Loading...
2004-015 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development-Building & Codes (518) 761-8256 CERTIFICAT E Perrrut:Number _:,P20040015 Date Issuedc Thu_rsday,=August 26, 2004 This is-to_certi that.work re uesfed.to_be done as shown b. .Permit Number fy q_ y. _.__ P20040015 has been completed. -^ - Tax Map Number: 523400-296-008-0001--031-002-0000 Location: 9 MAYFIELD Ct N 14,ELS GROUP LLC THE Applicant: MICHAELS GROUP LLC THE This structure may be occupied as a: By Order of Town Board Fireplace TOWN OF QUEENSBURY Garage - 2 Cars Attached Townhouse . Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community.Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040015 Application Number: A20040015 Tax Map No: 523400-296-008=0001-031-002-0000 Permission is hereby granted to: MTCHAFT,S CTROTTP TJ,C THF, For property located at: 9 MAYFIELD Ct in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: MICHAELS GROUP LLC THE 10 BLACKSMITH Dr Fireplace MALTA, NY 12020-0000 Garage-2 Cars Attached Townhouse $201,875.00 Total Value $201,875.00 Contractor or Builder's Name /Address Electrical Inspection Agency MICHAELS GROUP ST JITE 1 10 BLACKSMITH Dr MALTA. NY 12020 Plans&Specifications 2003-015 LOT 45 HSE#9 MAYFIELD COURT 1584 SQ FT TOWNHOUSE WITH 2-CAR ATTACHED GARAGE $263.76 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday, January 20, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town eensb Tye d , January 20, 2004 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement i I Cheek Residential Plan Review: One&Two Family Dwellings YIN/N/A Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size vl Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space / Above/Below grade,5.7 sq.ft. v Grade,5.0 sq.ft. 24 (h)x 20"(w)min. "Max.Height.above floor esidential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofing/Waterproofing Materials On Plans Foundation Drainage On Plans,if required 6"Drop in 10' Exterior Grade aming Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where e uired e and Snow shield 24"Inside Exterior Wall'/24"Inside Knee Walls P tforms At Exterior Doors Stairway Headroom 6' 8' All Stairs 36"Width Stair Run and Rise t Winder Run and Rise ; piral Not Allowed From 2n Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance all Width,36"min. andrails More Than One Riser On Open Sides /Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas , Garage Fire Separation arage Floor Sloped ttic Access oof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping.Level Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed Building Permit Application Town of Qucensbury—Dept of Community Development, 742 Bay Road, Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. Permit File No. C7 L _ I No inspection will be made until applicant has received a lice Paid $ � VAIN building permit. All applicants' spaces on this Rec. Fcc Paid $ application must be completed and must appear on the Reviewed By: , lie application form. Applicant:TIAE VIA" Owner: P C Address: `Q g �i '�ry Address: ��E Phone# (155e)&IL- f,gS i l Phone# ( ) - t` 2004 TOWN OF QUEENSBURY BUILDING AND CODE Property Location: Lot Number: 45_/ House Number 9 Subdivision Name: WP,,g Tax Map Number: . New Building: residence /commercial Estimated Market Value of Construction: $_ 2_01 1 `a-7 5 ❑ Addition: residence/ commercial If an Addition, what will use of new addition be? ❑ Alteration: residence/ commercial ❑ No change to exterior size: residence/coni'I ❑ Other work(describe ) Check OCeupaneyillforination 1"Floor- 2"` Floor Other Iloor 'Total Below sq. fit. sq. ft• sq. fit. Square Feet ❑ Single family dwelling ❑ Two family dwelling jK: Townhouse 1 5164 15 e 4- ❑ dDL Multifamily dwellingl #01 units ❑ Office ❑ Mercantile ❑ ManufaCtUrill ❑ 1 car detached garage ❑ 2 car detached garage ❑ 3 car detached garage ❑ 1 car attached garage J4 2 car attached garage ¢Zp 42.0 ❑ 3 cat-attached garage ❑ Storage building- — commercial ❑ Storage building- residential ❑ Other Will any second-hand or ungraded lumber be used? If so, for.what? ��_D Type of Heating Sysletn: electric/ oil / gas wood /forced hot air/ baseboard/other: Number oi'PirelVaces to be installed 1 Number of)[Voorlstones to be installed N. � List below the person(s)responsible for supervision of work as regards to building codes: Name _ Address Phone Number IGIC�I �� . Q— Plunlbcr _ ,kc�I�`�I�ihc� lam_ t�_ Mason �-Zt- Electrician �.i►C �C � � . Ca�-L—Z Dcclaratioii: please sign below after you have carefully Wild the statement• To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code, the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied wily, whether spcciried or noted,and thatsuch work is authorised by the owner. Further, it is understood that I/we shall submit, prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes,an its Btrilt Serve)by a licensed surveyor;drawn to scale,showing actual location of all iicw construction. Signature:— � owner,owner's agent,architect,contractor Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY , (518)761-8205 Application for Fuel Burning Appliances & Chimneys applicable to solid fuel & vented gas,appliances Date t 1 120 Permit No. Application is hereby made to'the Building&..Codes Office.for the issuance of a Building and Use Permit pursuant to the New York State Fire Prevention.and Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requiretnents and also will allow,all inspectors to enter premises to perform required inspections. NOTE to applicant: Rough-in and Final Inspections are required. Applicant Information Fuel Burning Appliance Information (circle appropriate words) Name: Stove: wood coal pellet gas Filrep�ce, iased--, Address: l ' ;fitt i4`fit► l-t i a`r �i,�el�.lace. factory-b wood ' MAI s' -1 ',.I y 1 Z G)Z D Fireplace,.masonry: wood gas Furnace: wood gas oil Phone: E�'J c'l y C 1 If non-masonary applicance, please provide" Owner: Manufacturer Name: Address: Model Number: Chimney Information Phone: (circle appropriate words) Masonry block brick stone Flue tile Cteel size: inches Exact Address: of construction or installation Factory-Built Manufacturer name: Model Number: Note: Listed By: Number: Construction IInstallation must con orin to NYS Fire Prevention &Building Indicate(circle) chimney material: Code..Consult available Town of Queensbury Handouts regarding required inspections. Double ivall / Triple wall Insulated / Direct vertri ;t Chimney Liner IC�s.�ifer'�®r.Depaz�mex�t—2'o�r�:of Qzzee�terbury, ATe�Yoram: Fire Marshal Code# $Collected S Refunded Receivedfi•on: (refunded to): .' address: ----- A 173 3389 (190) Public Safety / A 233 2655 (230)Minor Sltles _ DATE; If Yi�r�a�N2o- 701V . 6"oa. !�"r .� White(Applicant) / Green(Fire Marshal) - / Yellow(Bldg. Dept.) / Pink&Goldenrod(Cashier's Dept.) Aug.26. 2004 2:26PM QBY WATER TEWATER No. 6611 P . 4/4 Ac,G v av V3 T p 2004 Town of Queensb cc{� rtment of Wastewater o�po R� Sanitary Sewer Conn i spection Sheet Permit # Date �'a•�. Name Address Contractor YES NO Trench 644 Back Water Valve Depth Y�`— U-Trap Outside Cleanout� 3 Vented Septic Tank Pumped Sump Pump IN SERVICE Comments; /I' s' Inspected By: tv SKETCH V� �D M" 3� S Queensbury Building & Code Enforcement - Residential Final Inspec •on (P;�00 Office No. (518)761-8256 Arrive: am/p Depart: y am/pitiL� Date Inspection request received: — Inspector's Initials: NAME: �Ci� v 1 PERMIT#: LOCATION: DATE: _ TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more a)stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum ''/z" , Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18" above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety lzin /Window in stairwells safety glazing Interior Smoke Detectors: / Every level: / Every Bedroom: J Outside every bedroom area: inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss, draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/<hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"a cess, 1 s . ft.-150 s . ft. vents Building No./Addy s vi ib fr m roa Final Electrical A! Site Plan /Varianc ehjirdd Final Survey Plot Plan p As Built Septic System/Sewer Dept. Inspection Sticker I ebV, Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Permanent L:1PamW\BuildinQ&Codes\Insvection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 TOWN OF QUEENSBURY BUILDING '&: CODE ENFORCEMENT 742 BAY ROAD QUEENSBURY • NY 12804 (516)745=4447 ARRIVE: DEPART: INSP: UJ FINAL INSPECTION REPORT COMMERCIAL ------ MULTIPLE DWELLING (hotel, motel, apt. complex) DATE INSPECTION REQUEST RECEIV NAME LOCATION //'y/CC DATE PERMIT A (/ `( —D/-S TYPE OF STRUCTURE FOOTINGS _BACKFILL_ FRAMING_ PLUMBING_ INSULATION NIA YES NO CHIMNEY "B" VENT HEIGHT PLUMBING VENT FIXTURES ROOFING EXTERIOR FINISH HEATING HOT WATER RELIEF VALVES FLOORS FOUNDATION INSULATION INTERIOR STAIRS RAILINGS STOCKROOM ENCLOSURE FIRE DEMISE WALLS PENETRATION FIRE DAMPERS CEILING FIRE STOPPING FIRE DOORS CLOSERS EXIT DOOR HARDWARE EXIT STAIRS/RAILS PLATFORM ELEVATOR HANDICAPPED ACCESS HANDICAPPED BATHS HANDICAPPED PARKING FINAL ELECTRICAL SITE PLAN VARIANCE REQ. SURVEY PLOT PLAN IF RE OK TO ISSUE C/O OR C C Town of Queensbury Fire Marshal 742 Bay Road Queensbury,NY 12804 r 761-8205/761-8206 1 0C) fax 745-4437 n Factory Built Gas Replace/Stove Inspection Retort Notice:New York State requires that all UL Listed$factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. 1Permnit# _01 S Schedule lnspeetion---2—,f1'S Time Q.aria pm aiaytime, Inspector ���/ Naive � - Address_ Rough In__F`inalL. Appliance Manufacturer.---- Model# Direct Vent Factory wilt Chimney flue Size Double Wall Triple Fall Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Firestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above my combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension (if ally) Mantel Height above f/p opening Witness Operation Tank Placement(if LP) Nubile BtaihaingiDepi, — - Yeilor� fast er Pink—Fire Marshal MAP REFERENCE: i WAVERLY PLACE SUBDIVISION DATED AUGUST 24, 2000 j LAST REVISED JANUARY 19. 2001 BY VAN DUSEN do STEVES LAND SURVEYORS, LLC i 1 !r 1 YAGN8TjC I I t �' 44 S� \ C 6� UTILITIES z \, 45 I 10,455 sq.ft. f co cn6a cc, 0.24 acres r o 47 46CO w 9 T 3kro 7" S11 i I 1 MEADOWBROOK ROAD ;6-1 q OA y C))5 5W35 , lAW, a a Du Date: AUGUST 24, 2004 DNADn,D�ZEO ALTERATION OR ADDITION To A SURVEY Scale 1"=30' MAP BEARING A LICENSED LAND SURVEYORS SEA&IS A Map of a Survey made for VIOLATION OF SECTION nos,SUB-aNSION z OF THE NEW TORN STATE EOUCAIION LAw.- oear Corts FROM"0"rMAL or Mrs-0VRVff St e v e s 'C�BE SCONSIDEREDINDICATE TO BE VALID TRUE CORES' ���NS PhD"��S` THAT Sarah A. Skinner THIS sLAtvEY WAS PREPARED NT ACCORDANCE wTM THE EXISTING CODE OF PRACTICE FOR LAND SURVEYORS ADOPTED Land Surveyors LABY DS NEW YOWOM STATE ASSOCIATIORTMATION S1 PROFESSIONAL LAND SURVEYORS R CERTif'E SURVEY SHALL RUN 0l,A SHEET TO 771E PERSON FOR MHOM THE 518lVEY 5 PREPARED,AND ON HIS BEHALF TO THE TITLE COMPANY,GOVERNMENTAL 169 Haviland Road Queensbury, New York 12804 AGENCY AM LENDING INSTITUTION LISTED HEREON'AND Town of Queensbury, Warren County, New York TO MC A55.'GWCS Or me IeNOwO IA'STRUrON SKINNER (518) 792-8474 New York Lie. No. 50135 NO. DATE DESCRIPTION DWG. No. 99312-45 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: _ (Ar 5� Queensbury Building&Code Enforcement Arrive: am/p D art: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: �i\ry TG PERMIT #: O �-� '0 S LOCATION: 'C\ ` : i INSPECT ON: - - a 0-0 TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min. Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Co er Commercial 0o er, CPVC,Pex One and Two-Family nsulation/Residential Check/Commercial Check P Pro er Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Rough Plumbing / Insulation. Inspection Report 11 � Office No. (518) 761-8256 Date Inspection request received: / Queensbury Building&Code Enforcement : Arrive: am/p apart: 1 1.` am/pm. 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: \ PERMIT #: LOCATION: INSPECT ON: - TYPE OF STRUCTURE: Y N, N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest A 98. ,. U(/ connection for 15 minutes Cleanout every 100 feet/chan a of direction W ter Supply Piping C ooper Commercial Coo 'er,CPVC,Pex One and Two-Family Insulation-/=Residential Check/Commercial Check Pro er Vent,Attic Vent ,q- (,D"rA)C Duct/Hot Water Piping Insulation yQS� If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: "Tyz'� L:\SueHemingway\Building.C6des.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: / I Queensbury Building&Code Enforcement Arrive: am/ p�e�art: m/pm 742 Bay Road,Queensbury,NY 1.2804 Inspector's Initials:? 2'� z"/ NAME: PERMIT#: LOCATION: ��c_h �z_. INSPECT ON: !aJ v TYPE OF STRUCTURE: Y N 'N/A COMMENTS Framing S`�prpP l V Jacktuds/Headers racing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hole Firestopping 1615-7 Penetration sealed lll�i� 16 inch insulation in cavity min. Garage Fire Separation House side11/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORTvIS\Framing Firestopping Inspection Report.doc January 28,2003 Framing /Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: a pm epart: pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: C,G(.q��5 �Q� PERMIT#: a l LOCATION: A`t riC e-C2 67 INSPECT ON: TYPE OF STRUCTURE: Framing Y N, N/A COMMENTS _ Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour irestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report L( Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm epart: am/pm il r 742 Bay Road, ueensbury, NY 12804 Inspector's Initials: l NAME: PERMIT#: f� LOCATION: INSPECT ON: - TYPE OF TRUCTURE: Y N N/A COMMENTS Fr ming - ack Studs/Headers Bracing/Bridging mod. �[(1 Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6'ft. or less on center Ice and s shield 24 inches from wall Fire se ration 1, 2, 3 hour Fire all 2, 3, 4 hour 'restopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side t/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pn Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: f CSL PERMIT #: LOCATION: �' INSPECT ON: `7 - TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron, Cop er Drain/Vent/ Comm. Plu mg Vent/Vents in Place ou h Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper, CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Town of Queensbury Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone (518) 761-8205 Fax(518) 745-4437 Fire Marshal's Inspection Deport Request Q V 1S SCHEDULE Received: Permit# INSPECTION ON: Name: la. G)aL,_,+U - AM PM ANYTIME Location: 0) QA - _ _ PPROVED _ N/A YES NO — COMMENTS EXITS AISLE WIDTHS EXIT SIGNS-_NORMAL - BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM _ FIRE SUPPRESSION SYSTEM_ -_- HOOD INSTALLATION - INTERIOR FINISHES _ STORAGE COMPRESSED CLEARANCE TO SPRINKLERS �- CLEARANCE TO HEATING UNITS _ CLEARANCE TO ELECTRICAL_ REQUIRED SIGNAGE MERGENCY PLAN MAXIMUM OCCUPANCY/SIGN p CHIMNEY — --DfUe� '�&N I MASONRY ROUGHiN V FINAL CHIMNEY FACTORY BUILT ROUGH IN FINAL WOOD STOVE ROUGHIN FINAL _ VENTED GAS APPLIANCE ROUGH IN FINAL FIREPLACE -t --�--- , MASONRY ROUGH IN OK THIS DA E OK FOR OO NOT OK - --- FINAL — FIREPLACE FACTORY BUILT ✓✓ROUGH IN ------------�— INSPECTED BY FINAL COMUEV/C HRISJMORD/LETTERS2001/FIREMARSHALINS PECTIONREPORT11022001 WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY Rough Plumbing / Insulation Inspection Report c� Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm De a C a�m � 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: ` PERMIT #: f(� LOCATION: INSPECT ON: - - TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast IrWCopper Drain/Vent/Comm. Plupffmg Vent/Vents in Place ou k,Plumbin /Nail Plates 1 % inch min.Drain Size W shing Machine Drain 2 inch min. ead or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cjeanout every 100 feet/change of direction ater Supply Piping Cooper Commercial Cooper, CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FQRMS\Rough Plumbing Insulation Report.doc November 17,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials-.l- � NAME: v PERMIT#: C� LOCATION: INSPECT ON: -' - � TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Bacicfill Approval mbing Under Slab PV /Cast/Copper G� o dation Insulation Interior/Exterior R Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report 1 Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/prp Depart: _ �Sam/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: �� i NAME: � � PERMIT#: 06 0 LOCATION: i INSPECT ON: TYPE OF STRUCTU : ; Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofmg/Watelpro fang Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width _6 inches above footing mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PV /Cast/Copper oundatio Insulation Inte 'or/Exterior R- N14lL Rough Grade 6 inch drop within 10 ft. L:�,SueHemingway\Bui]ding.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ m Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: �\ \,\10,A) CPERMIT#: n O —U l-5 LOCATION: (' INSPECT ON: — TYPE OF STRU URE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anc or Bolts 6 ft. or less on center ce and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: , Queensbury Building&Code Enforcement Arrive: am/p Depart: m/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: —l.5 PERMIT#: LOCATION:AQY INSPECT ON: S— 17-11 O TYPE OF STAUt URE: qComments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing 40 j,j. Type of Dampproofmg/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab P C/Cast/Copper Foundationlnsulation tenor Exterior R- �J Rough Grade 6 inch drop within 10 ft. LASuellemingway\Building.Codes.Inspection.FORMSToundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request eceived: Queensbury Building&Code Enforcement Arrive: am/pm D art: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: M 1 \ PERMIT#: V LOCATION: �r INSPECT ON: TYPE OF STR CTURE: Comments Y N N/A ootings � , Piers Monolithic Slab Reinforcement in Place 2 The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection requ st A received: Queensbury Building&Code Enforcement Arrive: a d We'Depart: J pm 742 Bay Rd., Que.ensbury,NY 12804 Inspector's Initials. NAME: , \� U ( PERMIT#: 0 r �� LOCATION: Msc f INSPECT ON: TYPE OF STRUCT Comments Y IN N/A ootings Piers Monolithic Slab Reinforcement in Place Z The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofmg/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHenningway\Building.Codes.InspectionTORMSToundation Inspection Report.doe January 28,2003 1 Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release lc REC � �® Data filename:F:\SHARE\Design\Energy Calc\WAVERLY PLACE\9 Mayfield Court.cck TITLE:WP 321 Sage aipKl 1 52p04 COUNTY:Warren TOWN O1F AND CBU Y STATE:New York BUILD HDD:7635 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE: 01/05/04 DATE OF PLANS:January 5,2004 PROJECT INFORMATION: 9 Mayfield Court Waverly Place _ Queensbury,N.Y. COMPANY INFORMATION: •,' , � The Michaels Group 10 Blacksmith Dr. . f f. Malta,NY 12020 a NOTES: %PC, 0 Slab on Grade Condition N. Silverline 2900 windows COMPLIANCE:Passes Maximum UA=473 Your Home UA=403 14.8%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA lst fl walls:Wood Frame, 16"o.c. 1938 19.0 0.0 98 2x opt.Mbr(K):Vinyl Frame,Double Pane with Low-E 21 0.400 8 lx opt.Mbr(L):Vinyl Frame,Double Pane with Low-E 30 0.400 12 2x Kitchen(K):Vinyl Frame,Double Pane with Low-E 21 0.400 8 Kitchen door-#7: Glass 40 0.350 14 Ix Dining(A): Vinyl Frame,Double Pane with Low-E 34 0.400 14 2x Family (D): Vinyl Frame,Double Pane with Low-E 27 0.400 11 2x opt Family(X): Vinyl Frame,Double Pane with Low-E 10 0.400 4 Ix opt.Family(F):Vinyl Frame,Double Pane with Low-E 6 0.400 2 Ix Study(L):Vinyl Frame,Double Pane with Low-E 30 0.400 12 Ix Bath (R): Vinyl Frame,Double Pane with Low-E 6 0.400 2 4 Ix opt.Bed#2(P): Vinyl Frame,Double Pane with Low-E 17 0.400 7 2x opt.Bed#2(K):Vinyl Frame,Double Pane with Low-E 20 0.400 8 Entry door-#IA: Glass 29 0.350 10 Garage door-#20:Solid 19 0.240 5 opt.Bed#2 bay walls:Wood Frame, 16"o.c. 15 19.0 0.0 1 opt.Mbr.bay wall:Wood Frame, 16" o.c. 15 19.0 0.0 1 Floor 1:Slab-On-Grade:Unheated 180 6.0 131 Insulation depth:4.0' opt.Bed#2 bay ceiling:Raised or Energy Truss 17 30.0 0.0 1 opt.Mbr.bay ceiling:Raised or Energy Truss 20 30.0 0.0 1 Ceiling 1:Raised or Energy Truss 1663 30.0 0.0 53 Furnace 1:Forced Hot Air,92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Cons vation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are at est ng that e best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compli n e wit is ode. Builder/Designer Date 0-- REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release 1c DATE: 01/05/04 TITLE:WP 321 Sage Bldg. Dept. Use Ceilings: [ ] 1. opt.Bed#2 bay ceiling:Raised or Energy Truss,R-30.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. [ ] 2. opt.Mbr.bay ceiling:Raised or Energy Truss,R-30.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. [ ] 3. Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. Above-Grade Walls: [ ] 1. 1st fl walls:Wood Frame, 16" o.c.,R-19.0 cavity insulation Comments: [ ] 2. opt.Bed#2 bay walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 3. opt.Mbr.bay wall:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Windows: [ ] 1. 2x opt.Mbr(K): Vinyl Frame,Double Pane with Low-E,U-factor:0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 2. Ix opt.Mbr(L): Vinyl Frame,Double Pane with Low-E,U-factor: 0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 3. 2x Kitchen(K):Vinyl Frame,Double Pane with Low-E,U-factor: 0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 4. Ix Dining(A):Vinyl Frame,Double Pane with Low-E,U-factor: 0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 5. 2x Family(D): Vinyl Frame,Double Pane with Low-E,U-factor:0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 6. 2x opt Family(X): Vinyl Frame,Double Pane with Low-E,U-factor:0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 7. Ix opt.Family(F): Vinyl Frame,Double Pane with Low-E,U-factor: 0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 8. lx Study(L):Vinyl Frame,Double Pane with Low-E,U-factor: 0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 9. lx Bath(R):Vinyl Frame,Double Pane with Low-E,U-factor: 0.400 For windows without labeled U-factors,describe features: . #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 10. lx opt.Bed#2(P):Vinyl Frame,Double Pane with Low-E,U-factor:0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 11. 2x opt.Bed#2(K): Vinyl Frame,Double Pane with Low-E,U-factor:0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: Doors: [ ) 1. Kitchen door-#7: Glass,U-factor: 0.350 Comments: [ ] 2. Entry door-#lA: Glass,U-factor: 0.350 Comments: [ ] 3. Garage door-#20:Solid,U-factor:0.240 Comments: Floors: [ ] 1. Floor 1: Slab-On-Grade:Unheated,4.0' insulation depth,R-6.0 continuous insulation Comments: Slab insulation to extend down from the top of the slab to at least 4.0 ft.OR down to at least the bottom of the slab then horizontally for a total distance of 4.0 ft. Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade) insulation and extends at least 6 in.below grade. Heating and Cooling Equipment: [ ] 1. Furnace 1:Forced Hot Air,92 AFUE or higher Make and Model Number Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values,glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ) Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces (except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [ ] All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State ,the Residential Code of New York State or the New York City Building Code ,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral'heat trap or is part of a circulating_system. . [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 °F must be insulated to the levels in Table 2. i Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2"Runouts 1"and Less 1.25"to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)