ResCheck ,
• Generated by REScheck-Web Software
Compliance Certificate
Project New Residence
• Energy Code: 2018 IECC FILE COPY
• Locatiorl: Glens Falls, New York
Constrdction Type: Single-family
Project Type: New Construction
Conditioned Floor Area: 2,204 ft2 REVIEWED FOR
Glazing Area 11%
ENERGY COpE COMPLIANCE
Climate Zone: 6 (7635 HDD)
• Permit Date:
Permit Number:
Construction Site: owner/Agent: Designer/Contractor
10 Westberry Way Adam Taylor Jen Lockhart Ethan P.Hall
Queensbury; NY 12804 Queensbury, NY 12804 Rucinski Hall ArchitectUre
•jenlockhart09@yahoo.com 134 Dix Ave
Glens Falls, NY 12801
ephall@nycap.rr.com
Compliance: Passes using UA trade-off
Compliance: 2:8%Better Than Code Maximum UA: 325 Your UA: 316 '
The%Better or Worse Than Code index reflects how close to compliance the house Is based on code trade-off-rules.
It DOES NOT provide an estimate of energy use or cost relative to a Minimum-code home.
Envelope:Assemblies
Gross Area
Cavity Cont.
Assembly or U-Factor UA
R-Value R-Value
Perimeter
Ceiling 1: Raised or Energy Truss 2,204 38.0 0.0 0.025 55
Wall 1:Wood Frame, 16"o.c. 2,167 21.0 3.6 0.046 86
Door 1:Solid 38 0.300 11
Door 2:Solid 18 0.300 5
Door 3:Stglid 18 0.300 5
Door 4:Glass 40 0.320 13
Window 1:Wood Frame:Double Pane with Low-E 189 0.290 55
Floor 1:All-Wood JoistfTruss:Over Unconditioned Space 20 30.0 0.0 0.033 1
Basement Wall 1: Solid Concrete or Masonry 1,853 19:0 0.0 0.046 85
Wall height:8.9'
Depth below grade: 7.5' ...„ ......_..._....._. _ . —___.
Insulation depth:8.5' :.,:i. (-17' 'k=,;; il %All
' - ' '4
rA) 1::: ‘.....i I::: 0 n:\
1.) - •
..i. 1
1 I
,v,,,, 1
L ii I j j L 0 1 LiS23 ] j
TOWN 0 F Q U E E N S F:.!LY
BUILDING &COF.; 'S
---
Project Title: New Residence Report date: 07/06/20
Data filename: Page 1 of10
Compliance Statement The proposed building design described here is consistegwith the building plans,specifications,and other
calculations submitted with the permit application.The proposed building hasbeen;desgned to meet the 2018 IECC requirements in
REScheck Version :'REScheck-Web and to comply with the mandatory"r i ement te. - e-REScheck Inspection Checklist.
`` 'I
N11. . Nr— l`�'�7s r 1 rg ate
��PIU"Idea,
Name-Title Sigpat• ei_ i;C,' �� at
e y
els
Project Title: New Residence Report date: 07/06/20
Data filename: Page 2 of10
gREScheck Software Version : REScheck-Web
Inspection Checklist
Energy Code: 2018 IECC
Requirements 0.0% were addressed directly in the REScheck software
Text in the "Comments/AssUmptions" column is provided by the user in the REScheck Requirements screen. For each
requirement the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided.
Section
Plans Verified Field Verified
# Pre-Inspection/Plan Review Complies? Comments/Assumptions
Value : Value
& Recj.ID
103.1, ;ConstrUction drawings and ; Complies
,
1n2 documentation demonstrate i Does Not
[PR1]1 ;energy code compliance for the
- , • • '
building envelope,Thermal 1ONot Observable
...., , i
envelope represented on : l:INot Applicable
construction documents.
103.1, ;Construction drawings arid Momplies
103.2, idocumentation demonstrate ,1=1Does Not
403.7 ;energy code compliance for
t Obbl
[PR3]1 :lighting and mechanical systems. IONo serva e
Systems serving Multiple • IONot Applicable
;dwelling units must demonstrate. 1
1
compliance with the IECC ,
i commercial Provisions.
302.1, IHeating and cooling equipment is Heating: Heating Eompiies
1
403.7 I sized per ACCA Manual S based 'Biii/hr Btu/hr EIDOes Not
[PR2]2 On loads calculated per ACCA
cooling: Cooling: alot Observable
0 I Manual J or other rnethods
i
!approved by the code official. Btu/hr Btu/hr- ONot Applicable
Additional Comments/Assumptionsi
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: New Residence Report date: 07/06/20
Data filename: Page 3 Of10
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies?- Comments/Assumptions
& Req.ID
402.1.1 ,Conditioned basement wall : R R- ❑Complies See the Envelope Assemblies
[F04]1 iinsulation R-value:Where interior R. R- ❑Does Not table for values.
' :insulation is used;verification
may need to occur during ['Not Observable
Insulation Inspection: Not ❑Not Applicable
:required in warm-humid locations
i in Climate Zone 3.
303.2 ;Conditioned basement wall ❑Complies.
[F05]1 iinsulation installed per : 1 }❑Does Not
44, . :manufacturer's:instructions.
10Not.Observable
I❑Not Applicable:.
402.2.9 . :Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[F06]1 iinsulation depth of burial or DDoes Not table for values.
U distance from top of wall.
❑Not Observable
❑Not Applicable
303.2.1 1A protective covering is installed 1❑Complies
[F011]2 ito protect exposed exterior I❑Does Not
,J insulation and extends a.
DNot Observable
minimum of 6 in. below grade.
❑Not Applicable.
403.9 'Snow-'and ice-melting system. 1❑Complies
[F012]2 controls installed. i❑Does Not
J I I❑Not Observable
• I❑Not Applicable . .
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) . 3 Low Impact(Tier 3)
Project Title: New Residence Report date: 07/06/20
Data filename: Page 4 of10
Section Plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, 1 Door U-factor. U U ❑Complies See the Envelope:Assemblies
402.3.4 ❑Does Not table for values.
[FRl]1
�� ❑Not Observable
❑Not Applicable
402.1.1; ;Glazing U-factor(area-weighted U- U- ;❑Complies See the Envelope Assemblies
402.3.1, ;average). ;❑ge) Does Not
table for values.
. N
402.3.3,
402.5 ;❑Not Observable
[FR2]1 I ;❑Not Applicable
303.1.3 ;U-factors of fenestration products IDComplies.
.
[FR4]1 fare determined in accordance 10Does Not .
;with the NFRC test procedure or
4 :taken from the default table. !❑Not Observable
i 1❑Not Applicable
402.4.1.1 ;Air barrier and thermal barrier IEIComplies
[FR23]1 installed per manufacturers I i❑Does Not
;A instructions.. ; ;DNot Observable
ffi ;❑Not Applicable
402.4.3 Fenestration that is not site built I❑Complies
[FR20]1 i is listed.and labeled as meeting. ( ❑Does Not
IAAMA/WDMA/CSA 101/I.5.2/A440
4for has infiltration rates per NFRC I Not Observable
400 that do not exceed code i ONot Applicable
limits.
402.4.5 I IC-rated recessed lighting fixtures ❑Complies
[FR16]2 Isealed at housing/interior finish Oboes Not
land labeled to indicate 5_2.0 cfm
;leakage.at 75 Pa. ❑Not Observable
:Dot Applicable
403.3.1 :Supply and return ducts in attics { j❑Complies
[FR12]1 'insulated >= Ft-8 where duct is i 10Does Not
;>=3 inches in diameter and > - -
R-6 where< 3 inches.Supply and i 1❑Not Observable
;return ducts in other portions of 11=INot Applicable
;the building insulated >= R-6 for ; }
;diameter>= 3 inches and R4.2 ,
for'<3 inches in diameter.
403.3.2 Ducts,air handlers and filter - ❑Complies
[FR13]i ;boxes are sealed with ; ❑Does Not
;®J ' :joints/seams compliant with
International Mechanical Code or 10Not.Observable
International Residential Code,as{ IDNot Applicable
;applicable. i 1 .
403.3.5 I Building cavities are not used as lEIComplies
[FR15]3 ;ducts or plenums. IODoes Not
8' 1
❑Not Observable
1 ;❑Not Applicable
I 1 1 High Impact(Tier 1) Medium Impact(Tier.2) 3 Low Impact(Tier 3)
Project Title: New Residence Report date: 07/06/20
Data filename: Page 5 of10
Section. Plans Verified Field Verified .
# Framing/Rough-In Inspection Complies? Comments/Assumptions
&Req.ID Value Value
403.3.7 Ducts declared to be within the (❑Complies
[FR28]3 conditioned space are either 1) ! 1❑Does Not
„9, Icompletely within the continuous
air barrier and within the building i !❑Not Observable
thermal envelope, 2)buried i❑Not Applicable
within ceiling insulation in
iaccordance with Section i
!R403.3.6 and the air handler is I !
I located completely within the
Icontinuous air barrier and within € _
;the building thermal envelope
land the duct leakage is<_ 1.5
cfm:/100 square feet of
conditioned floor area served by
!the duct system,or 3)the ceiling
insulation R-value installed
against and.àbove the insulated
`duct>=to the proposed ceiling
Iinsulation.R-value, less.the R-
value of the insulation on the
403.4 HVAC piping conveying fluids R- R- ;❑Complies
[FR17]2 o;above 105-F or chilled fluids I❑Does Not
J ;below 55 4F are insulated to>R- I_
3 ;❑Not Observable
❑Not Applicable
403.4.1 Protection of insulation on HVAC ; ❑Complies
[FR24]1 ;piping. i ❑Does Not
e, I I ❑Not Observable
I., ❑Not Applicable
403.5.3 j Hot water pipes are insulated to R- R- ❑Complies
[FR18]2 ;>_R-3. ❑Does Not
U i ❑Not Observable
i ONot Applicable
403.6 ;Automaticor gravity dampers are - ;❑Complies
[FR19]2 'installed on all outdoor air ❑Does Not
;intakes and exhausts.
11:1Not Observable
i S j❑Not Applicable
Additional Comments/Assumptions:
� Impact(Tier 3)
l 1 1 High Impact(Tier 1) 1 2 Mediumimpact(Tier 2) 3 Low
Project Title: New Residence Report date: 07/06/20
Data filename: Page 6 of10
Section. Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 All installed insulation is labeled l❑Complies
[IN13]z or the installed R-values 1❑Does Not
;provided.
I❑Not Observable
❑Not Applicable
402.1.1, ;Floor insulation R-value: R- R: ❑Complies See the Envelope Assemblies
402.2.6 table for values.
[imp ❑ Wood � Wood Oboes Not
❑ Steel ❑ Steel ;]Not Observable
❑Not Applicable
303.2, Floor insulation installed per 1 ❑Complies
402.2.7 manufacturer's instructions and ❑Does Not. .
[IN2]1 in substantial contact with the
gip' . ;underside pf the subfloor,or floor; ;❑Not.Observable
framing cavity insulation is in IONot Applicable
contact with the top side of
;sheathing,or continuous
'insulation is installed on the
underside of floor framing and
extends.from the bottom to the
;top of all perimeter floor framing
members: ;
402.1.1, ;Wall insulation R-value. If this is a R- R .. ❑Complies See the Envelope Assemblies
402.2.5, ;mass wall with at least V2 of the ❑ Wood ❑ Wood Oboes Not table for values.
402.2.6 ;wall insulation on the wall ❑ Mass ❑ Mass
[IN3j1 ;exterior,the exterior insulation ❑Not Observable
Steel requirement applies(FR10). ❑ El Steel ONot Applicable
303.2 'Wall insulation is installed per ;❑Complies
[IN4]1 !manufacturer's instructions. ;ODoes Not
IQNot Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: New Residence Report date: 07/06/20
Data filename: Page 7 of10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Ceiling insulation R-value. R- R- DComplies See the Envelope Assemblies
402.2.1, ❑ Wood 0 Wood DDoes Not table for values.
402.2.2, ❑ Steel 0 Steel ONot Observable
402.2.6
[FI1]1 ❑Not Applicable
303.1.1.1,;Ceiling insulation installed per ;DComplies
303.2 :manufacturer's instructions. 1❑Does Not
[FI2ji ;Blown insulation marked every i
300 ft2. lENot Observable
;❑Not Applicable
402.2.3 ;Vented attics with air permeable i .. ;❑Complies
(FI22)2 !insulation include baffle adjacent ;❑Does Not
;to soffit and eave vents that
,extends over insulation.
❑Not Observable
i ! ;❑Not Applicable
402.2.4 ;Attic access hatch and door R- R- DComplies
[F13]1 insulation >_R=value of the Oboes Not
;adjacent assembly.
[Mot Observable
. ONot Applicable
402.4.1.2 ;Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50=. DComplies
[F117]1 ;achin Climate Zones 1-2,and ❑Does Not
<=3 ach in Climate Zones 3-8. ONot Observable
❑Not Applicable
403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[F127]l. determine air leakage with ft2 ft2 Oboes Not
;either: Rough-in test:Total
;leakage measured with a ONot Observable
pressure differential of 0:1 inch ONot Applicable
;w,g.across the system including
:the manufacturer's air handler
!enclosure if installed at time of
;test. Postconstruction test:Total
leakage measured with a
j pressure differential of 0.1 inch
w.g.across the entire system
:including the manufacturer's air
handler enclosure.
403.3.4 DUct tightness test result of<=4 cfm7100 cfm/100 DComplies
[FI4]1 i cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
;<=3 cfm/100 ft2 without air ONot Observable
:handler @ 25 Pa. For rough-in
tests,verification may need to DNot Applicable
occur during Framing Inspection.
403.3.2.1 ;Air handler leakage designated 'DComplies
[FI24]1 :by manufacturer at<=2%of Oboes Not
;design airflow. + :.
❑Not Observable
❑Not Applicable
403.1.1 ;Programmable thermostats !DComplies
[Fl9]2 :installed for control of primary i0Does Not
heating and cooling systems and
initially set by manufacturer to ONot Observable
i code specifications. . i ONot Applicable
403.1.2 !Heat pump thermostat installed ;DComplies
[FI10]2 on heat pumps. i !❑Does Not
, ,ONot Observable
❑Not Applicable
403.5.1 ;Circulating service hot water ; ❑Complies
[FI11]2 :systems have automatic or i ;❑Does Not
accessible manual controls. l ,
1❑Not Observable
ONot Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: New Residence Report date: 07/06/20
Data filename: Page 8 of10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID .
403.6.1 :All mechanical ventilation system ;❑Complies
[F125]2 fans not part of tested and listed ; i❑Does Not
HVAC equipment meet efficacy
and air flow limits per Table ❑Not Observable
R403.6.1. ;❑Not Applicable
403.2 ;Hot water boilers supplying heat ❑Complies
[F126]2 ;through one-or two-pipe heating ❑Does Not
systems have outdoor setback
i control to lower boiler water ❑Not Observable
temperature based on outdoor ❑Not Applicable
;temperature.
403.5.1.1 ;Heated water circulation systems ; ;❑Complies
[F128]2 !have a circulation pump.The !DDoes Not
;system return pipe is a dedicated
return pipe or a cold water supply l ❑Not Observable
!pipe.Gravity and thermos- :❑Not Applicable
;syphon circulation systems are
not present. Controls for i
circulating hot water system '
pumps start the pump with signal
for hot water demand within the
;occupancy.Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and ; •
no demand for hot water exists. 1
403.5.1.2 ;Electric heat trace systems ; ',❑Complies
[F129]2 comply with IEEE 515.1 or UL iODoes Not
515.Controls automatically i
adjust the energy input to the ,❑Not Observable
heat tracing to maintain the `DNot Applicable
•
desired water temperature in the
piping.
403.5.2 i Demand recirculation water ; ;❑Complies
[F130]2 !systems have controls that 10Does Not
;manage operation of the pump
:and limit the temperature of the ❑Not Observable
;water entering the cold water !❑Not Applicable
;piping to <= 104°F.
403.5.4 :Drain water heat recovery units {❑Complies
[FI31]2 ;tested in accordance with CSA iODoes Not
B55.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
'recovery units < 3 psi for 11=INot Applicable
individual units connected to one ;
;or two showers. Potable Water-
;side pressure loss of drain water
;heat recovery units< 2 psi for
individual units connected to
;three or more showers. .
404.1 90%or more of permanent '❑Complies
[Fl6]1 ;fixtures have high efficacy lamps. ;❑Does Not
❑Not Observable
❑Not Applicable
404.1.1 I Fuel gas lighting systems have i❑Complies
[FI23]3 ;no continuous pilot light. i0Does Not
V' ! ;❑Not Observable
i ❑Not Applicable
401.3 :Compliance certificate posted. ❑Complies
[FI7]2 ; i❑Does Not
❑Not Observable
;❑Not Applicable ;
ET. High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: New Residence Report date: 0.7/06/20
Data filename: Page 9 of10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
303.3 i Manufacturer manuals for ;❑Complies
[FI18]3 I mechanical and water heating i❑Does Not
systems have been provided.
❑Not Observable
;❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: New Residence Report date: 07/06/20
Data filename: Page 10 of10
CI2018 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
Above-Grade Wall 24.60
Below-Grade Wall 19.00
Floor 30.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Glass& Door Rating U-Factor SHGC
Window 0.29
Door 0.32
Heating&Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments