2004-101 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20040101 Date Issued: Friday, June 18, 2004
This is to certify that work requested to be done as shown by Permit Number P20040101
has been completed.
Tax Map Number: 523400-309-006-0001-014-000-0000
Location: 50 VETERANS Rd
Owner: LARRY CLUTE
Applicant:
LARRY CLUTE �
This structure may be occupied as a:
j By Order of Town Board
Garage - 1 Car Attached TOWN OF QUEENSBURY
Single,Family Dwelling j .�
/� A—
Director of Building&Code Enforcement
I
- TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20040101 Application Number: A20040101
Tax Map No: 523400-309-006-0001-014-000-0000
Permission is hereby granted to: TARRY CT,T TTF,
For property located at: ALTA Ave
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: LARRY CLUTE
13 DAWN Rd Garage- 1 Car Attached
Single Family Dwelling $85,000.00
QUEENSBURY,NY 12804-0000 Total Value $85,000.00
Contractor or Builder's Name /Address Electrical Inspection Agency
CLTTT'E ENTERPRISES INC.
13 DAWN Rd
OITEENSBITRY_ NY 12804
Plans&Specifications
2004-101 Tax Id No. 309.6-1-14 and 13
936 SQ FT SINGLE FAMILY DWELLING (2 lots combined which goes from Alta Ave. thru to Veterans
Road). House appears to front on Veterans Road.
$142.32 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday, March 30, 2005
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To o eensb s rch 30, 2004
SIGNED BY . for the Town of Queensbury.
r .y
Director of Building&Code Enforcement
jDuuumg Term -c xppucanon
Town of Queensbury—Dept of Community,Development,742 Bay Road,Queensbury,NY
(518)761-8256
A permit must be obtained before beginning construction. Permit File No. �`1 J
No inspection will be made until applicant has received a Fee Paid $
valid building permit. All applicants'spaces on this Rec.Fee Paid $
application must be completed and must appear on the Reviewed By:
application form.
Applicant: Owner.
Address: Address:
21� Lid
Phone#(_) - —T Phone#
7>77
Property Location: Lot Number. / House Number—/
Subdivision Name: Tax Map Number:
7,�r'1 . iCl tam •-tI -
New Building: residence /commercial 'Estimated Market Value of Construction:$ aT6
o Addition: residence/ commercial If an Addition,what will use of new addition be?
u Alteration: residence/ commercial
t] No change to exterior size: residence/com'l
o Other work(describe )
Check OCCIIpanCyTnfonntion 1' Floor 2 Floor Other floor Total
Below sq ft. sq.ft. sq.ft,_ Square Feet
Single fauu'ly dwelling mot , 9 3
o Two#pA!y dwelling
v Townhouse
o Multifamily dwelling
#of units
a Office
ci Mercantile
o Manufacturin
13. 1 car detached garage
v 2 car detached garage
0 -3 car detached garage
1 car attached garage :24-0
v 2 car attached garage
0 3 car attached garage
v Storage building-
commercial
o Storage building-
residential
13 Other
What is the proposed height of the structure = feet inches
Will any second-hand or ungraded lumber be used? If so,for what? 5I`:C V'e
Type of Heating System: electric/ o' gas/ od forced hot air_�Saseboard/other.
Number of ire laces to be installed ("L Number of Woodstoves to be installed_
List below the person(s)responsible for supervision of work as regards to budding codes:
Name Address PhoneNumber
Builder
Plumber
Mason
Electrician
DecIarationi please sign below after you have carefully read the statement:
To the best of my knowledge the statements contained in this application,together with the plans and specifications
submitted,are a.trot and complete statement of all proposed work to be done on the described premises and that all
provisions of the Btril ,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied
with,whether sp or noted,and that such work is authorized by the owner. Further,4 is understood that Uwe shall
submit;prior Certificate of O ancy or C4ficate of Compliance being issued,as requested by the Zoning
Adn ' 7&Y
or Director of ding and Cod As Butlt Survev by a licensed surveyor,drawn to scale,showing actual
locatio new
S' owner,owner's agent,architect;contractor
Application for Permit—Septic Disposal System
Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256
1. OWNER INFORMATION: __.�...._
+� I Office Use
Location of installation:
File Permit No'-)-00`7��/
� l
Tax Map No.
f
Fee Paid
Owner's Name: �.4^-z�l•--� �-- � )�,P. ?____ _... . __ __. - - __._._...._
Address:
2. INSTALLER'S NAMEJ�e �. r-.G � '� r PHONE NO. Z`LZ - �Z?
3. RESIDENCE INFORMATION: (circle year of dwelling,indicate#bedroom(s)and multiply#of
bedrooms with applicable gallons per bedroom to equal total daily flow)
Zow)
Year of House: No of Bedrooms x Computation = Total Daily Flow
1980 or older x 150 gal/bdrm =
1980-1991 x 130 gaYbdrm =
1991-present IV7- x 110 gal/bdrm = -"Z 2�
Garbage Grinder Installed yes_ J ni <
Spa or Hot Tub Installed yes_ / no
4: PARCEL INFORMATION: (circle applicable information&indicate measurements)
ToDopranhv S tare Ground Water Bedrock or Impervious Material Do Water Su 1
lat sand at what depth at what depth munici
Rolling oam" _____feet -feet well
Steep slope clay if well;water supply
slope other from any septic system
depth: absorption is ft.
other
Percolation Test: (To be completed by licensed professional engineer or architect)
Rate: minute per inch
5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed
professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size
of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub.
Septic Tank: (.W a gallon(min.size 1,000 gal.)
Tile Field: each trench . Total System Length: ( 50 ft.
Seepage Pit(s): number of size of each: ft. by ft.
Size gf Stone to be used: # / depth or thickness feet
Bed System Size: x
Alternative System: length and/or size
6. HOLDING TANK SYSTEM: (if required)
Number of tanks: / Size of each: gallons /TOTAL" Capacity: gallons
Note: Alarm System and associated electrical work must be inspected by a Town approved
electrical inspection agency.
7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read)
For your protection,please note that pursuant to Section 136 29 of the Code of the Town
of Queensbury,any permit or approval granted which is based upon or is granted in
reliance upon any material misrepresentation or failure to make a material fact or
circumstance known by or on behalf of an applicant,shall be void.
I have r the regulation with re sp t to this application and agree to abide by these and all
re q ' ements of the Que sb Sanitary Sewage Disposal Ordinance.
Signa ure of responsible person Date
ENERGY CODE COMPLIANCE APPLICATION Ll_
TOWN OF QUEENSBURY, WARREN COUNTY �l
9000 HEATING DEGREE DAYS /
Compliance Methods:Part 5 -Acceptable Practice Method—1&2 Family Dwellings(only)
Part 6*-Thermal Rating—Component trade Offs 1&2 Family Dwelling;
Multi=:Fau ly Dwellings(3 Stories or less)
Part 4*-Design by Component Performance,Commercial Buildings-Hi
Rise Residential
*Requires submission of worksheets
APPLICANT'S NAME: c� PROPERTY LOCATION:
PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE-
I. Gross Floor Area-- .3 square feet
2. Type of heat- Electric . Oil_ �� Gas Other
3. Is building mechanically cooled? yesNo
4. Percentage of area of windows and doors Over 17% >-15',' Under 17%
` 5. R VALUES FOR INSULATION GIVEN BELOW MUST CORRESPOND TOR VALUES AS
SHOWN ON PLANS SUBMITTED:
a: Roof R 77,z)
b. Exterior walls R t1
C. Glazed areas R Z.
d. Exterior doors R (1Y.5
e. Floors over unheated spaces R —
f. Edge of slab on grade(heated building) R
g. Basement/cellar walls(above grade) Rom_
h. Basementicellar walls(below grade) R t-1
i. Heating/cooling-ducts-piping in unheated space R k_j�5
6. Service(domestic)hot water heating device
Conforms to minimum efficiency per code Yes No
TE CONTR L MAXIMUM SETTING 140—WILL NOT BE EXEEDED
pp ' "gtmat Date Phone Number
�3 / --Z Z S _7XI 77
INSPECTOR'S REMARKS:
i
4
Job g to ,Adress: ' Date:
Owner: LI-A-s'7 �4 L�j\ Application No. File No.
r--7
WINDOW SCHEDULE
.;'.'' .;,....t. ., ., t �i, .•o'. . `. .,. �,Opej�tn$5pGo7�ic��gn¢....,� �., ,,,, .. .. .,a>.,. ...... . . .
Window Window Mfg, Window Unit or Rough 'i Rough SQ FT SQ;FT SQ FT :Clear. : Clear „; Special Hardware or
Number or Name Model Stock Opening �Openuig r GlassNi`sib Uettt EgresslGlear Qpenuig t2penitrg Height instructions
Letter on Or Type Number Widih, 'i Hetg t �l;' Opc�ntng Widxh In ' In Itc hes
Plan Call Size n
�•� r I hes
` 1/c�
57
-THIS LINE HAS EXAMPLES OF SAMPLE ENTRIES
A Andersen Narcohpe 3062• 3':21/3" 6'5'/" 15,30 8,3.6 ' 601 34 4t;5/35" Temliered
t Double i 11M6 Glazing
a
.\SueHemingwny\9uilding.Permit.PORMS\Window Schedule.doc
t
fib Site Address: .� QS Date: 71, lk� dcs�
Owner; '
���.-.�� ,r �.__�J�. Application No. File No.
Building Permit — Calculation Sheet
Natural Light, Ventilation & Emergency Egress Requirements
Habitable Area of Req. Light Actual ' - Req,,Vent Actual ' Sq.Ft. Remarks
Room Roo F ; Room Li ht
m ; a 8%of g 4%of Room Vent R Opening for
in
Al.,i, ,;.
mzw Area Square Fy;4i; Area Square ;; :;; Egress
Square #` g
q s Footage y Footage
Feet Prt �•},
U:mac ,•'�-!?; `;
W
..2"
�•
L:\SueHeminpvay\Building.Permit.FORMSW at,Light.Ventil.Caleulation,Sheet.doe
Permit Number
REScheck Compliance Certificate Checked By/1)ate
New York State Energy Conservation Construction Code
REScheckSoflware Version 3.5 Release 1d
Data filename:A:\\26 x 36 Ran Veterans Road.rck
PROJECT TITLE:26 x 36 Ranch
COUNTY:Warren
STATE:New York
HDD:7635
CONSTRUCTION TYPE:Detached 1 or 2 Family
HEATING.TYPE:Non-Electric
DATE:03/16/04
DATE OF PLANS: 03/16/2004
PROJECT DESCRIPTION:
Veterans Road
Queensbury,NY 12804
DESIGNER/CONTRACTOR:
Clute Enterprises.Inc.
13 Dawn Road
Queensbury, NY 12804
COMPLIANCE:Passes
Maximum UA=339
Your Home UA=237
30.1%Better Than Code(UA)
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1:Flat Ceiling or Scissor Truss 936 30.0 . 0.0 33
Wall 1:Wood Frame, 16"o.c. 1972 19.0 0.0 112
Window 1:Vinyl Frame:Double Pane 67 0.490 33
Door 1: Solid 21 0.230 5
Door 2:Glass 21 0.490 10
Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 936 19.0 0.0 44
Furnace 1:Forced Hot Air,90 AFUE
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,
specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the
New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and
signed this page,they are a V g t at to the best of his/her knowledge,belief,and professional judgment,such plans or
specifications are in compliance 'th' Code.
Builder/Designer Date I f 6 �(�
REScck l-nspection Checklist
New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release Id
DATE: 03/16/04
PROJECT TITLE:26 x 36 Ranch
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation
Comments:
Above-Grade Walls:
[ ] 1. Wall 1:Wood Frame, 16" o.c.,R-19.0'cavity insulation
Comments:
Windows:
[ ] 1. Window 1:Vinyl Frame:Double Pane,U-factor:0.490
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? [ ]Yes[ ]No
Comments:
Doors:
[ ] 1. Door 1: Solid,U-factor: 0.230
Comments:
[ ] 2. Door 2: Glass,iI-factor:0.490
Comments:
Floors:
[ ] 1. Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-19.0 cavity insulation
Comments:
Heating and Cooling Equipment:
[ ] 1. Furnace 1:Forced Hot Air,90 AFUE or higher
Make and Model Number
Air Leakage:
[ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly
with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a
3"clearance from insulation.
Vapor Retarder:
[ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:,
[ ] Supply ducts in unconditioned attics or outside the building must be insulated to R 11.
[ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6.
[ ] Supply ducts in unconditioned spaces must be insulated to R-11.
[ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2.
Insulation is not required on return ducts in basements.
Duct Construction:
[ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics
(adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted.
Exception:Continuously welded and locking-type longitudinal joints and seams on ducts
operating at less than 2 in.w.g.(500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
temperature set point of the largest zone.
Electric Systems:
[ ] Separate electric meters are required for each dwelling unit.
Fireplaces:
[ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
provisions of the Building Code of New York State ,the Residential Code of New York State or
the New York City Building Code ,as applicable.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table 1:` Minimum Insulation Thickness for Circulating Hot Water Pipes.
r Insulation Thickness in Inches by Pipe Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5. 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature - 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD (Building Department Use Only)
.L.. ...... . i-"_. L i...... !
I Y. or ixi + e ' s4P CV I I
I I _. .i , I
' _
[ . . I II
..._........i..
�\ I hr� � I
�. �+
I rJ ,
L. .. .I n l jh.4 ib 5 uQt Tsai C111 E?r papa"i ?.
S)?L
,QCfS�!?�+'rl� Ifii•;aIO, i,, C QQ ..I I, tr
,
I I I
t I ' I J'
1 I ITT RE I ATE
i
I I I
Si
I. I i i
i
i
I
i i I
I
I
I i I I + I I L .-. i ..._ .... I i I. .. .. _.
i .. .. � .
:
;
1 i
I
I I i i
i
I I I
I I I i i I I
I...... i.... i. .... . L.. I, ... �.. .
! I I _ �
I i 1. I I I i
Im7an—I —t! 7 y I ...I ..I ..
01
.. . . . .
i I I I Id
1
? 1 I I I I ! 1 I I �, '� r`.�" I ' ..�„= I ----i'--,.,"-�'�----� ,�. ! .. ..�-•,. I.. _� � I i .. ... i
i 1 .
. .. .IIi J-4
1 . I I.. . . .
j L L
.ff..... I'I .
-.... ... Ii.. ..
! . 1
.•
,
ni. ! I
I T. ' i ----
._..
it
I I :
I
I 1 I I I I i
,
_.I ._ I ... I . _i. .._.I . ..L. . i..
!_... I. .
I i I I i I I I I I I f i I I j. �. of I i
I i.
i r I I
_ ---i j I _.. i... _.
,
I �
..... .. .......
. .. III ..._.ii.. .. lI
...'I .
I1.1. . . I I I . ,... ii...... .....,..I ..........
.... .Ii .
...
r ;
I ,
I
...-... , _ _.I
I.
I 1 '
I,I IIII,i II l ii .I; �n i -, =.�..�.- �,- _•I--'� aIs. p-::_a-iIw...
.I .� -- I .i I. I I _
I i . I . I . K_- I . _ _ _ _ ++4
I!II
+1 _
•I .. I.
_.
-,Queensbury Building & Code Enforcement - Residential Final n�spection
Office No.(518)761-8256 Arrive: am/p D part. ,LS am/pm
Date Inspection request received: 1 7 U t/ Inspector's Initials:
NAME: 414LIkl —�'1 �� PERMIT#:
LOCATION: DATE: _
TYPE OF STRUCTURE:
Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6"
Roof Complete/Exterior Finish Com lete
Guard 30 in. or more @ stairs, decks,patios
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in. or more
Exterior Finish Complete
Interior/Exterior Railings 34 in,to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock Underside minimum %"
Gypsum
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post or Wall
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft. or within line of site
Oil Furnace shut-off at enhance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: / Every Bedroom:
Outside every bedroom area:
Inter Connected: / Batter backup:
Carbon Monoxide Detector
Bathroom Fans, if no window
Plumbing fixtures
Foundation insulation
Floor truss, draft stopping finished basement 1,000 sf
Emergency egress below rade
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/4 hour fire door/door closer
Duct work Sealed properlyl
Gas Logs in Sealed or Glass Enclosure
Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24Y acg6ss, 1 s . ft.-150 s .ft. vents
Building No./Addresjv'&g,forn.ro
Final Electrical
Site Plan /Varianc-efre4hired
Final Survey Plot Plan
As Built Septic System/Sewer Dept. Inspection Sticker
Flood Plain Certification, if required
Okay to issue C/C or C/O Temporary/Permanent J
L:\PamW\Building&Codes\Insuection Forms\Res.Final Inso. form 2.docLast printed 2/12/04
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection reque t received:
Queensbury Building&Code Enforcement Arrive: am/p /' Depart: pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: ( L�
NAME: PERMIT#:
LOCATION: INSPECT ON:TYPE OF STRUCTU
Comments
Y N/A
ngs
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour <J d U ` �� j J � 5K
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for"wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade:6 inch drop within 10 ft.
L:\SueHeniingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003
TOWN OF QUEENSBURY
BUILDING '& CODE ENFORCEMENT
} 742 BAY ROAD
QUEENSBURY NY 12804
(518)745-4447
ARRIVE: DEPART: INSP:
FINAL INSPECTION REPORT
COMMERCIAL ------ MULTIPLE DWELLING
(hotel, motel, apt. complex)
DATE INSPECTION REQUEST RECEIVED:
NAME /
LOCATION47 A DATE PERMIT A L r D
TYPE OF STRUCTURE
FOOTINGS _BACKFILL_ FRAMING_ PLUMBING_
INSULATION
N/A YES NO
CHIMNEY "B" VENT HEIGHT
PLUMBING VENT FIXTURES
ROOFING
EXTERIOR FINISH
HEATING HOT WATER
RELIEF VALVES
FLOORS
FOUNDATION INSULATION
INTERIOR STAIRS RAILINGS
STOCKROOM ENCLOSURE
FIRE DEMISE WALLS PENETRATION
FIRE DAMPERS
CEILING FIRE STOPPING
FIRE DOORS CLOSERS
EXIT DOOR HARDWARE
EXIT STAIRS/RAILS
PLATFORM ELEVATOR
HANDICAPPED ACCESS
HANDICAPPED BATHS
HANDICAPPED PARKING
FINAL ELECTRICAL
�NALSURVVEY
IANCE RE .
PLOT PLAN IF RE
OK TO ISSUE C/O OR C C
Septic Inspection Report -
i
Office No. (518)761-8256 Date Inspection request received:
QueensburyiBuilding&Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Rd, Queensbury,NY 12804 Inspector's Initials:
NAME: ' PERMIT NO.: l 1 r
LOCATION: INSPECT ON:
RECHECK:
Comments and/or diagram
Soil Type: Sa ay
T e of Water unicipal/ ell Water
Waterline sea ce ft.
Well separation distance ft.
Other.wells: ft.
-Absorption Field: Total length ft.
Length of each trench ft.
Depth of trenches ft.
Size of Stone
Seepage Pits: Number
Size: x
Stone Size:
Piping . Si Type
Building to tank G
Distribution Box % Field/Pit w n
Opening Sealed: N/Partial
Location/Separations
Foundation to tank ft.
Foundation to absorption ft.
Separation of Pits ft.
Conforms as per Plot Plan Y N
Location of Syste on Property:
Front Rear Left Side Right Side
Middle Front dle Rear
S stem Use Statu
Approved
Partial Approved and needs to.be re-inspected,please call the Building&Codes Office
Disapproved
L:1SueHemingwaylBuilding.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003
t s,
WA
i
— — — — ---- an
— ---
JI
Oil
j
s
f 222www
s
— t �
;,�
Rough Plumbing / Insulation In ��-
� � Inspection Rep
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/p epart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials: ,
NAME: Q PERMIT #:
LOCATION: o
d INSPECT ON: (�
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1,R-2,R-3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 % inch min.Drain Size
WasWg Machine Drain 2 inch min.
E "a 'ff-Supply Test
ram and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply PipingA�-5 /q
Cooper Commercial
Cooper, CPVC,Pex One and Two-Family
4Insul'tiori`%Residential Check/ Commercial Check
Pro _er Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
L:\SueHemingway\Building.Codes.hispection.FORMS\Rough Plumbing Insulation Repott.doc November 17,2003
Framing/Firestoppmg Inspection Report
Office No. (518)761-8256 Date Inspection request received: J
Queensbury Building& Code Enforcement Arrive: am/p epart: 7z Al-aTh/pni ( �
742 Bay Road,Queensbury,NY 12804 Inspector's Initials:
NAME: �(�-t"L� PERMIT#: C�_X
LOCATION: - � INSPECT ON:
TYPE OF STRUCTURE:
Y z
Framing N/A COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
I %2(w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches fiom wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Irestoppm
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L
4
L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
Framing /Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/nrrLi Depart: m/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: Lu L'' PERMIT#: I
LOCATION: INSPECT ON: Z
TYPE OF STRUCTURE:
Framing 1`V
Y N N/A COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
'1 %2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
chor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LASueHemingway\Building.Codes,Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
Framing /Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection request received: �-PJZ3
Queensbury Building:&Code Enforcement Arrive: am/p epart: " am/pm
742 Bay Road,Queensbury,NY 12804 Inspector's Initials.
NAME: ( c-1►-�—� PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE: .
Framing
Y N l N/A COMMENTS
� .
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in. .
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
c an sno s I d 24 inches from wall
Fire separation 1, 2,3 hour
Fire wall.2, 3,4 hour ,
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage.Fire Separation
House side '/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade .
L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection reque t received: - U
Queensbury Building&Code Enforcement Arrive: am/p Depar am/pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT#: i —
LOCATION: INSPECT ON: �
TYPE OF STRUCT RE: Q- ,
`5y' -T-7) Comments
30S . &-1--lq�(13
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Inforcementin Place •
Foundation Damp proofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
_6 miLp0 for wet areas under slab
-Mac l 11 Approva
Plumbing Uri er a
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
LASueHemingway\Building.Codes.Inspecti on.FORIVISToundation Inspection Report.doc January 28,2003
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: 1
Queensbury Building&Code Enforcement Arrive: am/ , Depart: am/pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:V
NAME: PERMIT#: / ^
LOCATION: &A I ALL INSPECT ON: L
TYPE OF STRUCTURE: S�
Comments
Y N/A
otings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible or
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
1.2 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
LASueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003