partial Approved an"eeds to be re-inspecte1please ca�he Building&Codes Office Disapproved Last revised 1/6/O5 ��— LANDS N/ OF ZYLOWSKI 112.5 SN EPARKIG M BE STONE LIMITS OF NEV FILL MATERIAL SOILS DATA TEST PIT r / • / 0-,3## TOP SOIL TO PROPERTY LINE `� NEW PUMP STA71ON 3-51 LOAMY MEDIUM FINE SILTY SAND (COMPACT) • ; "' ' (COMPACT) LANDS N/F 51-63" FINE SILTY SANG ( EXISTING 1250 GAL OF PARISI O SEPTIC TANK MOIST ® 36" - L 2 - 50' LONG ABSORPTION Q'(BI " L, l LA ALS PERCOLATION RATE - 1 IN 14 MINUTES, 52 SECONDS PROJECT LOCATION ` ITEST PIT BY NACE ENGINEERING - 08 6 05 7NECTED i � ew ni I NEW 10' WIDE X 55' LONG MIN. PERCOLATION TEST BY NACE ENGINEERING IN A 12 INCH DEEP HOLE • '® ABSORPTION BED . EXISTING 3 BEDROOM -� �.• „ HOUSE o LANDS N/F AND A TEST DEPTH OF 6" ON 8/6/05 • , OF CHRYS 4 wtl �a • ASPAHLT % ROAD SEPTIC SYSTEM DESIGN j 4 100' WELL SETBACK LIMIT ASPAHLT DESIGN FLOW - EXISTING 3 BEDROOM HOUSE �= - • ' p IIRIVEWAY • - 3 BEDROOMS ® 110 GAL./DAY/BDRM = 330 GPD - - - - - - - LANDS N/F • OF TOBIN - L' ► �� SEPTIC TANK - USE EXISTING 1,250 GAL. TANK a PROPERTYC \ 0 LINE ABSORPTION FIELD - EXISTING FAILED SEPTIC SYSTEM - USE NEW PUMP STATION & REPLACEMENT ABSORPTION BED SYSTEM. M - AT NYSDOH APPLICATION RATE OF 0.60 GAL/DAY/SF, LOCATION PLAN 550 S.F. OF ABSORPTION BED REQUIRED. 1 - USE 10' WIDE BY 55' LONG (550 S.F.) ABSORPTION BED W WITH 2 - 45' LONG LATERAL. URY �7 TOWN OF OU ENSB o NORTH LANE D BUILDING & C D T. _ LANDS N/F d REVIEWED BY , DATE / OF TEDESCHI TT 11 f1~ O 1.0' MIN. E-4 O c� EXISTING HOUSE FROM TOE OF SLOPE Z ON PUBLIC WATER SUPPLY TO PROPERTY LINE a TOWN OF QUEENSBURY BUILDING DEPARTMENT � c C* � � LANDS N/F Based on odr limited examination, �, OF LANDS N/N SWALE AT UPHILL SIDE comppliance with our comments shall OF BED TO DRAIN RUNOFF not be construed as indicating the g.; LANDS N/F SLOPED TO DRAIN plans and specifications are in full OF DUBIN AWAY FROM BED compliance with the Suildina Codes- a Of New Yap; Stfe. W z Cd EXISTING HOUSE ABANDONED WELL. a ON PUBLIC WATER SUPPLY CUT, CAPPED & BURIED -1 , 9/2005 6" TO 12" BACKFILL EARTH IF 3Cr FILL ILTER FABRIC 1• W ' w OR GEOTEXTILE 2411 L) 04o 2" MIN. 4" PERFORATED MIN. ti a EARTH LATERAL EARTH FILL ion F-0990 00 FILL a 3/4" TO 1 1/2" W w CRUSHED STONE , 1" a 20• +/ /-- EXISTING GRADE 6w 5 -0 36" MIN 5# . '- NOTE: SITE PLAN LAYOUT DEVLEOPED BASED ON ENGINEERS _ DIMENSIONS MEASURED IN THE FIELD. TOWN OF QUEENSBURY MAXIMUM TAX MAPS AND FRONT CORNERS BASED ON OWNERS DESCRIPTION. GROUNDWATER �.y. ELEVATION Fr-1 SHALLOW ABSORPTION BED SECTIONco W 0 CONCRETE OR STONE N.T.S. (�� N FINISHED 4MINE R ABOVE ALL �-� / GRADE ED COVERS MENDED. NOTE: ACCESS HATCH FILL USED IN AREA OF ABSORPTION TRENCH SHALL BE p INLET BAFFLE 1R OVER FINE SANDY LOAM WITH AN IN-PLACE PERC e,>nN Rem OF I i , ; f, ALL STRUCTURES 10 TO 15 MINUTES PER INCH. ELECTRICAL t 'v BOX JUNCTION PLACE FILL IN 12 INCH LIFTS AND LIGHTLY COMPACT WITH t ram Z u TRACK EQUIPMENT. DO NOT-ALLOW RUBBER TIRE EQUIPMEN r ,.: (,� Q OR TRUCKS IN ABSORPTION TRENCH AREA. ENGINEER M PERFORM PERCOLATION TEST IN n UBMERSI E :: ALL OUTLET INVERTS ' PUMP 4 PVC ••. TTO� YSE AT E TO CONSTRUCTION OF ABSORPTION SYSTEM a ELEVATION. ALARM ON •. . E " PEA GRAVEL 0 ' 1 1/2 FORCE MAIN 10 " SLOPE TO DRAIN DISTRIBUTION BOX INSTALLATION OF DISPOSAL FIELDS j MP ON � � DIA. I I BACK TO PUMP STATION N.T.S. 1. CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING, ' Z PUMPS 0 CHECK VIP AND SHALL BE IN ACCORDANCE WITH THE N.Y.S. Q C� 1 : DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS, ARECC V 'd ASTM F481-76 INSTALLATION OF THERMOPLASTIC PIPE AND ED CONCRETE TO BE CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS. NOV 15 W ° TROWEL FINISHED - — 12" MAX. ����--���loll I... 2005 W 4'-0" I.D. PRECAST CONCRETE '1-I(I1= _ 2. NO HEAVY EQUIPMENT SHALL. BE ALLOWED WITHIN THE LIMITSOWN pF OUEENSBURy b 6" MIN. OF THE DISPOSAL FIELD AFTER PIPE INSTALLATION HAS BEG 1t6NG qNp COp H s~ MERCURY FLOAT EFFLUENT PUMP E MANHOLE WITH INTEGRAL BASE o AND FLAT SLAB TOP. SWITCH WITH 3. AFTER EXCAVATION TO THE DEPTHS REQUIRED, THE WALLS AND � r.., AS MANUFACTURED BY FORT MILLER WEIGHT (TYP.) FLOOR OF THE BED SHOULD BE CLEANED •� OR EQUIVALENT " Z NTERCONNECT ENDS y 6 MIN. - AND RAKED TO ACHIEVE (NO LADDER RUNGS) BOTTOM OF BED 4" PERFORATED PVC OF LATERALS SMEARED SECTIONS OF TRENCH. N SURFACE AND TO LOOSEN W , LATERAL, LAID LEVEL N ►�+ 4. PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND FILTER PUMP STATION STANDARD ABSORPTION BED PROFILE FABRIC SHALL BE AS SHOWN, AND CARE SHALL BE W �p N.T.S. EXERCISED TO AVOID INCLUSION OF FINE GRAINED SOILS AND 1. PUMP TO BE EFFLUENT PUMP RATED AT A MINIMUM OF 30 GPM N.T.S. OTHER WASTE MATERIAL IN THE STONE AND PIPE. AT 20 FEET TOTAL DYNAMIC HEAD. PUMP TO BE 1/3 HP GOULDS 5. THE PIPE SHOULD BE LAID AT THE GRADES AND TO THE MODEL 3885WE03L OR EQUAL. RELATIONSHIPS SHOWN ON THIS DRAWING, MAINTAINING STRAIGHT 2. PUMP CONTROL PACKAGE TO BE SUPPLIED BY MANUFACTURER. CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS Datei SEPTEMBER, 2005 •AUDIBLE AND VISIBLE ALARM TO BE ACTIVATED BY ALARM FLOAT OR OTHER UNSUITABLE CONDITIONS. THE PIPE SHALL BE LAIDWITH THE HOLES DOWN IN ALL CASES. Scoter AS NOTED 3. PUMP CYCLE VOLUME = 47 GALLONS ( 80% OF ABSORPTION FIELD VOLUME). 6. THE DISPOSAL FIELD SHALL BE GRADED TO SHED RAINFALL AND TO DIVERT SURFACE RUNOFF FROM ADJACENT AREAS AWAY FROM THE DISPOSAL FIELD. 7. NO PART OF THE DISPOSAL SYSTEM SHALL BE INSTALLED UNDER DRIVEWAYS. 49177 I ,OF1 LANDS N/ OF ZYLOWSKI 112.5' EXISTING CRUSHED STONE O W PARKING TO BE REMOVED SOILS DATA LIMITS OF NEW FILL MATERIALCL Q Jr �i TEST PIT ' ze cc � �' / 0-3" TOP SOIL ® O o PROPERTY LINE NEW PUMP STATION 3-51" LOAMY MEDIUM FINE SILTY SAND (COMPACT) �r � j LANDS N/F 51-63" FINE SILTY SAND (COMPACT) / EXISTING 1250 GAL OF PARISI ,. SEPTIC TANK MOIST 0 36" to 2 - 50' LONG ABSORPTION P� PERCOLATION RATE - 1" IN 14 MINUTES, 52 SECONDS PROJECT LOCATZON I�ITEROONCT» u ALS ' TEST PIT BY NACE ENGINEERING - 08/6/05 R 1 o NEW 10' WIDE X 5W LONG MUN. PERCOLATION TEST BY NACE ENGINEERING IN A 12 INCH DEEP HOLE •,,, +® 0 2 ABSORPTION BM , EXISTING 3 BEDROOM oMMILLUM CS i HOUSE ., LANDS N/F AND A TEST DEPTH OF 6„ ON 8/6/05 OF CHRYS ASPAHLT SEPTIC SYSTEM DESIGN ,.,��''� ••• "* ' `!.��'' ROAD 100 WELL DESIGN FLOW - EXISTING 3 BEDROOM HOUSE ..-. ' SETBACK LIMIT DRIVEWAY — 3 BEDROOMS 0 110 GAL./DAY/BDRM = 330 GPD LANDS N/F SEPTIC TANK - USE EXISTING 1,250 GAL. TANK OF TOBIN -i-I -9 �-PROPERTY ABSORPTION FIELD - EXISTING FAILED SEPTIC SYSTEM LINE - USE NEW PUMP STATION & REPLACEMENT ABSORPTION BED SYSTEM. Z7 - AT NYSDOH APPLICATION RATE OF 0.60 GAL/DAY/SF, LOCATION PLAN M 550 S.F. OF ABSORPTION BED REQUIRED. "♦.,♦ - USE 10' WIDE BY 55' LONG (550 S.F.) ABSORPTION BED W a —I WITH 2 - 45' LONG LATERAL. TOWN OF OU ENSBURY NORTH LANE p BUILDING & C T. 1> d REVIEWED BY LANDS N/F DATE j " '^ OF TEDESCHI V; 1.0 MIN. [-1 F� EXISTING HOUSE FROM TOE OF SLOPE QI Z z Q� ON PUBLIC WATER SUPPLY TO PROPERTY LINE TOWN OF QUEENSBURY BUILDING DEPARTMENT w c 02 � � Based on oUr limited examination, comppliance with our Comments shall LANDS N/F SWALE AT UPHILL SIDE not be construed as indicating the OF KILLEEN OF BED TO DRAIN RUNOFF SLOPED TO DRAIN plans and specifications are in full [�1 LANDS N/F OF DUBIN AWAY FROM BED compliance w}Ut the 8uildinq Codes �j of New Yc.. Stile, F-1 W a z od EXISTING HOUSE ABANDONED WELL, ON PUBLIC WATER SUPPLY CUT, CAPPED & BURIED 6" TO 12" BACKFILL EARTH �� 3 � Cr 9/2005 FILL LTER FABRIC 1 W w OR GEOTEXTILE 1' � 1 " 24 0 2" MIN. 4A PERFORATED MIN. EARTH LATERAL EARTH a H FILL (Oa p o 3/4" TO 1 1/2" FILL w CRUSHED STONE 1" - 20' +/- EXISTING GRADE 36" MIN. NOTE: SITE PLAN LAYOUT DEVLEOPED BASED ON ENGINEERS —_ DIMENSIONS MEASURED IN THE FIELD, TOWN OF QUEENSBURY MAXIMUM U� TAX MAPS AND FRONT CORNERS BASED ON OWNERS DESCRIPTION. GROUNDWATER ELEVATION SHALLOW w O ABSORPTION BED SECTION � � CONCRETE OR STONE N.T.S. (` �G�� FINISHED MARKER ABOVE ALL "" GRADE BURRIED COVERS NOTE: �..� RECOMMENDED. FILL USED IN AREA OF ABSORPTION TRENCH SHALL RE ACCESS HATCH w O 0 INLET BAFFLE 12" MIN. OVER OVER FINE SANDY LOAM WITH AN IN-PLACE PERCOLATION RA E .OF n 4 •� e "1 :v 4 ALL STRUCTURES 10 TO 15 MINUTES PER INCH. , ; l a ELECTRICAL PLACE FILL IN 12 INCH LIFTS AND LIGHTLY COMPACT WITH JUNCTION 1( ,., ,• Z BOX TRACK EQUIPMENT, DO NOT ALLOW RUBBER TIRE EQUIPMEN OR TRUCKS IN ABSORPTION TRENCH AREA, ENGINEER TO PERFORM PERCOLATION TEST IN FILL PRIOF UBMERSI E ,: ALL OUTLET INVERTS 4 PVC PUMP TO SEj.E�ETO CONSTRUCTION OF SYSTEM. _ OT Ili VATION. O ALARM ON E " PEA GRAVEL INSTALLATION OF DISPOSAL FIELDS 0 SLOPE TO DRAIN DI 1 1 2 FORCE MAIN STRIBUTION BOX G7 PUMP ON `° DIA. 14 BACK TO PUMP STATION N.T.S. 1. CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING, Z AND SHALL BE IN ACCORDANCE WITH THE N.Y.S. 1---1 DEPARTWENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS, 'b PUMPS OF tO CHECK VA L; ASTM F481-76 INSTALLATION OF THERMOPLASTIC PIPE AND ECEIVED 1 - '• N 1��•'�•'• • • CONCRETE TO BE _ — — — - CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS. NOV 1 5 2005 w w IZZ TROWEL FINISHED 12" MAX. ����_��� „I111- �I_II _ 2. NO HEAVY EQUIPMENT SHALL BE ALLOWED WITHIN THE LIMITTOWN OF QUE •b ' • - � OF THE DISPOSAL FIELD AFTER PIPE INSTALLATION HAS BE ILD(NG ANpfvSi3URY � a 4'-0" I.D. PRECAST CONCRETE MERCURY FLOAT EFFLUENT PUMP " MANHOLE WITH INTEGRAL BASE SWITCH WITH 6 MIN. 3. AFTER EXCAVATION TO THE DEPTHS REQUIRED, THE WALLS AND CODEed AND FLAT SLAB TOP. WEIGHT (TYP.) FLOOR OF THE BED SHOULD BE CLEANED AS MANUFACTURED BY FORT MILLER " i NTERCONNECT ENDS AND RAKED TO ACHIEVE AN EVEN SURFACE AND TO LOOSEN OR EQUIVALENT 6 MIN. (NO LADDER RUNGS) BOTTOM OF BED 4" PERFORATED PVC N OF LATERALS SMEARED SECTIONS OF TRENCH. w �' LATERAL, LAID LEVEL 4. PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND FILTER w C� FABRIC SHALL BE AS SHOWN, AND CARE SHALL BE co PUMP STATION STANDARD ABSORPTION BED PROFILE EXERCISED TO AVOID INCLUSION OF FINE MATERIAL N THE STONE GRAINEDND SOILS AND N.T.S. N.T.S. OTHER 1. PUMP TO BE EFFLUENT PUMP RATED AT A MINIMUM OF 30 GPM 5. THE PIPE SHOULD BE LAID AT THE GRADES AND TO THE AT 20 FEET TOTAL DYNAMIC HEAD. PUMP TO BE 1/3 HP GOULDS RELATIONSHIPS SHOWN ON THIS DRAWING, MAINTAINING STRAIGHT MODEL 3885WE03L OR EQUAL. CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS Datei SEPTEMBER, 2005 2. PUMP CONTROL PACKAGE TO BE SUPPLIED BY MANUFACTURER. OR OTHER UNSUITABLE CONDITIONS. THE PIPE SHALL BE LAID AUDIBLE AND VISIBLE ALARM TO BE ACTIVATED BY ALARM FLOAT WITH THE HOLES DOWN IN ALL CASES. Scoter AS NOTED 3. PUMP CYCLE VOLUME = 47 GALLONS ( 80% OF ABSORPTION FIELD VOLUME). 6. THE DISPOSAL FIELD SHALL BE GRADED TO SHED RAINFALL AND TO DIVERT SURFACE RUNOFF FROM ADJACENT AREAS AWAY FROM THE DISPOSAL FIELD. 7. NO PART OF THE DISPOSAL SYSTEM SHALL BE INSTALLED UNDER DRIVEWAYS. 49177 »tT1OF1