JB201133.0052.Grout Compressive Strength Test.2020-12-29.Rpt.0052Rev1GROUT COMPRESSIVE STRENGTH TEST REPORT
Report Number:
Service Date:
Report Date:
Task:
Client
JB201133.0052
12/29/20
01/26/21 Revision 1 - 28-day results
30 Corporate Cir Ste 201
Albany, NY 12203-5169
518-266-0310
Rosetti Acquisitions LLC
Attn: Christopher Falvey
427 New Karner Rd
Albany, NY 12205
Fowler Square SI and CMT
Bay Road and Blind Rock Road
Queensbury, NY 12804
Project
Project Number: JB201133
Sample Information
Sample Date:
Sampled By:
Weather Conditions:
Sample Size:
Sample Location:
Sample Time:12/29/20 1130
Abdulaziz Abdalla
30
Accumulative Yards:Batch Size:
Prefrabicated
Tub
Placement Location:Staircase No.1, perimeter walls grouted
solid
Form Material:
Samples Plumb:
Cardboard Form No. Units:1
Yes
Temperature Range:
Specified Strength:psi @ days
Mix ID:
Supplier:
Batch Time:
Material Information
Plant:
Field Test Data
Test
Grout Temp. (F):
Ambient Temp. (F):
Result Specification
28
FG
Package Pavement
1100
Truck No.:Ticket No.:
9
60
50
Slump (in):
3,000
Laboratory Test Data
No.
Date Age Area
lbs)
Load Strength
Compressive
ID Received
Date
Tested (days)(sq in)(psi)
Maximum
SpecimenSet Tested
By
1 A 12/30/20 01/05/21 7 11.73 41,600 3,550 ADB
1 B 12/30/20 01/26/21 28 12.08 49,130 4,070 ADB
1 C 12/30/20 01/26/21 28 11.97 47,890 4,000 ADB
Average (28 days) 4,040
1 D 12/30/20 Hold 11.94
Initial Cure:Final Cure:Inside Moist Room
Comments:Average compressive strength of 28 day Prism complies with the specified strength. **NP = Not Performed
Spec Mix FG3000, 3000 psi @ 28 days
Temp inside of heated enclosure 50 degrees , Temp outside of heated enclosure 30 degrees
Samples Made By: Dente Group - A Terracon Co.
Obtain sample of grout used as wall fill, perform required field tests and cast compressive strength samples.Services:
Reported To:
Contractor:
Report Distribution:
1) Rosetti Acquisitions LLC, Christopher Falvey (1) 260 Structural Engineering, Dan Thomas
1) BBL Construction Services, Bobby Chatterton (1) BBL Construction Services, Eric Weatherwax
1) BBL Construction Services, Ryan Etue (1) Galusha & Sons LLC, Drew Stevens
1) Galusha & Sons LLC, James Campagnone
Materials Department Manager
M. McHenry
BBL
Bobby w. BBL
Reviewed By:
Test Methods:ASTM C 31, ASTM C39, ASTM C109, ASTM C138, ASTM C143, ASTM C1019, ASTM C1064
Dente Group - A Terracon Co. Rep.: Abdulaziz Abdalla
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
CR0009, 11-16-12, Rev.6 Page 1 of 1