Loading...
proposed SERVICES 73 Sheridan Street, Glens Falls,NY 12801 Phone-518-796-2515 December 1, 2020 Project# 325 George Drellos Sanitary Sewer Service Queensbury, NY 12804 Re: Proposed Replacement Septic IE C 249 Fuller Road, Queensbury,NY D Dear George: EC 0 2 2020 TOWN OF QUEENSSURY At your request, we have reviewed your proposed repl 14 '•`_1 6$y f aEgesign of the existing 3-bedroom cottage at 249 Fuller Road in Queensbury. As per our conversa ion the residence has an existing failed septic system. We have reviewed the proposed replacement septic system design and we agree that a standard absorption bed is acceptable. Based upon a design flow rate of 330 GPD and a percolation rate of 1 to 5 minutes, you will need a minimum of 367 sf of absorption area. We recommend using 15 ft wide by 30 ft long absorption,bed with 3 — 25 ft long laterals. The absorption system can be constructed with a new 1,000-gallon septic tank, new distribution box, and 4-inch diameter perforated pipe and stone. A vent will be required on the end of the absorption bed due to the depth of the existing septic tank. Please feel free to contact me at 796-2515 if you have any questions and that you for your assistance with this request. Sincerely, l Thomas R. Center Jr, P.E.