Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2005-956
TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20050956 Date Issued: Monday, October 15, 2007 This is to certify that work requested to be done as shown by Permit Number P20050956 has been completed. Location: 9 HERESFORD Ln Tax Map Number. 523400-308-008-0002-075-000-0000 p Owner. RICHARD & THERESA LAWSON Applicant: RICHARD & THERESA LAWSON This structure maybe occupied as a: Garage Attached By Order of Town Board Residential Addition To OF QUE�VS URY Residential Alteration Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. i TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 I Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: :p20050956 Application Number: A20050956 Tax Map No: 523400-308-008-0002-075-000-0000 Permission is hereby granted to: RTCHARD & THF,RFSA T;AWSON For property located at: 9 HERESFORD Ln in the Town of Queensbury,to constructor place ' at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value J Owner Address: RICHARD & THERESA LAWSON 9 HERESF ORD Ln Garage Attached Residential Addition $41:000.00 QUEENSBURY;NY 12804 Residential Alteration Total Value $41,000.00 i is Contractor or Builder's Name /Address ! Electrical.Inspection Agency PATRTCK BURKE CONSTRUCTION 936 BAY Rd OTTEENSBITRY_ NY 12864-0000 Plans&Specifications 2005-956 240 SQ FT RESIDENTIAL'ALTERATION ( CONVERT GARAGE INTO LIVING SPACE, 500 SQ FT ADDITION ABOVE AND 240 SQ FT ATTACHED GARAGE sandyk- 12/29/2005 10:56:33 AM i $145.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Thursday, January 18, 2007 (If a longer period is required,an application for an extension must ue made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) f Dated at the To7,n-o1 Queensbury; a esday,January 18, 2006 SIGNED BY :. for the To«m of Queensbury. Director of Building C 0de nforcement FYCbeek Residential Plan Review: One�&Two Family Dwellings IN/ /A (2)Full sets of plans Over 1,500 sq. 11.—Stamped Design Loads On Plans: 90 Wind < Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade, 5.7 sq.ft. Grade,5.0 sq.ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofmg/Waterproofing Materials On Plans tI Foundation Drainage On Plans,if required 6"Drop in 10'Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where Required Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise Winder Run and Rise Spiral Not Allowed From 2 Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width,V'min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation age Floor Sloped ttic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level I Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed ----------------------- Communi Develo ment O i� ce , own of Queensbury ■ 742 Bay Road • Queensbury, New York •12804 ; Marilyn Ryba, Executive Director• David Hatin, Director of Building&Codes 0 ; Craig Brown,Zoning Administrator ; 1 , , , WINDOW SCHEDULE ' JOB SITE/ADDRESS: H e/e DATE: OWNER: 4 t lyo t APPLICATION NO.: WINDOW- UNIT OR CLEAR CLEAR WINDOW STOCK ROUGH ROUGH SQ.FT. OPENING NO.OR WINDOW SQ.FT. OPENING SPECIAL HARDWARE OR MANUFACTURER NUMBER OPENING OPENING EGRESS/CLEAR WIDTH IN I HEIGHT INSTRUCTIONS LETTER NAME MODEL/TYPE CALL WIDTH HEIGHT VENT OPENING N ON PLAN SIZE INCHES INCHES U�(_301138 g 71Iq ,z,ci/ IS , Z 3 s/ 2 q' z Ca 01 ,�j 0(-1 ------------------------------------- OFFICE USE ONLY TAX MAP N0. — PERMIT NO. - DEC 2 8 2005 I i FEES: PERMIT / CREATION ENGINEERING i'I : _c�c7 (If applicable) _� f 111.1 _irn;':`�`Gl CO PRINCI� L 5 TR UCT URE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE lOF A VALID PERMIT FOR CONSTRUCTION. ) ) K A k l_.l�>'J dr OWNER: �+�c�,��o� 4 T)ezescs l�c%�a APPLICANT/BUILDER: !� riF r -T -� � - r► ADDRESS: ADDRESS: q Were S1L1 rpr l*n PHONE NOS. 2?2' q j,V,__) Pis--00 J q _ PHONE NOS. 7 yS-U019 CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: PHONE: LOCATION OF PROPERTY: SUBDIVISION NAME: it��e� �oe�A h`iYzneS' PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT 00 o � APPLY TO YOUR ¢ 0 U) rn l,w PROJECT ,O I— O w IL w u- C3 U F- _ o o u 2 0 _ z. Z Q Q (� N O L IL 2 00 SAYK. 0.S SINGLE FAMILY ✓ ✓ TWO-FAMILY MULTI-FAMILY P (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE �r s , RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED ✓ y� GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: 44,006 Please complete a separate Application —T— for"Fuel Burning Appliances&Chimneys" available in our office HOW MANY FIREPLACE(S): o AND/OR WOODSTOVES(S):�_ ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? yo IS THIS A HISTORIC SITE? PROPOSED USE OF BUILDING OR ADDITION: I v ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? /1/p 1, Town of Queensbury - Community Development Office • 742 Bay Road, Queensbury,NY 12804 1 ARE THERE EASEMENTS ON PROPERTY? IVQ I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. 1 have read and agree to the above. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) "�, , 0 Permission is hereby granted to the above ; This application / proposed action described Applicant to erect or alter the building ; ; herein is found to be in accordance with the 01 described herein in accordance with said o zoning Laws of the Town of Queensbury. Application: ; ; 1 , , 1 ' , , , , / / , , 0 / , 1 I l_ 01 , 01 I , , / , , 00 BIJILX(NG,& CODES AP P ZONING APPROVAL 0 0 0 / ' 0 ' ' 0 DAT 0 'o DATE QUESTIONS? CALL 761-8256 OR EMAIL codes@queensbury.net VISIT OUR WEQSITE FOR MORE INFORMATION _ www.gueensbury.net Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury,NY 12804 l�'i Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/ m Depart:,& m Date Inspection request received: Inspector's Initials: NAME: PERMIT7-5 LOCATION: �' � � DATE: " TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road p > ChimneyHeight/"B"Vent/Direct Vent Location d e� `� Fresh Air Intake �`�r/'��, 7/4," 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete V Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above ade G Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: cry e m area: nter Connected: Battery backup: etector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s . ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''/2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required ` Flood Plain Certification,if required Okay to issue C/C or C/O [Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: -S Queensbury Building& Code Enforcement Arrive: am/pm Depart: ,-� �a pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: L_ A..v s cy-, PERMIT #: LOCATION: S INSPECT ON: P 3 0(2;1 TYPE OF STRUCT --T- Y N N/A PVC: R-1,R-29 R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/ Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min. Drain Size WashingMachine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial __ Cooper, CPVC,Pex One and Two-Family nsulation/Residential Check/ Commercial CheckProper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: ��lU " � ���_ � ��-- o\`�- L:\SueHemingway\Building.Codes.inspection.FORMS\Rough Plumbing Insulation Report.doe November 17,2003 Rough Plumbing / Insulation Inspection Report Office No. (51 8) 761-8256 Date Inspection re!!ff Queensbury Building& Code Enforcement Arrive: a m 742 Bay Road, Queensbury,NY 12804 Inspector's Ini NAME: �, LOCATION: p - INSPECT ON: a1-0� TYPE OF STRUCTURE: Y N N/A � PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron, Copper Drain/Vent/ Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min. Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes x tS�L - Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial o er, CPVC,Pex One and Two-Family \ nsulation/Residential Check/ Commercial Check V. C\ Pro er Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct toe COMMENTS: xy v LASueHemingway\13uilding.Codes.Inspection.FORM S\Rough Plumbing Insulation Report.doc November 17,2003 Flo Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: 3 �� Queensbury Building&Code Enforcement Arrive: am/pm Depart:I cs d) am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: i,J Sow- NAME: -� PERMIT#. LOCATION: INSPECT ON: TYPE OF STRUCTURE: i Y; ,N N/A COMMENTS " Framing Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers _ Jack Posts/Main Beams 670tiT `' Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls j \ 1 Metal Strapping for Notches To Plate PP g P 1 `/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour �. Fire wall 2, 3,4 hour 1 _Firestopping_-- - Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Rough Plumbing / Insulation Inspection Deport Office No. (51 8) 761-8256 Date Inspection request received: 3 Queensbury Building& Code Enforcement Arrive: am/pm Depart: 'm/pm 742 Bay Road, Queensbury,N.Y 12804 Inspector's Initials: NAME: �JSv�'� PERMIT #. LOCATION: c INSPECT ON: - 3 a v C TYPE OF STRUCTURE: % Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/ Comm. Plumbin Vent/Vents in Place / ou h Plumb>< /Nail Plates 1 : inch min. Drain Size. Washing Machine Drain 2 inch min. Head or Air Supply Test _Dxainand Vents �5 PSYr 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction -- Water Supply Piping Cooper Commercial Cooper, CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart= am/p 742 Bay Road, Queensbury,NY 12804 Inspector's Initials:`/,,� ' U NAME: PERMIT#: c � 15C f LOCATION: 2 INSPECT ON: TYPE OF STRUCTURE: Y Ni N/A COMMENTS -Framing Attic Access 22"x 30"minimum Jack Studs/Headers l Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/z(w) 16 gauge(8) 16D nails each side Draft stop pi ,000 sq. ft. floor trusses Anchor olts 6 ft. or less on center r Ic and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side ''/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing/ Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: o, b, Queensbury Building&Code Enforcement Arrive: am/pm Depart: ? am/ m 742 Bay Road, Queensbury,NY 12804 Inspector's Initials NAME: � `J � V�-e— PERMIT#: p[ O� LOCATION: INSPECT ON: Z4 j TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center ce and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Rough Plumbing / Insulation Inspection Rep orb � Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart: f `0 a /pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:/t NAME: Aw 5 C- PERMIT #: 200 �✓ S LOCATION: C 5 L a-INSPECT ON: 0 TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial CheckProper Vent Attic Vent _ Duct/ Hot Water Piping Insulation �— If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&CodesUnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Foundation Inspection Report Office No. (518)761-8256 Date In ectif�n st e received: Queensbury Building&Code Enforcement Arrive: I y 5am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: I LOCATION: _ INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A otings Piers Monolithic Slab )-3 Reinforcement in Place The a- The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM 1 NE LLI W. RzECEII FESS DEC 2 8 2005 N Uj M Uj M M Ljj 2 t; _j C:) F,-- , ILI 0. M LLJ ;63 60W151j UF il "EN, OF OUEENSGURY BUILDING DERATMENT Eased on our IirnRf;';d examination �UILDING C � I comEliance with our comments shaii not e construed as indicating the REVIEWED plans and specifications are in full compliance with the Building Codes DA, TE rib S, ui of New Voll,9,tRfe- 7 14 C/1) U-) NOTICE SMOKE DETECTORS ARE REQUIRED IN BEDROOKub ADJACENT TO BEDROOMS,AND ON EACH FLOORIEVEL INCLUDING CELLAR OR BASEMENT.ALL SMOKE DETECTORS SHALL BE INTERCONNECTED ON ALL LEVELS ALL SMOKE DETECTORS MUST BE BATTERY BACKUP CARBON MONOXIDE DETECTOR REQUIRED OUTSIDE LOWEST SLEEPING LEVEL .71 6 41 �F NEWY 1 r3 co- `AOFESS10N { $ CaCAS \Y!$C:c I !*emOv c Ll 3 !$_ F_ )1 , ten. I 4 if { ..,. NE F � ON pR�FESSIO�P zin ASk, a — f 1 r 3 t i rl 1 1 S! e t"o iu L in 11 a ul O"urY.)"o \yv ;.14 L 3U Rf 4t o vAt C44'rtNo vl�Cy v %,vfa Y, 4 V6 u \NIR 7 NE lI .—F 6 CA 2,1 H A4 CO cc 3 IF 60,0 LIP, zd- ICU �jd Q ..... ...... td oky A, -),ell iV 11(A Yl t, OVt 41 41 t. � .� � y�s-.=tom � E x f � •-..F eY !4 I Lill 4 pp �,.-.'.-- •Y gip, t t a l _ t; { ilk. rn r Framing and Construction Notes: General Notes: 1. Hold framing 1/2' from outside face of 1. ALL work shall conform to appticable state foundation wall to allow for ply sheathing, and local building and energy code requirements. Construction shall be In 2. Floor ,Joists to be doubled under all accordance with New York State Uniform parallel partitions. Studs to be doubled Fire Prevent and Building Code under all headers and LVL beams. requirements. 3. Flush framed wood members shall be 2. Plumbing, Mechanical, and Electrical Design anchored w/200 lb, min. ,Joist hangers. by others. These systems and components have not been represented on these 4. Wood Grades 'Standard' Grade Light - drawings, framing size lumber of any species or 3. All Electrical work shall comply with NFPA board-size lumber as required. 'No. 3 Common' or 'Standard' grade boards per 70, National Electric Code. West Coast Lumber Inspection Bureau or Western Woods Product Association Rules 4. The Engineer not responsible for a or 'No. 2 Boards' per Southern Pine construction administration nor site Insectlon Bureau Rules, Inspections to determine compliance with these plans and specifications. Any 5. Construction Panel Standardsi Comply with construction deviations from the certified PS 1 'U.S. Product Standard for plans and specifications, not approved by Construction and Industrial Plywood' for the Engineer In writing render the Engineer plywood construction panels and for Certification null and void, products not manufactured under PS 1 5. These drawings do not Include necessary Provisions, with APA RPR-108. components for construction saftey. 6. All Interior walls are 2x4 construction. Means, methods and techniques of construction are the sole responsibility of 7. Where lumber or plywood Is Indicated as the contractor, preservative-treated wood or pressure treated, 6. It shalt be the owners responsibility to comply with applicable requirements of AWPA report, In writing, after Engineer approval, Standards C3 Qumber) and Cp (Plywood), Mark each all deviations and changes In and between treated Item with the AWPB or SPIB quality mark �pF NEt1/y the actual construction and the Engineer requirements. '` ASH Wj certified documents. Such report shall be 8. All materials shall be new and free of defects. COD delivered to the local Building Code * �'y * Enforcement Agency for review and 9. Finishes shall be coordinated between the owner and cc approval. contractor. All finishes must comply with section n W 7. The owner shall to the fullest extent 718 of the Uniform Fire Prevention and Building y permitted by law, Indemnify and hold Code. -97'%N �� harmless the Engineer, his agents and 10. Concrete shall have a minimum strength of 3000 psi. Ai9� �P employees, from and against all claims, g p FESSI� damages, losses and expenses arising as a result of any deviations, changes and/or vZ� non-conformances In and between the actual construction and the Engineer Certified Documents, 8. Unauthorized alteration of these Design Criteria: documents Is a violation of the New York State Education Law, Seismic Frost 1st 2nd 9. Builder shall maintain an & all Insurances Ground Wind y Design Line Floor Floor required b owner. Certification does not Snow Load Speed Category Depth Load Load extend to review of compliance with any 40 PSF Live 40 PSF Live local building, planning and/or zoning codes 85 lbs 90 MPH C 48' 10 PSF Dead 10 PSF Dead and regulations. Conformance to any codes referenced by this paragraph Is the sole responsibility of the Individual filing an application for a building permit. CI _______i__--____________I I I I I . QCoo:7unity Development Officef Queensbury • 742 Bay Road • Queensbury, New York ■12804 ; Marilyn Ryba,Executive Director■David Hatin,Director of Building&Codes ; Craig Brown,Zoning Administrator ------------ BUILDING PERMIT CALCULATION SHEET: NATURAL LIGHT, VENTILATION AND EMERGENCY EGRESS REQUIREMENTS AREA OF ROOM IN ACTUAL LIGHT REQUIRED ACTUAL SQUARE FOOT HABITABLE ROOM SQUARE FEET SQUARE FOOTAGE VENTILATION4% VENTILATION OPENING FOR REMARKS OF ROOM AREA SQUARE FOOTAGE EGRESS Sb 'ARI iI /cA L LI`G 1 .fgy lL 13E 6 6 1N r70�( 'to ,2o✓jh FJ/J f1✓E f3 6`."I A ,v A AI 7 LOX) c v C,Q 7"k 6 M it/9 ap 7-11,4 n 00/4 /9 r 4 14C-11661T of 36 11 /9 6611 /e C 40 F NEW H M. QUESTIONS? CALL 761-8256 OR EMAIL codes(cDgueensburv.net °C W VISIT OUR WEBSITE FOR MORE INFORMATION www.guensbury.net OFESSIO�P� '9555 U.m Double Hung Opening Specications ,,, D 0° D •' D ! D D VNC 18210 21 3/4 x 36 3/4 1.51 17 5/8 x 12 5/16 1.98 17 518 x 16 3/16 3.01 18 11/16 x 33 9/16 16 5/8 x 15 VNC 1832 21 314 x 40 3/4 1.75 17 5/8 x 14 5/16 2.23 17 5/8 x 18 3/16 3.44 1811/16 x 37 9/16 16 5/8 x 17 VNC 18310 21 314 x 48 3/4 2.24 17 518 x 18 5116 2.72 17 5/8 x 22 3/16 4.31 1811/16 x 45 9/16 16 5/8 x 21 VNC 1842 21 314 x 52 3/4 2.49 17 518 x 20 5116 2.96 17 5/8 x 24 3116 4.74 1811/16 x 49 9/16 16 518 x 23 VNC 1846 21 3(4 x 56 3/4 2.13 17 5/8 x 22 5/16 321 17 5/8 x 26 3116 5.17 1811/16 x 53 9/16 16 5/8 x 25 VNC 1852 21 3/4 x 64 314 3.22 17 5/8 x 26 5M6 3.69 17 5/8 x 30 3116 6.04 1811/16 x 61 9/16 16 5/8 x 29 VNC1856 CS 21 314 x 68 314 2.73 17 5/8 x 22 5116 4.67 17 5/8 x 38 3116 6.47 1811/16 x 65 9/16 16 5/8 x 25 TOP 16 518 x 37 BOTTOM VNC 1862 2134 x 76 3/4 3.95 17 5/8 x 32 5/16 4.43. 17 5/8 x 36 3116 T34 1811/16 x 73 9/16 16 5/8 x 35 VNC20210 25 3/4 x 36 3/4 1.85 21 518 x 12 5116 2.43 21 518 x 16 3/16 3.79 2211/16 x 33 9/16 20 5/8 x 15 VNC2032 25 314 x 40 3/4 2.15 21 5/8 x 14 5/16 2.73 21 5/8 x 18 3/16 4.33 2211/16 x 37 9/16 20 518 x 17 VNC203101 25 314 x 48 3/4 2.75 21 5/8 x 18 5116 3.33 21.5/8 x 22 3/16 5.42 2211/16 x 45 9/16 20 5/8 x 21 VNC2042 25 3/4 x 52 3/4 3.05 21 5/8 x 20 5/16 3.63 21 518 x 24 3/16 5.96 2211/16 x 49 9/16 20 5/8 x 23 VNC2046 25 3/4 x 56 3/4 3.35 21 5/8 x 22 5/16 3.93 21 5/8 x 26 3/16 6.50 2211/16 x 53 9/16 . 20 5/8 x 25 VNC2052 25 314 x 64 314 3.95 21 5/8 x 26 5116 4.53 21 518 x 30 3/16 T59 2211/16 x 61 9/16 20 5/8 x 29 VNC2056 CS 25 3/4 x 68 3/4 3.35 21 5/8 x 22 5/16 5.73 21 5/8 x 38 3/16 8.13 2211116 x 65 9/16 20 5/8 x 25 TOP 20 518 x 37 BOTTOM VNC2062 25 3/4 x 76 3/4 4.85 21 5/8 x 32 5/16 5.43 21 5/8 x 36 3116 922 2211/16 x 73 9/16 20 5/8 x 35 VNC24210 29 3/4 x 36 3/4 2.19 25 5/8 x 12 5/16 2.88 25 5/8 x 16 3/16 4.56 2611/16 x 33 9/16 24 5/8 x 15 11h: 29 f _ 24 B x 522 626 �/j16tx{37 11 .. 4j --- VNC24310 29 3/4 x 48 3/4 3.26 25 5/8 x 18 5/16 3.95 25 5/8 x 22 3/16 6.52 26 T1/16 x 45 9/16 24 5/8 x 21 VNC 2442 29 3/4 x 52 3/4 3.61 25 5/8 x 20 5/16 4.30 25 5/8 x 24 3116 7.18 2611/16 x 49 9/16 24 518 x 23 VNC2446 29 3/4 x 56 3/4 3.97 25 5/8 x 22 5/16 4.66 25 5/8 x 26 3/16 7.83 2611/16 x 53 9/16 24 5/8 x 25 VNC2452 29 314 x 64 3/4 4.68 .25 518 x 26 5116 5.37 . 25 5/8 x 30 3116 9.14 2611/16 x 61 9/16 24 5/8 x 29 VNC2456 CS 29 3/4 x 68 314 3.97 25 5/8 x 22 5116 6.80 25 5/8 x 38 3/16 9.80 2611/16 x 65 9/16' 24 5/8 x 25 TOP 24 5/8 x 37 BOTTOM VNC2462 29 3/4 x 76 3/4 5.75 25 5/8 x 32 5116 6.44 25 5/8 x 36 3116 11.11 2611/16 x 73 9/16 24 5/8 x 35 VNC28210 33314 x 36 314 2.53 29 5/8 x 12 5/16 3.33 29 5/8 x 16 3/16 5.34 3011/16 x 33 9/16 28 5/8 x 15 VNC2832 33314 x 40 3/4 2.94 29 5/8 x 14 5116 3.74 29 5/8 x 18 3/16 6.10 3011/16 x 37 9/16 28 5l8 x 17 VNC28310 33 3/4 x 48 3/4 3.77 29 5/8 x 18 5/16 4.56 29 5/8 x 22 3/16 7.63 3011/16 x 45 9/16 .28 5/8 x 21 VNC2842 33 3/4 x 52 314 4.18 29 5/8 x 20 5116 4.98 29 5/8 x 24 3/16 8.40 3011116 x 49 9/16 28 518 x 23 VNC2846 33314 x 56 3/4 4.59 29 5/8 x 22 5/16 5.39 29 5/8 x 26 3/16 9.16 3011/16 x 53 9/16 28 5/8 x 25 'VNC2852 33 3/4 x 64 3/4 5.86 29 5/8 x 281/2 6.21 29 5/8 x 30 3116 10.69 3011/16 x 61 9/16 28 518 x 29 VNC2856 33314 x 68 314 5.82 29 5/8 x 28 5/16 6.62. 29 5/8 x 32 3116 11.46 3011/16 x 65 9/16 28 518 x 31 VNC 2856 CS 33 3/4 x 68 3/4 4.59 29 5/8 x 22 5/16 7.86 29 5/8 x 38 3116 11.46 3011116 x 65 9/16 28 518 x 25 TOP 28 5/8 x 37 BOTTOM VNC 2862 33 3/4 x 76 3/4 6.65 29 518 x 32 5/16 7.44 29 5/8 x 36 3116 12.99 30 11116 x 73 9/16 28 5/8 x 35 VNC30210 37 3/4 x 36 314 2.88 33 5/8 x 12 5116 3.78 33 5/8 x 16 3/16 6.11 3411/16 x 33 9/16 32 5/8 x 15 �518i'x�i1�3DL 3h1�1" 3 1t7 - VNC30310 37 3/4 x 48 3/4 4.28 33 5/8 x 18 5116 5.18 33 5/8 x 22 3116 8.74 3411/16 x 45 9/16 32 518 x 21 VNC k 52 3/4 4.74 33 5/8 x 20 5/16 5.65 33 5/8 x 24 3/ifi 9.62 341 i/16 x 49 9/16 32 5/8 x 23 VNC3052 37314 x 64 3/4 6.14 33 5/8 x 26 5116 7.05 33 5/8 x 30 3116 12.25 3411/16 x 61 9/16 32 5/8 x 29 VNC3056 37 3/4 x 68 3/4 6.61 33 5/8 x 28 5116 7.52 33 518 x 32 3/16 13.12 3411/16 x 65 9/16 32 518 x 31 VNC3056 CS 37 3/4 x 68 3/4 5.72 33 5/8 x 241/2 8.92 33 518 x 38 3/16 13.12 3411116 x 65 9/16 32 5/8 x 25 Top 32 5/8 x 37 BOTTOM VNC3062 37 3/4 x 76 3/4 7.55 33 5/8 x 32 5116 8.45 33 5/8 x 36 3/16 14.88 3411/16 x 73 9/16 32 5/8 x 35 VNC3432 413/4 x 40 314 3.74 37 5/8 x 14 5/16 4.75 37 5/8 X 18 3/16 7.87 3811/16 x 37 9/16 36 5/8 x 17 VNC34310 41314 x 48 314 4.78 37 518 x 18 5/16 5.80 37 5/8 x 22 3/16 9.85 3811/16 x 45 9/16 36 5/8 x 21 VNC3442 41314 x 52 3/4 5.31 . 37 518 x 20 5J16 6.32 37 5/8 x 24 3t16 10.84 3811/16 x 49 9/16 36 5/8 x 23 'VNC3446 413/4 x 56 3/4 6.40 37 5/6 x 24112 6.84 37 5/8 x 26 3/16 11.82 3811/16 x 53 9/16 36 518 x 25 VNC3452 413/4 x 64 3/4 6.88 37 5/8 x 26 5116 7.89 37 5/8 x 30 3/16 13.80 3811/16 x 61 9/16 36 5/8 x 29 VNC3456 CS 413/4 x 68 3/4 6.40 37 5/8 x 241/2 9.98 37 5/8 x 38 3116 14.79 3811/16 x 65 9/16 36 5/8 x 25 TOP 36 5/6 x 37 BOTTOM VNC 3462 413/4 x 76 3/4 8.44 37 5/8 x-32 5116 9.46 37 5/8 x 36 W 6 16.76 38 11/16 x 73 9/16 36 5/8 x 35 VNC3846 45 3/4 x 56 314 6.45 41 518 x 22 5116 7.57 41 5/8 x 26 3/16 13.15 4211/16 x 53 9/16 40 5/8 x 25 'Single Balance CS windows use 4/6 top sash ®o 0- MIP-3425 7/00 Permit# Permit Date REScheck Software Version 3.7 Release 1 b C©MPI,ance Certificate pF NEt7jY H M. Project Title: Lawson Addition �� �O�•p'F Report Date:12126105 Cr.r Energy Code: New York State Energy Conservation Construction Code 1 J'F 097 N 0� Location: Warren County,New York Constnictibn Type: Detached 1 or 2 Family gOFES, Heating Type: Non-Electric , Glazing Area Percentage- 6% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/Contractor: 9 Heresford Lane Richard and Theresa Lawson Patrick Burke Queensbury,NY 12804 Home Owner Patrick Burke Construction 9 Heresford Ln 936 Bay Road Queensbury,NY 12804 Queensbury,NY 12804 518-745-0019 Assembly • - - • •• Upstairs Ceiling:Flat Ceiling or Scissor Truss: 500 30.0 0.0 18 Downstairs Ceiling:Flat Ceiling or Scissor Truss: 100 30.0 0.0 4 Laundry Rm Wall 1:Wood Frame,16"o.c.: 96 19.0 0.0 5 Window 1:Vinyl Frame:Double Pane with Low-E: 11 0.390 4 Laundry Rm Wall 2:Wood Frame,16"o.c.: M 19.0 0.0 8 Door 1:Solid: 21 0.150 3 Rec.Rm Wall:Wood Frame,16"o.c.: 160 19.0 0.0 8 Window 1:Vinyl Frame:Double Pane with Low-E: 15 0.390 6 Window 2:Vinyl Frame:Double Pane with Low-E: 15 0.390 6 Rec.Rm&Storage Wall:Rec.Rm&Storage Wall: 200 19.0 0.0 12 Bath&Storage Wall:Bath&Storage Wall: 160 19.0 0.0 9 Window 1:Vinyl Frame:Double Pane with Low-E: 8 0.390 3 Laundry Room Floor:All-Wood JoisUrruss:Over Unconditioned 240 30.0 0.0 8 Space: Rec.Rm Floor(portion):All-Wood Joist/Truss:Over 180 30.0 0.0 6 Unconditioned Space: Statement of Compliance:The proposed building represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. CAM ,t��"'C`AiA/(, d' D,7 O,fir BuilderiDesigner Company Name Date Lawson Addition Page 1.of 4 REScheck Software Version 3.7 Release 1 b Inspection Checklist' Date: 12/26/05 Ceilings: ❑ Upstairs Ceiling:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: ❑ Downstairs Ceiling:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: Abovq-Grade Walls: ❑ Laundry Rm Wall 1:Wood Frame,16"o.c.,R-19.0 cavity insulation Comments: ❑ Laundry Rm Wall 2:Wood Frame,16"o.c.,R-19.0 cavity insulation Comments: ❑ Rec.Rm Wall:Wood Frame,16"o.c.,R-19.0 cavity insulation Comments: ❑ Rec.Rm&Storage Wall:Rec.Rm&Storage Wall,R-19.0 cavity insulation Comments: ❑ Bath&Storage Wall:Bath&Storage Wall,R-19.0.cavity insulation Comments: Windows: ❑Window 1:Vinyl Frame:Double Pane with Low-E.U-factor:0.390 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑Window 1:Vinyl Frame:Double Pane with Low-E,U-factor:0.390 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑Window 2:Vinyl Frame:Double Pane with Low-E.U-factor:0.390 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 1:Vinyl Frame:Double Pane with Low-E,U-factor:0.390 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Solid,U-factor.0.160 Comments: Floors: ❑ Laundry Room Floor:All-Wood Joist(Truss:Over Unconditioned Space,R-30.0 cavity insulation Comments: ❑ Rec.Rm Floor(portion):All-Wood Joist/rruss:Over Unconditioned Space,R-30.0 cavity insulation Comments: Lawson Addition _ �� Page 2 of 4 Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder. ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and doling equipment and service water heating equipment must be provided. ❑ Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. s Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-11. ❑ RetirmAucts in unconditioned attics or outside the building must be insulated to R-8. ❑ Supply ducts in unconditioned spaces must be insulated to R-11. ❑ Return duds in unconditioned spaces(except basements)must be insulated to R- ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: ❑All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181 B. F;cception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ' ❑The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters are required for each dwelling unit. Fireplaces: ❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1: _- Swimming Pools: ❑All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from c non-depletable sources.Pool pumps require a time dock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. Lawson Addition Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes . Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 Q.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ff) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure(femperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5. 1:0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Lawson Addition _ Page 4 of 4 la f 3D r j �.. ..: D TO virto o , A t s ao +2 TOWN OF Q „' 3