Signed Inspection Report (01-28-2021) (5).pdfINSPECTION WORKSHEET (RESFINAL-007870-2021) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0507-2020 Case Module:Permit Inspection Date:Thu Jan 28, 2021 Inspection Status:Failed Inspector:Dyer, Charles Inspection Type:Residential Final Inspection Job Address:Parcel Number:323 LUZERNE RD Queensbury, NY, 12804 308.12-2-58 Contact Type Company Name Name Concrete Contractor Ottens Concrete Granted Permission Bell, Jamie Granted Permission Bell, Marie Framing Contractor Top Notch Builders Roofing Contractor Apex Solar Power Architect G. Peter Jensen Architect Contractor Precision Contruction Plus Siding Contractor LaRose, Mike Primary Owner Bell, Marie Applicant Bell, Jamie Checklist Item Status General Comments Failed 1/28/21 spoke with contractor, project is put on hold until spring, nothing has occurred since permit being issued. Project will consist of garage addition and roof over porch. Contractor is Precision construction-Steve Bonhote and Peter Sluck. CO in Bedrooms w/Gas Failed Jan 28, 2021 Page (1) INSPECTION WORKSHEET (RESFINAL-007870-2021) Checklist Item Status 4 inch Building Number Address visible from road Failed Chimney Height / B Vent / Direct Vent Location Failed Chimney Rain Cap Installed Failed Fresh Air Intake Failed Fresh air supply 3' from grade Failed 3" Plumbing Vent through roof minimum 18 inch Failed Outside Spigots have Air Gap Failed Roof Complete / Exterior Finish Complete Failed Platform at all exterior doors Failed Handrail 4 or more risers Failed Guards at stairs,decks,patios 30" + above grade Failed Guard at stairwell at 34" or more Failed Jan 28, 2021 Page (2) INSPECTION WORKSHEET (RESFINAL-007870-2021) Checklist Item Status Window guards req:<2' above floor/6' above grade - quick release installed Failed Guard at deck, porches 36" or more Failed Handrail Termination at Newell Post or Wall Failed Interior/Exterior Railings 34 to 38 Failed Wood deck: 2'+ from grade dia bracing required - H/C ramp compliant Failed 4+ Deck Joist Ledger Connections-24" From Ends Failed Deck Ledger-Bolted per Code Failed Grade away from foundation: 6" down, 10' out Failed 6" clearance to sill plate Failed Gas Shut-off Exposed & Regulator (18) Above Grade Failed HVAC Vent Terminal 10' from Lot Line & Openings Failed Jan 28, 2021 Page (3) INSPECTION WORKSHEET (RESFINAL-007870-2021) Checklist Item Status Dryer Duct Max Length 35', Labeled Over 35'Failed Interior privacy/trim/doors/main entrance 36 Failed Bathroom / Kitchen Watertight Failed Low flow toilet 1.3 gal/flushing cycle - showerhead/faucet Failed Safety glazing: w/in 5' of tub/shower - stairwell win/adj to drs Failed Smoke Detectors:Failed CO in Bedrooms w/Gas Failed Smoke Detectors 3' from Kitchens & Baths R314 Failed Every level, Every bedroom Failed Outside every bedroom area Failed Battery backup: _____Failed Inter Connected Failed Jan 28, 2021 Page (4) INSPECTION WORKSHEET (RESFINAL-007870-2021) Checklist Item Status Carbon Monoxide Detectors:Failed CO Detectors within 10' of all sleeping areas Failed Attic Access 22 x 30 minimum Failed Attic Access Insulation = Attic R- Value Failed Attic Access Gasketed Failed Foam in basement/attics covered w/thermal barrier Failed Crawl Space Access 18 x 24 Failed Bathroom Fans, if no window Failed Plumbing fixtures Failed Backflow Preventors where required Failed Foundation insulation to floor Failed Jan 28, 2021 Page (5) INSPECTION WORKSHEET (RESFINAL-007870-2021) Checklist Item Status Energy Sticker on Elec. Panel:R-Val. & Heating Sys Failed All Hot Water Systems: 3/4" or larger piping R-3 Failed Duct work sealed properly Failed Intake Openings Failed Range Hood 400+ cfm-Fresh Air REQUIRED Failed Blower Door Test Certification Failed HRV or ERV Installed per Bedroom Requirements Failed Floor truss, draft stop- fin base 1,000 sq. ft.Failed Emergency egress below grade Failed Furnace shut-off w/in 30 ft. or w/in line of site Failed Oil Furnace Shut-Off at Entrance to Furnace Area Failed Propane Tank: Proper Setback from Prop Line/Struct Failed Jan 28, 2021 Page (6) INSPECTION WORKSHEET (RESFINAL-007870-2021) Checklist Item Status Furnace/Hot Water Heater operating Failed Low water shut-off boiler Failed Relief Valve ,Heat Trap/Water Temp 110 deg or less Failed Encl. Stairs Sheetrock Underside minimum ½ Gypsum Failed 1/2" Gypsum or House Wall and Gable Failed 5/8" Type X with Living Space Above Failed 20 Minute Fire Door/Self-Closing Hardware Failed Seals on Garage Doors, esp. Wood Failed Basement stairs closed rise greater than 4 inches Failed Basement Egress: 5s.f. window w/sill or Bilco door Failed Basement ceiling covered 2x8 fl joist or less Failed Jan 28, 2021 Page (7) INSPECTION WORKSHEET (RESFINAL-007870-2021) Checklist Item Status Jack posts in basement lagged at top and bottom Failed Fireblocking at fl joist 80 s.f. or less Failed Garage Floor Pitched Failed 1/2" Gypsum-Bsmt Ceiling<2x10 Frame/TJI/Fl. Truss Failed Gas Log In Sealed or Glass Enclosure Failed Fin Elect; Energy Saving Light Bulbs 50 Percent Failed CSST/other piping in conduit if buried,if required Failed Final Survey Plot Plan Failed Arc Fault Breaker Habitable Spaces Failed Flex Gas Pipe Bonding Failed As Built Septic System Failed Sewer Dept. Inspection Sticker Failed Jan 28, 2021 Page (8) INSPECTION WORKSHEET (RESFINAL-007870-2021) Checklist Item Status Site Plan / Variance required Failed Flood Plain Certification, if required Failed Fuel Tanks above flood plain elevation Failed Buried Fuel Tanks anchored in flood zone Failed Truss ID Signage Installed at Electrical Meter Failed OK to Issue Temporary C/O Failed OK to Issue C/O Failed Jan 28, 2021 Page (9) Dyer, Charles