Loading...
JB201133.0052.Grout Compressive Strength Test.2020-12-29.Rpt.0052GROUT COMPRESSIVE STRENGTH TEST REPORT Report Number: Service Date: Report Date: Task: Client JB201133.0052 12/29/20 01/05/21 30 Corporate Cir Ste 201 Albany, NY 12203-5169 518-266-0310 Rosetti Acquisitions LLC Attn: Christopher Falvey 427 New Karner Rd Albany, NY 12205 Fowler Square SI and CMT Bay Road and Blind Rock Road Queensbury, NY 12804 Project Project Number: JB201133 Sample Information Sample Date: Sampled By: Weather Conditions: Sample Size: Sample Location: Sample Time:12/29/20 1130 Abdulaziz Abdalla 30 Accumulative Yards:Batch Size: Prefrabicated Tub Placement Location:Staircase No.1, perimeter walls grouted solid Form Material: Samples Plumb: Cardboard Form No. Units:1 Yes Temperature Range: Specified Strength:psi @ days Mix ID: Supplier: Batch Time: Material Information Plant: Field Test Data Test Grout Temp. (F): Ambient Temp. (F): Result Specification 28 FG Package Pavement 1100 Truck No.:Ticket No.: 9 60 50 Slump (in): 3,000 Laboratory Test Data No. Date Age Area (lbs) Load Strength Compressive ID Received Date Tested (days)(sq in)(psi) Maximum SpecimenSet Tested By 1 A 12/30/20 01/05/21 7 11.73 41,600 3,550 ADB 1 B 12/30/20 01/26/21 28 12.08 1 C 12/30/20 01/26/21 28 11.97 1 D 12/30/20 Hold 11.94 Initial Cure:Final Cure:Inside Moist Room Comments:Spec Mix FG3000, 3000 psi @ 28 days Temp inside of heated enclosure 50 degrees , Temp outside of heated enclosure 30 degrees Samples Made By: Dente Group - A Terracon Co. Obtain sample of grout used as wall fill, perform required field tests and cast compressive strength samples.Services: Reported To: Contractor: Report Distribution: (1) Rosetti Acquisitions LLC, Christopher Falvey (1) 260 Structural Engineering, Dan Thomas (1) BBL Construction Services, Eric Weatherwax (1) BBL Construction Services, Ryan Etue (1) BBL Construction Services, Scott Lounsbury (1) Galusha & Sons LLC, Drew Stevens (1) Galusha & Sons LLC, James Campagnone Materials Department Manager M. McHenry BBL Bobby w. BBL Reviewed By: Test Methods:ASTM C 31, ASTM C39, ASTM C109, ASTM C138, ASTM C143, ASTM C1019, ASTM C1064 Dente Group - A Terracon Co. Rep.: Abdulaziz Abdalla The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0009, 11-16-12, Rev.6 Page 1 of 1