Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2004-224
TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 ' CER'TIFICA'T'E OF OCCUPANCY Permit Number: P20040224 Date Issued: Friday, January 07, 2005 This is to certify that work requested to be done as shown by Permit Number P20040224 has been completed. Tax Map Number: 523400-308-010-0001-044-000-0000 Location: 6 WAYNE Ct Owner: ' MARK DELOR Applicant: MARK DELOR This structure may be occupied as a: By Order of Town Board Residential Addition TOWN OF QUEENSBURY _ c Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building-&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040224 Application Number: A20040224 Tax Map No: 523400-308-010-0001-044-000-0000 Permission is hereby granted to: MARK DELOR For property located at: 6 WAYNE Ct in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: MARK DELOR Residential Addition $28,000.00 MARY ELLEN SONCINI Total Value $ 6 WAYNE Ct 28,000.00 QUEENSBURY, NY 12804-0000 Contractor or Builder's Name /Address i Electrical Inspection Agency LINDELL CONSTRUCTION HITDSON FALLS_ NY 12839-0000 Plans&Specifications 2004-224 770 SQ FT RESIDENTIAL ADDITION $92.40 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday, May 12, 2005 I (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the w f Que Tb 1VIa day, y 12, 2004 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Building Permit Application Town of Queensbury-Dept of Community Development,742 Bay Road,Quecnnsbury,NY (518)761-8256 A permit must be obtained before beginning construction. Permit File N . '� No inspection will be made until applicant has received a Fee paid valid building permit. All applicants'spaces on this Roc.Fee Paid $ application must be completed and must appear on the Reviewed By: Application form. Applicant: AlKle .� Zo r Owner: Ala - flalor Address; m ®� Al, � Address: '� i / Phone#( )22Z- Wl Phone#( ) Property Location: Lot NuMber: / House Number--/ lam° aqrw- SubdivisionName: rat, .,�Y[ Tax Map Number:. IO ILO /-'YY a New Building: residence /commercial 'Estimated Market Value of Construction: $ s 00 Addition: residence coinmereial If atl Addition, � e o new a}ditiou be? a Alteration: residence I commercial -- a No change to exterior size: residence/conel O Other work(doscrhe Check OccupancyWormation V1 Floor.. 2DQ Floor Other floor Total Below sq.ft. sq ft. sq:ft. Square Feet Sin e famil dwelling ° o Two fatzvl dwellin a Townhouse o Multifamily dwelling #oAf-uaits a Offee p L 4 Lt i .. ■ 9 a:=. L; a Marcaattle o Meauthcturin R p R 2 0 04 a 1 car detached sarave a 2 car detached gars e 11 a 3 car detached eage a 1 car attached garage a 2 car attached garage a 3 car attached garage a Storage building- commercial' a . Storage building- residential ' a cr What is the ro osed height of the structure feet inches a-f *k P F Will any second-hand or ungraded lumber be used? If so,for what? /I, 6 Type of Heating System: electric/ oil ! gas I wood forced/ baseboard/other: Number of to be installed n Number of j' o stgvg-,to be installed h List below the person(s)responsible for supervision of work as regards to building codes: .Name Address - Phone Number Builder h. o " 3 0 Plumber A , AF A 1 Z7— Mason Electrician lvyt Declaration please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the-plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that 1/we shall submit,prior to a Certificate of Occupancy or Certificate'of Compliance being issued,as requested by the Zoning Administrator or Director of Building and 96des,an s Bunt ury by a.licensed surveyor;drawn to scale,showing actual location of au new co 'o Signal: ' owner,owner's agent,architect,contractor +Job Site Address: (;�` Date: Owner: �,'��G ��'�!�— Application No. File No. —_0 pZ,/ WINDOW SCHEDULE •;:� i � }c. ��'7y�,�'ti t ;-*S � "4F v.�x1�v:1:•. :f� .,. .i.;..:�,•; as >iffi��5�? t7lrat'i Window Window Mfg. Window Unit or `,I;;ttgt; Cb $ 1 SZ $ ;irlear•. ' a1 Q , ale i Special Hardware or Number or Name Model Stockag ,sylalSsZtSYb' a v alss� lea n3ztg Q gl�yg � hi` Instructions Letter on Or Type Number a ° ' Say° 1 "' `" ` " `' x "' "�i ` 1 y +,� a tdt bCC1y� ' s s a a77 4 ac R �� a 1{C �s Ram a f II c < 1 hlrit2cil Plan Call Sizes, la,;�y 4 s� 4a C aro 3c .�cp i a p" c�aa�tiRSa oa oa3 .r�i@ ' �yvau ct�a � ` r�°,� i ya' S as a4 7.'L e t F gg ': a iI ;{S „'R';@:i E �?c orp�Sa9,. .�..:S '.fiis?>";u. f AN C , v� -THIS LINE HAS EXAMPLES OF SAMPLE ENTRIES �z • � T e ;,, :....-r�.;»�Y'�r'':�,�a�,, . : _ .. ;::.� �: �, 4 ,.;.• ,>,�<.,. .,.,. „��,' -�,� .< � I,,,,. � •� rnpere� +.A. ,, :i•� , ��{� '>., t .s yy��, '�" rY.•r. t1a'u..rb�rr ;: 'Yi"• ti:,f4,:. .k' ,.f.. .3'i.rx_,{': •.a ;�., fr.: .r3r:.l :'3..t .ti „Y•6:''', rs,. .�. ,��,:.c: q.� 'xs ;fx�c ;`Y` .E: ....�. ..��_` '�=.,..K<..> .�•vk'•��•::'.-�. .u��r.. .• "'"} ��,t'.�:.,: Glazin' 'S,�:Y;i a:r•'X„q±i:.; ''�'�a.3i` �., � ,r. w.' %w.k#t�r•' � :; .��':�,� , .lw .. fe,` :s z�ia�•a :rr .�t!r, •• �;•�:;" '-�{,:;.. •.cap...• .a,:.�., •�����'�.�... L:\SueHemingway\Building.Permit.FORMS\Window Schedule.doc 6 r � Date: �3 Jo b Site Address: Owner: /yla I//6 Application No. File No. i� Building Permit — Calculation. Sheet Natural Light, Ventilation & Emergency Egress Requirements Habitable Area of Req.Light Actual Req.Vent Actual Sq.Ft. Remarks Room Room 8%of Room Light 4%of Room Vents Opening for in Area Square Area Square Egress Square r Footage � g Feet ��► �� Sdo 21V,51� 4-5 A4,hA J t i tYi} 11 #P 1 N R 2 `� 004 '�URY , 2 L:\SueHemingway\Building.Permit.FORMS\Nat.Light.Ventil.Calculation.Sheet.doc i ENERGY CODE COMPLIANCE APPLICATION TOWN OF QUEENSBURY, WARREN COUNTY 9000 HEATING DEGREE DAYSnow _ ComAiance Methods:Part S -Acceptable Practice Method—1&2 Family Dwellings (only) Part 6*-Thermal Rating—Component trade Offs 1&2 Family Dwelling, Multi-:Family Dwellings(3 Stories or less) Part 4*-Design by Component Performance,Commercial Buildings-Hi Rise Residential *Requires submission of worksheets APPLa C, 'S N PROPERTY LOCATION: �� PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE: 1. Gross Floor Area -11-7© square feet 2. Type of heat- Electric Oil Gas Other 3. Is building mechanically cooled? yes No 4. Percentage of area of windows and doors Over 17% / Under 17% 5. R-VALUES FOR INSULATION GIVEN BELOW MUST CORRESPONDt TO R VALUES AS SHOWN ON PLANS SUBMITTED: a: Roof R 30 b. Exterior walls R C. Glazed areas R �' d. Exterior doors R e. Floors over unheated spaces R f. Edge of slab on grade(heated building) RAl g. Basement/cellar ymlls(above grade) R h. Basement/cellar walls(below grade) R i. Heating/cooling-ducts-piping in unheated space R 6. Service(domestic)hot water heating device Conforms to minimum efficiency per code device No TEMIERATURE CONTROL MAXIMUM SETTING 140—WILL NOT BE EXEEDED ,appli is ig Date / Phone Numberl INSP CTOR'S REMARKS: Sze Queensbury Building & Code Enforcement - Residential Final Inspection �J . -Office No.(518)761-8256 Arrive: am/ epaLLZ�m/pm Date Inspection request received: Inspector's Initials: NAME: PERMIT#: LOCATION: DATE: TYPE OF STRUCTURE: _ Comments N/ ` Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more(a)stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stoppin finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in,x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, I s . ft.-150 s . ft.vents Building No./Address Aisi froinr94d Final Electrical Site Plan /Varia ce rtq-ukkd Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/0 Temporary/Permanent L:\PamW\BuildinQ&CodesUnspection Forms\Res. Final Inso. form 2.docLast printed 2/12/04 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-M anheini,PA 17545 11? MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL . .................... -in Card No. ............................. 84739 Permit No............... Owner... /h 'P ....Cert. Cut . ... ... Location....4 76 ......- ..g....o........ .r e............ ..................................... .............. .. .............. Installation Consisting of... z.. . i . fA...J ............... . ..........................;................... ..A _9.... e—e ..................... ................................................................................................................................................................................... Installed By.......... ..... . . ......................................................Lic.No.................................................. ........ .... ..... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of makin i ections at any time, and if its ' hiC rules are violated,the Company shall have the right oke thi certi icate. Date..... ........ NSPECTOR.Ur......... ................. ............................ Me hpr N-F-P.A.-LA-E-t. Rough Plumbing / Insulation Inspection, Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arriye: _am/pkn Dpart: am/pm . f �V 742 Bay Road, Queensbury,NY 12804 Inspector's Initials:v NAME: M a-,K PERMIT #: LOCATION: INSPECT ON: l r7 TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial _ Cooper,CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duet work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p 1 >Dparst: am/pm 742 Bay Road, Queensbuiy,NY 12804 Inspector's Initials:� ��=1� NAME: PERMIT#: U LOCATION: _ INSPECT ON: 4 TYPE OF STRUCTURE: I Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes G:�;- C) Water Supply Piping r� Copper Commercial Copper, CPVC,Pex One &Two Family Insulation/-Residential Check/Commercial Check — Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: •L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doe January 28,2003 C7- Rou h Plumbing / Insulation Inspection Report g g pp p Office No. (518) 761-8256 Date Inspection request received: �� - Queensbury Building&Code Enforcement Arrive: am/ ,Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials. NAME: PERMIT#: W698 �1 LOCATION: Glt INSPECT ON: -�:�0h�r1. TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place n j Rough Plumbing/Nail Plates Head or Air Supply Test V. �l�A Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial Copper, CPVC, Pex One &Two Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly 'J Cam'` JDvc,TS AL,'y COMMENTS: Allit v k) n) 9,+T't le Iti. . vs i�J .�-� �c, L:�SueHemingwa)ABuilding.Codes.inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Framing / Firestopping Inspection Report r� Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/p epart: am/pm l 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: (eA-/ NAME: PERMIT#: v — � LOCATION: o INSPECT ON: 17—, -- TYPE OF STRUCTURE: '5 Y N N/A COMMENTS raming Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses chor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Suel-lemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p D art U S 5 am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: LOCATION: INSPECT ON: —( TYPE OF STRUCTURE: �p h Y N/A COMMENTS aming 1�1`/� Jack Studs/Headers /kR Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side ''/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.In spection.FORMSTraming Firestopping Inspection Report.doc January 28,2003 LVASSOCIATES LLP Pine West Plaza, Building lA Washington Avenue Extension Albany, NY 12205-5510 Engineers Tel: 518.452.4358 Architects Fax:518.452.9234 Landscape Architects Surveyors Planners May 11, 2004 Town of Queensbury Community Development Department 742 Bay Road Queensbury, New York 12804 Attention: Mr. David Hatin Re: DeLor residence, 6 Wayne Court Building Permit Application Comments Dear Mr. Hatin: Based on ourphone conversation,and faxed sent to us on May 8,2004,we have addressed all your concerns stated in the aforementioned and offer the following.We have provided wind and snow design loads on the revised plans. Also,regarding questions concerning raised heel trusses and R-49 insulation in the ceiling of the proposed addition,we have used an altemate method of complying with the energy code. Our architecture department has prepared the required worksheet to show code compliance using R-30 in the ceiling,R-19 in the walls and R-21 over the unheated garage space to fulfill our obligations,thereby eliminating the need for extra insulation and Raised heel trusses.Lastly,we have provided notes on the plans as requested showing Ice and snow shield on the roof,an attic entrance in the walk in closet and a battery powered carbon monoxide detector as specified. Please find attached worksheets and revised plans for your use.Please contact use immediately if you have further needs or questions. Very truly yours, 1 ' Vollmer Associates LLP I q3 Mark R.Delor,L. . Director of Surveying and Land Development FROM TOWNSEND ASSOCIATES PHONE NO. 5184461995 May. 10 2004 02:37PM P2 Perniit Number REScheck Compliance Certificate Checked13y/Date New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release Id Data filename:F:Trojects(Townsend-Vollmer)\delorhouse\delor.rck PROJECT TITLE.Dclor Addition Herald Square Village,Lot 101 COUNTY:Warren STATE:New York HDD:7635 CONSTRUCTION TYPE:Detached 1 or 2 Pamily HEATING TYPE:Non Electric DATE:05/10/04 DATE OF PLANS:5-10-04 PROJECT DESCRIPTION: 6 Wayne Court Queensbury,NY 12804 DESIGrNER/CON•TItAC"rop': Townsend Architects a divistion of Vollmer Associates,LLP 1.8 Locust Street Albany,NY 12203 COMPLIANCE:Passes Maximum UA-=137 Your 14ome•UA=•119 13.1%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Valne R Value U-Factor UA Ceiling 1;Flat Ceiling or Scissor Truss. 770 30.0 1.0 26 Wall 1:Wood Frazee, 16"o.c. 704 19.0 0.0 39 Window 1:Vinyl Frame:Double Pane 60 0,360 22 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 770 21.0 1.0 32 Furnace 1:Forced Hot Air,78 AFUE ED resented in thus document is consistent with the building plans, COMPLIANCE STATEMENT': � �' � cp specifications,and other calcul 'tt rmit application. The proposed systems have been designed to meet-the Near York State Energy Cons ements. When a Registered Design Professional has stamped and signed this page,they are att r owledge,belief,and professional judgment,such plans or specifications are in e r Builder/Designer Date ` • ` FROM : TOWNSEND ASSOCIATES PHONE NO. 5184461995 May. 10 2004 02:37PM P3 i REScheck Inspection. Checklist New York.State Energy Conservation Construction Code RES checkSoftware Version 3.5 Rclease l d DATE:05/10/04 PROJECT TITLE:Dolor Addition-Herald Square Village,Lot 101 Bldg. ) Dot. ) Use l l J Ceilings: [ ] ) 1. Ceiling 1:Flat Ceiling or Scissor Truss, R-30.0 cavity+R-1.0 continuous insulation Comments: J Above-Grade''Walls: [ ] J 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments- Windows- 1. Window 1:Vinyl Fraxne:Double Pane,U-factor:0.360 For windows without labeled U-factors,desenbe.features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: -- Floors: [ ] 1. Floor 1:All-'Wood Joist/Tn%s:Over Unconditioned Space, 1t-21.0 cavity+R 1.0 continuous insulation Comments: „ l I Heating and Cooling Equipment: [ ] ) 1. Furnace 1:Forced Hot Air,78 AF'UE or higher Make and Model Number Air Leakage: [ ] l Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed_ [ ] ) Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"Clearance from combustible materials.If non-IC rated,the fixt"o must be installed with a J 3"clearance from insulation. l l Vapor Retarder: ( ] ) Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. I Materials Identification: [ ] I Materials and equipment must be installed in accordance with the manufacturer's installation iuzsttuctions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] ) Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. j ] ) Insulation R-values and glazing U factors must be clearly rwked on the building plans or specifications. I • Duct Insulation: [ ) ) Supply ducts in unconditioned attics or outside the building must be insulated to R-11_ [ ] ) Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] ) Supply ducts in unconditioned spaces must be insulated to R-11_ Retun ducts in unconditioned spaces(except basements)must be insulated to R-2. FROM TOWNSEND ASSOCIATES PHONE NO. 5184461995 May. 10 2004 02:38PM P4 [usulation is not required on return ducts in basements. I ( Duct Construction: [ ] I All.joints,seams,aad connections trust be securely fasterued with welds,gaskets,mastics [ (adhesives),mastic-plus-embedded-fabric:,or tapes. Duct tape is not permitted_ Exception:Continuously welded and locking-type longitudinal joints and seams on ducts J operating at less than 2 in w.g.(500 Pa). [ ] I Ducts shall be supported every 10 feet or its accordance with the manufacturer's instructions_ [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] ( Air filters are required in the return air system. I ] I The HVAC system miist provide a means for balancing air and water systems. I I Temperature Controls: [ ] I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space J temperature set point of the largest zone. I I Electric Systems: [ ] I Separate electric meters are required for each dwelling unit. J f Fireplaces: [ ] J Fireplaces must be installed with tight fitting non-combustible fireplace doors, [ ] I Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction J provisions of the Building Code of New York State ,the Residamial Code of New York Siale or the New York City Building Code ,as applicable. J Service Water Heating: [ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the J water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1, I J Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. I ` Swimming Pools: [ ] ( All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non.-depletable sources. Pool pumps require a time clock. I J Heating and Cooling Piping Insulation- [ ] I HVAC piping conveying fluids above 105 'F or chilled fluids below 55 °F must be insulated to the I levels in Table 2. FROM TOWNSEND.ASSOCIATES PHONE NO. 5184461995 May. 10 2004 02:38PM P5 Table 1: Minimuna Insulation Thickness for Circulating 1Yot Water pipes. lusulation Thiclaaess in Incheg by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts. Temperature(P) UP to 1„ 1 p to 1.25" 1.5.'to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC,Pipes. Pluid"Temp. Insulation Thickness in Inches by Pipe Sizes Piping Systern Types Range F 2"Run6uts I"and Less 1.25"to 2" 2.5"to 4" !Heating Systems Low Pressure/Temperature 201-250 110 1.5 1.5 2.0 Low Temperature 120-200 0,5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 Lo 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 MOTES TO FIELD (Btuldiug Department Use Only) f E w ,N ti ti S%D. LOT 35 LOT 100 nI� M NOTES' 1. UNDERGROUND UTILITIES SHOWN HEREON BASED ON UTILITY EVIDENCE S82 STOCKADE FENCE e02siQME VISIBLE AT GROUND SURFACE AND RECORD DRAWINGS AND ARE SUBJECT O To FIELD VERIFICATION BY EXCAVATION. UTILITIES SHOWN DO NOT LC'T 1 O1 J PURPORT To CONSTITUTE OR REPRESENT ALL UTILITIES LOCATED UPON OR ZO� ADJACENT To THE SURVEYED PREMISES. AREA 20,000 SQ.FT. 2. THE OFFSETS OR DIMENSIONS SHOWN HEREON. FROM THE PROPERTY LINES 42 5 _ TO THE STRUCTURES. ARE FOR A SPECIFIC PURPOSE AND USE: THEREFORE, �� E>� m D THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO 2 STORY GUIDE THE ERECTION OF FENCES, ADDITIONAL STRUCTURES, OR ANY OTHER 04 WOW t>� ��', � LOT 36 o�c IMPROVEMENT. Irn m PRIP050 AooON or Q 3. EASEMENTS AND/OR SUBSURFACE STRUCTURES RECORDED OR U cARAcc O O UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON AKT f THE PREMISES AT THE TIME OF THE SURVEY. POOL W mew �' 4. SUBJECT TO ALL RIGHTS. EASEMENTS, COVENANTS AND RESTRICTIONS OF z RECORD. Y 3 'Oo� 4 CHAIN LINK FENCE 200.00 �JV�JV 5. SUBJECT TO ANY STATE OF FACTS AN UP—TO—DATE ABSTRACT OF TITLE -'� N8202'10"W LOT 107 WOULD DISCLOSE. LOT 102 1 6. TAX MAP DESIGNATION: 308.10-1-44 APR 2' TOnt4 OFI0` of N R:\field\nrdhouse.dwg 04/22/2004 08:15:22 AM EDT O Copyright Date Record of Work Appr. Pine west Plaza, Building IA s o 04-22-04 C CO I ht 2002 11 8 Ex*r, Unauthorized iteration or Vollmer Associates LLP wasnlnAba Avenue 205-5 10 addition to this map h a Albany, NY 122oS551D violation at eecYKxr 72�. � 1� = 40' MAP SHOWING Engineers, Architects, Yo rk St tee"Educatioon a: Landscape Architects, LOT 101 - 6 WAYNE COURT Planners, Surveyors ASSOCIATES LLP only copies map bearing the original 4 By HERM.D U E All rights reserved. n3tneers ot this m� bear% an o, original s ature and the �F `^C Architects emboasad of the Unauthorized duplication is _ preparer eh°m`Plbe�ar,eidered (�q rawn By. mrd �'rjAj, SUMPY j�N ancia violation of applicable laws. Sur eyors pe A:chd cs to be true and valid copies Tax 518.452.9234 Chk. B MRD Town of Queensbur Warren Count New York . Planners Fax:518.452.9234 NARK R. DElOR P.LS. Y y y