2005-921 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number. P20050921 Date Issued: Thursday, September 07, 2006
This is to certify that work requested to be done as shown by Permit Number P20050921
has been completed.
Tax Map Number. 523400-308-014-0001-030-000-0000
Location: 11 AMETHYST Dr
Owner. JAMES HICKS
Applicant: JAMES HICKS
This structure maybe occupied as a:
Residential Addition By Oder of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20050921 Application Number: A20050921
Tax Map No: 523400-308-014-0001-030-000-0000
Permission is hereby granted to: JAWS HICKS
For property located at: 11 AMETHYST Dr
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: JAMES HICKS
NOELLE STEVENS Residential Addition $19,469.00
Total Value $19,469.00
11 AMETHYST Dr
QUEENSBURY, NY 12804-0000
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2005-921
279 SQ FT RESIDENTIAL ADDITION
$75.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Friday, December 29, 2006
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the T "o uee rY es y,December 28, 2005
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
.-i-i i i-i---i i i i ii------
Community Development Office ;
own of Queensbury • 742 Bay Road - Queensbury, New York •12804 ;
1
Marilyn Ryba, Executive Director• David Hatin, Director of-Building&Codes
Craig Brown, Zoning Administrator ;
� I
WINDOW SCHEDULE -
JOB SITE/ADDRESS: S l eV G►1 S - C i` me 7�c Us7` DATE: /2 - z Z-65
OWNER: lVo P Ll? s t LUeg s APPLICATION NO.:
WINDOW- UNIT OR CLEAR
CLEAR
WINDOW STOCK ROUGH ROUGH SQ.FT. OPENING
NO.OR WINDOW SQ.FT. OPENING SPECIAL HARDWARE OR
MANUFACTURER NUMBER OPENING OPENING EGRESS/CLEAR HEIGHT
LETTER NAME MODEL/TYPE CALL WIDTH HEIGHT VENT OPENING WIDTH IN IN INSTRUCTIONS
ON PLAN / SIZE INCHES INCHES
�e f Zcjsf- 3�Y ��y7« zrl .o �o.� aLi
_ 2
�2 C !tit¢�c, a�4'73 4!JD 3iy (.(1!0 3/y 66 ,f& f7.O ZLI Z �- •— ,33
i hec-v► -�rti, aFs b� Z�l�! ! 1 l� R- zi 37
DOM �k iti tz 1"7,77 Z 7 3 Z �
N
Community Development Office ;
own of Queensbury • 742 Bay Road - Queensbury, New York -12804 ;
Marilyn Ryba, Executive Director■ David Hatin, Director of Building&Codes
Craig Brown,Zoning Administrator ; 01
�.____.__r______________.
BUILDING PERMIT CALCULATION SHEET:
NATURAL LIGHT, VENTILATION AND EMERGENCY EGRESS REQUIREMENTS
HT REQUIRED ACTUAL SQUARE FOOT
HABITABLE ROOM AREA OF ROOM IN ACTUAL FOOTAGE VENTILATION-4% VENTILATION OPENING FOR REMARKS
SQUARE FEET SQUARE FOOOTA OF ROOM AREA SQUARE FOOTAGE EGRESS
Door
a-7 sF ,ay L,, t -7 .-765 775
QUESTIONS? CALL 761-8256 OR EMAIL
codes(@gueensburV.net
1 VISIT OUR WEBSITE FOR MORE INFORMATION
www.guensburV.net
h Cotimimnity Developfzient Office E E I E
Town of Queensbury• 742 Bay Road • Queensbury, New York •12804
Marilyn Ryba,Executive Director•David Hatin, Director of Building&Codes NOV 3 0 2005
Craig Brown,Zoning Administrator
TOWN OF QUEENSBURY
PRINCIPAL STRUCTURE: BUILDING AND CODE
HOW TO SUBMIT AN APPLICATION FOR ZONING APPROVAL &BUILDING PERMIT
Please include the following documentation with the submission of a completed APPLICATION FOR BUILDING&
ZONING PERMIT:
1. TWO PLOT PLANS—Drawn to scale with the use of a survey map if possible
■ Indicate proposed structure, showing setback dimensions from all surveyed property lines
■ Show location of all existing structures on the property
■ Show location of water supply(well or water lines)
■ Show location and configuration of septic disposal system or sewer line
2. TWO SETS OF STRUCTURAL DRAWINGS—to include:
■ Floor Plan
■ Foundation Plan
■ Cross Sections
■ Elevations
■ Window and Door Schedule
■ Building Permit Calculation Sheet for Natural Light,Ventilation & Emergency Egress
----------------------------_--------------------------------___________-_______,
i NOTE: Applications for COMMERCIAL STRUCTURES must include design loads for the following: ;
FLOOR■ SNOW LOAD■WIND LOAD ■ SEISMIC DESIGN ;
fREOU':REC)AF ER!ANUAW 1,2003) i
3. REGISTERED ARCHITECT OR ENGINEERS STAMP (signed&sealed)under the following circumstances:
■ Residential addition with construction costs over$20,000
■ Single-family dwelling 1,500 sq.ft. or greater
■ Any commercial construction
A! TWO COPIES OF THE NEW YORK STATE ENERGY CONSERVATION CONSTRUCTION CODE
(signed&stamped) Contact:www.energycodes.gov for a downloadable version of these programs and
compliance documents
5. FIREPLACE AMOR WOODSTOVE SOLID FUEL BURNING APPLICATION
6. SEPTIC DISPOSAL PERMIT APPLICATION
QUESTIONS? CALL 761-8266 OR EMAIL
7� ELECTRICAL INSPECTION AGENCY codes(ftueensburv.net
��l/// . (certified by the Town of Queensbury) VISIT OUR WEBSITE FOR MORE INFORMATION
8. DRIVEWAY PERMIT (if applicable) www.ciuensburv.net
All Applications are subject to Zoning Administrator, Code Compliance, and Structural plan review. Approval of your
application could be subject to a variety of reviews, including but not limited to:
Zoning Board of Appeals: Area, Use or Sign Variance application
Planning Board: Site Plan Review, Subdivision Review
Town Board: Septic Variance review by the Town Board of Health.
---------------------- ------------------- _-_--- r___-.-.____-._----
% iICE USE ONLY �' RECE� p
TAX MAP
NO. 0 , PERMIT NO. i 9
FEES: PER I CREATION ENGINEERING i
NOV 3 0� 2005
(If applicable) ;
----------___ _________________________ --- -____c TC)VVMOFQUHNSBUR '
BUILDING AND CODE
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER: LAICI LVD CaV(J OWNER: -s tv"(5 (�{
ADDRESS: `Z� j jgt L(me C4 - ADDRESS: It' f�►N2.��s��
PHONE NOS. SIC- 1C�S's`►�(7 PHONES NOS._
CONTACT PERSON FOR BUILDING &CODES COMPLIANCE:. L If Getz PHONE: f)-'3r Q
LOCATION OF PROPERTY: t 9 iA,iFLr,,S�
SUBDIVISION NAME:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT z
APPLY TO YOUR O ui o U-
PROJECT p ¢ O O � " w
O O M:
W J LL 2 O�Z
z Q Q �fn N° OLL d2d1
SINGLE FAMILY 7 331- 15
S� 1 C"
W . f
TWO-FAMILY
MULTI-FAMILY(NO.�
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3)
OTHER
s - Town of Queensbui�y • Community Development Office • 742 Bay Road, Queensbury, INY 12804
IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS:
ESTIMATED CONSTRUCTION COST: �, Ll LG ,0" Please complete a separate Application
for"Fuel Burning Appliances&Chimneys'
HOW MANY FIREPLACE(S) C7 AND/OR WOODSTOVES(S): available in our office
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? 4V
IS THIS A HISTORIC SITE?_ &D
PROPOSED USE OF BUILDING OR ADDITION: /-A Mf
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? 11/11)
ARE THERE EASEMENTS ON PROPERTY? 90
I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I
certify that the application, plans, and supporting materials are a true and complete
statement/description of the work proposed, that all work will be performed in accordance with the
NY State Building Codes, local building laws and ordinances, and in conformance with local zoning
regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain
a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by
a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of
occupancy.
I have read and agree to the above.
SignedA---�ck_
Director of Building & Codes: 761-8256 (for questions QUESTIONS 7 CALL 761-8256 OR EMAIL
regarding Building Permits, construction codes or septic codesp_queensbury.net
systems) (:
VISIT OUR WEBSITE FOR MORE INFORMATION
Zoning Administrator: 761-8218 (for questions regarding wWw.gueensburv.net
required permits, the permit process, application requirements or to
schedule an appointment)
This application/ proposed action described Permission is hereby granted to the above
herein is found to be in accordance with the Applicant to erect or alter the building described
zoning Laws of the Town of Queensbury. herein in accorda with said Application:
� 0
ZONING APPROVAL DATE ; BUI I &CODE A PROVAL DA E ;
, � ,
, 0
0
. Town.of Qrteensbtanf • Community Development Office • 742 Bay Road, Queensbiwij, NY 12804
06
Queens uiy Building & Code Enforcement -WRdsidtiinal Inspection
Office No. (518)761-8256 Arrive: C : �rjarr nDate Inspection request received: Inspector s Inrti
NAME: i ew IT M
LOCATION: ATE:
TYPE OF STRUCTURE:
Comments
Yes No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
or
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s . ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum%z"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/5ewer Dept.Ins ectidn Sticker
Site Plan /Variance re wire
Flood Plain Certifrcat' n, if rehgired
Okay to issue C/C C/D Temporarj/Permane ]
L:\Building&Code ms\Building Codes 'ection Forms\Residential Final Inspection Form revised 100405.doe
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection reque re d: s� ({
Queensbury Building& Code Enforcement Arrive: pn art: ; a
742 Bay Road, Queensbury,NY 12804 Inspector's Initia
NAME: H u,k S PERMIT #: D
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1,R-2, R-3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/ Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 % inch min. Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
Cooper Commercial
Cooper, CPVC,Pex One and Two-Family
nsulation/Residential Check/Commercial Check
-Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
L:\SueHemingway\$uilding.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection re ecei —�
Queensbury Building&Code Enforcement Arrive: pm e rt:
742 Bay Road,Queensbury,NY 12804 Inspector's Initia s• f✓
NAME: PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
"Y" ZN N/A
01 V") COMMENTS
Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging /
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate y�`
1 %z w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall e
Fire separation 1, 2,3 hour
ire wall 2, 3,4 hour
Firestopping
Pene a ion sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side ''/z inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC�:
Main Office 176 Doe Run Road-Manheim,PA 17545 "C� �+
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL —'
Permit No.........................................Cert. N 2 94195 Cut-in Card No.....................................
Owner..........A./!... .................��................................................_....s............... ..
Location. .....,h? � �� ... !e:.................. ..........
..c........,.......... ...............................................................
Installation Consisting of....� .........c ..�.. 1...... ..............
....................................................................................................................................................................................
....................................................................................................................................................................................
Installed By...... .`1f.. KY'2i -6" i�-P Lic.No.......................................................................................................................
The conditions following governed the issuance of this certificate,and any certificate previously issued is
cancelled:-
This certificate only covers the electrical equipment and installation conditions as of date. Upon the
introduction of additional equipment or alterations,application shall be promptly made for inspection.
Inspectors of this Company shall have the privilege of making)JR&Mclions at any time, and if its
rules are violated,the Company shall have the right
.. .. if ate.
....................Date... .` �. .................... INSPECTOR..... ....................................................
Mn..h -M R P A TAVT
70C'sbvy 6- - 2 -7 - ,D6-,
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection req est r eiv d: _
Queensbury Building&Code Enforcement Arrive: pm Depart: a t m
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials.
NAME: &ok S�� �c,�S ERMIT#: y� l
LOCATION: ti INSPECT ON: — 7
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour..
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior '
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Z- Q LD1 )ES DA Y 6 2 l -D 6
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection�uest received:
Queensbury Building&Code Enforcement Arrive.' , . a epart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:�)-�
NAME: PERMIT#: 0
LOCATION: 4-1 INSPECT ON: C, —2
TYPE OF STRUCTURE:
Y N N/A COMMENTS
+�_Framing �y
ttic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/z(w) 16 gauge 8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Y4
VC,- t �
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Ins ionrequest received: �j " �S�
Queensbury Building&Code Enforcement Arrive:)am/ , ee rt: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials,
NAME: e' PERMIT#: _ ?2—
LOCATION: INSPECT ON: -v
TYPE OF STRUC
Framing Y N N/A COMMENTS
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 Yz(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side ''/z inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
--Y�►--1
Foundation Inspection Report
Office No. (518)761-8256 Date Inspe trio ,equest r eived:
Queensbury Building&Code Enforcement Arrive: Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector' itials.
NAME: C(Jw�S4AS PERMIT#: I
LOCATION: INSPECT ON: Lr
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
ou �ton Damp mg y t
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil pof for wet areas under slab
I3acl�ll�Ap royal -��>
~} Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
dC) fKaN G ,,Y - 0C,
Foundation Inspection Report
Office No.(518)761-8256 Date In ection est received:
Queensbury Building&Code Enforcement Arrive r e, am/p Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials.
NAME: PERMIT#: �5�-- z
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Monolithic Slab
Reinforcement in Place-�? �
The contractor is responsi Vefor
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
� oaupdtio�it/;Wallpour
Reinforcement in I lace
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
1'
4f
I
•' i
f
I.
�_RevjsloncForStevens Addition I
+Pee m t#.05-921 ,__
Date Of_Revision;_6/28/06;
Reason.For-Revision:Treated Deck:
1 T-5 1/2" hI
1
8'-8 3/4" 8'-8 3/4"
Line Of 10'X 12'Treated Deck� ——————————
--
I A
Center Of Dbl.2 x 8 Girder Beam
(Beam Bolted To 4 x 4 Treated Posts —————————
Over Concrete Footings As Shown On 4'-9 7/8 4'-9 7/8"
Foundation Drawing) I L17'-5 1/2"Pr-Engineered
Scissor Trusses Over
Deck Framing: I B
2 X 8 Treated Joists 16"O.C.
Treated Decking I f
Using Existing 2 x 4 Treated Rails
With 4 X 4 Treated Posts I 6-4 1/8 New Addition I
2 X 2 Treated Ballusters I 279.33 SF 6-9 3/4" 16'
Rail Ht.To be 36"Finished Min.Above Decking
Treated Stairs W/Handrails On Both Sides II
I
B
3 2x10 HDR.Over
Posted To Foundation
T-6 1/2"CE b.
f r
i
Install New 5''Pocket Door
3-1 3/4"X 11I 7/8"MLB HDr.
Ia W/Blocking to Foundation
c I`
� 111
,
fRevisions For S ev�Addition
;P� erir F#05:921,,:
t DateOf-Rev_ision._fi/28/06 ?
L Reason FowRevision:Jreated Deck f
h t
10' 1 T-5 1/2"
4'-6" '; 4'-6"
Line of 10'X 12'Treated Deck
1 �.
+ d
I ----------=------�
I r---
2 X 12 Floor Joists Over @ 16"O.C.
16"X 16"Concrete Footings I I I W/Ledger Board Nailed And�lagged I I
4' Below Grade Min. (TYP) I I I To Existing Box Board Every 4-
W/4 X 4 Treated Posts Over I I I I I I
I I I New Foundation (1T-5 1/2" IX 16')
4 X 4 Treated Post To Foundation I I 8"Poured Concrete Walls I I
Over 16"X 12"Reinforced Footings
4"Slab Poured For Floor i I 16'
Min. Ht.3'Down From T. O.W.
I i I I Provide Access From I I
I I I Existing Basement f I I
Anchor Bolts 1'From Comes
&Every 4'Continuous I
I
i I I
I
pry
49
11.rw L
li r,
& CODE DE
ov, ,may
e �,L -�'�� • �r .. `.� it ®� s
fl
i
Oil
s'?lication
APR 2
1993
.�- ,��`"�.{.� .•'•��, � � � �g��l 1. Zo. •� �� i 9� `y
i ;• Zoning Lm iistrator
ENSBURY
Li
s , ► or •� '
�'' pop
�.-,`�'C'7t�i.x_lr,:"T4.".�1.�^:1 �.5';••',ty� I 1 �
it ber
REScheek Compliance Certificate Checked B.,—ate
2000 IECC
REScheckSoftware Version 3.6 Release 1
Data filename: C:\Program Files\Check\REScheck\STEVEN'S ADDITION.rc
(i
PROJECT TITLE: STEVEN'S ADDITION
CITY: Glens Falls
STATE:New York
HDD: 7635
CONSTRUCTION TYPE: Single Family
WINDOW/WALL RAT10: 0.23
DATE: 12/27/05
DATE OF PLANS: 11/17/05
PROJECT DESCRIPTION:
STEVENS ADDITION
11 AMETHYST DRIVE
QUEENSBURY,NY 12804
DE SIGNER/C ONTRACTOR:
OAKWOOD CONSTRUCTION-JOEL FITZGERALD
25 WAYNE COURT
QUEENSBURY,NY 12804
COMPLIANCE:Passes
Maximum UA= 101
Your Home UA=98
3.0%Better Than Code(UA)
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1:Flat Ceiling or Scissor Truss 272 30.0 0.0. 10
Wall 1:Wood Frame, 16" o.c. 532 19.0 0.0 23
Window 1:
Metal Frame with Thermal Break:Double Pane with Low-E 125 0.330 41
Door 1: Solid 18 0.370 7
Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 279 19.0 0.0 13
Crawl 1: Solid Concrete or Masonry 46 11.0 0.0 4
Wall height: 3.5'
Depth below grade: 3.0'
Insulation depth: 3.0'
Furnace 1: Forced Hot Air,90 AFUE
s
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications,and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2000 IECC requirements in RES checkVersion 3.6 Release 1 (formerly MECchec� and to comply with the
mandatory requirements listed in the RES checkInspection Checklist.
ildcr 11; 7,4azxglDate — -G�o
REScheck Inspection Checklist
2000 IECC
REScheckSoftware Version 3.6 Release 1
DATE: 12/27/05
PROJECT TITLE: STEVEN'S ADDITION
Bldg.
Dept.
Use
Ceilings: .
[ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss,R-30.0 cavity insulation
Comments:
Above-Grade Walls:
[ ] 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1:Metal Frame with Thermal Break:Double Pane with Low-E,U-factor: 0.330
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? [ ] Yes[ ]No
Comments:
Doors:
[ ] 1. Door 1: Solid,U-factor: 0.370
Comments:
Floors:
[ ] 1. Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-19.0 cavity insulation
Comments:
Crawl Space Walls:
[ ] 1. Crawl 1: Solid Concrete or Masonry,3.5'ht/3.0'bg/3.0'insul,
R-11.0 cavity insulation
Comments:
Applies to walls of unventilated crawl spaces.
Heating and Cooling Equipment:
[ ] 1. Furnace 1:Forced Hot Air,90 AFUE or higher
Make and Model Number
Air Leakage:
[ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be 1)Type IC rated,or 2) installed inside an appropriate air-tight assembly
with a 0.5" clearance from combustible materials. If non-IC rated, the fixture must be installed with a
3"clearance from insulation.
Vapor Retarder:
[ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
[ ] Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives),
mastic-plus-embedded-fabric,or tapes. Tapes and mastics must be rated UL 181A or UL 18113.
Exception:Continuously welded and locking-type longitudinal joints and seams on ducts
operating at less than 2 in.w.g. (500 Pa).
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVACPipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2"Runouts 1" and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD (Building Department Use Only)