blower door results
Testing Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@locascioenergysolutions.com Building Information: Project ID:158 Cleverdale Address:158 Cleverdale Rd Queensbury, NY 12804 Geo-Tag Data:Latitude: 43.465648 Longitude: -73.638748 Timestamp: 2021-01-06 12:14:05 Customer Information: Name:Jean Hoffman Address: Measured Leakage:1,530.4 CFM50 Test ID:158 Cleverdale Purpose of Test:50 Pa Env. Leakage Measured ACH50:2.92 Effective Leakage Area: 84.2 in² Building Volume:31,485.0 ft³Enclosure Surface Area: 3,854.0 ft² Coefficient (C):120.4 Exponent (n): 0.650 (assumed) Test Standard:RESNET 380 One-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 68 °F Altitude: 375.0 ft Outdoor Temp: 30 °F Time Average Period: 10 seconds Test Date and Time:2021-01-13 12:12:20 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -3.7 -50.0 -52.9 -49.2 -80.5 1,615.1 Ring A Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3173 Custom Calibration Date: 2020-02-10 Pressure Gauge:DG1000 Serial #: 5193 Calibration Date: 2020-01-16 Deviations from Standard: None Comments: None Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.7.3 (91), © 2020 The Energy Conservatory, Inc.