proposed SERVICES
73 Sheridan Street, Glens Falls,NY 12801
Phone-518-796-2515
December 1, 2020
Project# 325
George Drellos
Sanitary Sewer Service
Queensbury, NY 12804
Re: Proposed Replacement Septic IE C
249 Fuller Road, Queensbury,NY
D
Dear George: EC 0 2 2020
TOWN OF QUEENSSURY
At your request, we have reviewed your proposed repl 14 '•`_1 6$y f aEgesign of the
existing 3-bedroom cottage at 249 Fuller Road in Queensbury. As per our conversa ion the
residence has an existing failed septic system.
We have reviewed the proposed replacement septic system design and we agree that a standard
absorption bed is acceptable. Based upon a design flow rate of 330 GPD and a percolation rate of
1 to 5 minutes, you will need a minimum of 367 sf of absorption area. We recommend using 15
ft wide by 30 ft long absorption,bed with 3 — 25 ft long laterals. The absorption system can be
constructed with a new 1,000-gallon septic tank, new distribution box, and 4-inch diameter
perforated pipe and stone. A vent will be required on the end of the absorption bed due to the
depth of the existing septic tank.
Please feel free to contact me at 796-2515 if you have any questions and that you for your
assistance with this request.
Sincerely,
l
Thomas R. Center Jr, P.E.