JB201133.0057.Mortar Compressive Strength Test.2020-12-30.Rpt.0057Rev1MORTAR COMPRESSIVE STRENGTH TEST REPORT Report Number: Service Date: Report Date: Task: Client JB201133.0057 12/30/20 01/27/21 Revision 1 - 28-day results 30 Corporate Cir Ste 201 Albany, NY 12203-5169 518-266-0310 Rosetti Acquisitions LLC Attn: Christopher Falvey 427 New Karner Rd Albany, NY 12205 Queensbury, NY 12804 Bay Road and Blind Rock Road Fowler Square SI and CMT Project Project Number: JB201133 Sample Information Sample Date: Sampled By: Weather Conditions: Sample Size: Sample Location: Sample Time:12/30/20 1330 Abdulaziz Abdalla 34 2"x2"x2" Tub Placement Location:Staircase No.1 10" CMU wall mortar joints. Starting course at second floor deck Test Mold Material: Curing Procedure: Other - See Comments ASTM C 109 psi @ days Mix ID: Supplier: Batch Time: Material Information Plant: Field Test Data Test Mortar Temp. (F): Ambient Temp. (F): Result Specification Mortar Type:S 1,800Specified Strength:28 Type S Mortar Package Pavement 1300 45 50 Laboratory Test Data No. Date Age Area (lbs) Load Strength Compressive ID Received Date Tested (days)(sq in)(psi) Maximum Set Specimen Tested By 1 A 12/31/20 01/06/21 7 4.04 9,990 2,470 ADB 1 B 12/31/20 01/27/21 28 4.08 11,700 2,870 ADB 1 C 12/31/20 01/27/21 28 4.08 12,430 3,050 ADB Average (28 days) 2,960 Initial Cure:Inside Final Cure:Moist Room Comments: Note: The indicated Specified Strength above is for laboratory batched and cast specimens under controlled conditions. Strength tests of field cast specimens are to be used to monitor trends and batch to batch consistency of mortar per ASTM C 270 and are not intended as criteria to determine the acceptance or rejection of the mortar as installed. Average compressive strength of 28 day Cube complies with the specified strength. Package Pavement, Type S Mortar, silo bag mix, 1800 psi @ 28 days Samples Made By: Dente Group - A Terracon Co. Obtain a sample of masonry mortar used during construction and cast 2-inch cube specimens for consistency verification.Services: Reported To: Contractor: Report Distribution: (1) Rosetti Acquisitions LLC, Christopher Falvey (1) 260 Structural Engineering, Dan Thomas (1) BBL Construction Services, Bobby Chatterton (1) BBL Construction Services, Eric Weatherwax (1) BBL Construction Services, Ryan Etue (1) Galusha & Sons LLC, Drew Stevens (1) Galusha & Sons LLC, James Campagnone Materials Department Manager M. McHenry BBL Bobby w. BBL Reviewed By: ASTM C109, ASTM C780Test Methods: Dente Group - A Terracon Co. Rep.: Abdulaziz Abdalla The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0008, 11-16-12, Rev.6 Page 1 of 1