Loading...
TAB Report - 365 Bay RoadNortheastern Air Quality, Inc. P.O. Box 3271 Albany, New York 12203 (518) 857-3641 HVAC SYSTEMS TESTING: Project:365 Bay Road Bay Road Liquors Location:Queensbury, New York Architect:Rucinski Hall Architecture Glens Fdalls, New York Engineer: Piping: Sheet Metal:Monahan & Every Plumbing and Heating Queensbury, New York Date:1/28/212 Prepared by:R. Kelley RKelley@NortheasternAirQuality.com Air Balance Report CERTIFICATION PROJECT: ADDRESS: TESTING AND BALANCING FIRM: CERTIFIED BY:DATE:1/28/212 SIGNATURE: Robert V. Kelley #REF! Queensbury, New York THE DATA PRESENTED IN THIS REPORT IS AN EXACT RECORD OF SYSTEM PERFORMANCE AND WAS OBTAINED IN ACCORDANCE WITH NEBB STANDARD PROCEDURES. ANY VARIANCES FROM DESIGNED QUANTITIES WHICH EXCEEDS NEBB TOLERANCES ARE NOTED THROUGHOUT THIS REPORT. THE AIR DISTRIBUTION SYSTEMS HAVE BEEN TESTED & BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH NEBB ''PROCEDURAL STANDARDS FOR TESTING AND BALANCING OF ENVIRONMENTAL SYSTEM'' AND THE PROJECT SPECIFICATIONS. Northeastern Air Quality, Inc. #3159 Page 2 Northeastern Air Quality, Inc. P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 PROJECT: THE FOLLOWING IS A LIST OF STANDARD ABBREVIATIONS WHICH MAY APPEAR IN THIS REPORT: MEANING MEANING A AMPS or AMPERAGE NL NOT LISTED ACH AIR CHANGES PER HOUR NOM NOMINAL AD ACCESS DOOR NOM EFFY NOMINAL EFFICIENCY ADJ ADJUSTABLE NR NOT REQUIRED Ak KINETIC (EFFECTIVE FREE) AREA NS NOT SPECIFIED BG BLAST GATE OBD OPPOSED BLADE DAMPER BHP BRAKE HORSEPOWER OED OPEN END DUCT CALC CALCULATED PF POWER FACTOR CALIBR CALIBRATION or CALIBRATED PH PHASE CD CEILING DIFFUSER Ps STATIC PRESSURE CF CUBIC FEET Pt TOTAL PRESSURE CFM CUBIC FEET PER MINUTE Pv VELOCITY PRESSURE cL CENTERLINE RG RETURN GRILLE CLG CEILING RPM REVOLUTIONS PER MINUTE CR CEILING REGISTER RR RETURN REGISTER CS CIRCUIT SETTER SBD SINGLE BLADE DAMPER CSD CEILING SUPPLY DIFFUSER SD SMOKE CONTROL DAMPER DD DIRECT DRIVE SF SERVICE FACTOR DDC DIRECT DIGITAL CONTROL SMC SHEET METAL CONTRACTOR DISC DISCONNECT SWITCH SPS STATIC PRESSURE SENSOR DISCH DISCHARGE SR SUPPLY REGISTER DPR DAMPER TC TEMPERATURE CONTROL DR PRESSURE DIFFERENTIAL TCC TEMPERATURE CONTROL CONTRACTOR EC END CAP TCD TEMPERATURE CONTROL DAMPER ER EXHAUST REGISTER TP THERMALLY PROTECTED FL BHP BRAKE HORSEPOWER @ FULL LOAD AMPS TRAV DUCT TRAVERSE FLA FULL LOAD AMPS V VOLTS or VOLTAGE FTR FINNED TUBE RADIATION VAR VARIABLE GPM GALLONS PER MINUTE VBD V-BELT DRIVE HP HORSEPOWER VD VOLUME DAMPER LD LINEAR DIFFUSER VEL VELOCITY LF LINEAR FEET (NOMINAL)W WATTS or WATTAGE NA NOT ACCESSIBLE WG WALL GRILLE ND NO DAMPER WMS WIRE MESH SCREEN NDRG NON-DUCTED RETURN GRILLE WR WALL REGISTER NG NO GAUGE ZD ZONE DAMPER NI NOT INSTALLED NIC NOT IN CONTRACT ABBREVIATIONS #REF! ABBREVIATION ABBREVIATION Page 3 Northeastern Air Quality, Inc. P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 1/28/2021 MOTOR NAME-RPM PLATE VOLTS HERTZ 115 60 115 60 DATA EXT. STATIC PRESSURE VOLTS AMPS BHP (calc.)0.30 T3 (3 Ph only) F.L.A.ACTUAL 0.25 T1 6.4 2.7 6.4 3.2 T2 (3 Ph only) T1 - T3 (3 Ph only) T1 - T2 115 122 115 122 T2 - T3 (3 Ph only) SYSTEM:AHU-1 AHU-2 LOCATION:Meh. Closet Meh. Closet MODEL:TM9E060B12MP12A TM9E080B12MP12A SERIAL NUMBER:W2H0094978 W2H00132211 SERVICE:North/East Side Soth/West MANUFACTURER:York York PROJECT:#REF! TESTED BY:R. Kelley DATE: AIR MOVEMENT EQUIPMENT TEST SHEET STYLE FRAME -DD -DD DATE TESTED:1/28/2021 1/28/2021 MANUFACTURER Gentech Gentech 1 1 FL AMPS S.F.6.4 -6.4 - -- Direct Drive Direct Drive HP 1/2 1050 1/2 1050 PHASE P.F.NOM EFFY ---- TEST DATA DESIGN ACTUAL DESIGN ACTUAL Direct Drive Direct Drive Direct Drive Direct Drive Direct Drive CALCULATED (P.F. x NOM EFFY) * MOTOR SHEAVE STARTER HEATER ELEMENTS 0.57 0.57 SHEAVE cL DISTANCE BELTS FAN SHEAVE FAN RPM Direct Drive NS 851 TOTAL CFM - FAN NS 876 NS 1153 -0.35 TOTAL CFM - OUTLETS NS 862 NS 1121 RETURN AIR CFM NS 841 0.43 NL 0.13 OUTSIDE AIR CFM NS -NS 222 TOTAL - DISCHARGE NL 0.17 NL 0.22 INLET NL 0.26 REMARKS: * NOTE: If P.F. or NOM EFFY are NL, (P.F. x NOM EFFY) = 746Hp/(VAX), where X = 1 if 1 Ph, and 1.73 if 3 Ph Page 4 Northeastern Air Quality, Inc. P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 1/28/2021 MOTOR NAME-RPM PLATE VOLTS HERTZ 115 60 115 60 DATA EXT. STATIC PRESSURE VOLTS AMPS BHP (calc.) REMARKS: Direct Drive Direct Drive Direct Drive Direct Drive 0.06 PROJECT:365 Bay Road TESTED BY:R. Kelley DATE: SYSTEM:ERV1 LOCATION:Storage Room SERVICE:AHU-2 MANUFACTURER:Lifebreath MODEL:267Max SERIAL NUMBER:10202008904 DATE TESTED:1/28/2021 FAN DATA SUPPLY RETURN MANUFACTURER STYLE FRAME -DD -DD HP PHASE 1 1 FL AMPS S.F.4.5 NS 4.5 NS P.F.NOM EFFY NS NS NS NS calculated (P.F. x NOM EFFY) *0.72 0.72 STARTER HEATER ELEMENTS - MOTOR SHEAVE Direct Drive Direct Drive FAN SHEAVE Direct Drive Direct Drive BELTS SHEAVE cL DISTANCE TEST DATA DESIGN ACTUAL DESIGN ACTUAL TOTAL CFM - FANS TOTAL CFM - OUTLETS 180 184 180 178 RETURN AIR CFM OUTSIDE AIR CFM DISCHARGE NL NL INLET NL NL TOTAL FAN RPM T1 - T2 115 122 115 122 T2 - T3 (3 Ph only) T1 - T3 (3 Ph only) T1 5 5 T2 (3 Ph only) T3 (3 Ph only) F.L.A.ACTUAL 0.06 * NOTE: If P.F. or NOM EFFY are NL, (P.F. x NOM EFFY) = 746Hp/(VAX), where X = 1 if 1 Ph, and 1.73 if 3 Ph ENERGY RECOVERY VENTILATOR TEST SHEET Page 5 Northeastern Air Quality, Inc. P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 MOTOR NAME-RPM PLATE VOLTS HERTZ DATA EXT. STATIC PRESSURE VOLTS AMPS BHP (calc.) REMARKS: SYSTEM: LOCATION: SERVICE: MANUFACTURER: MODEL: SERIAL NUMBER: DATE TESTED: FAN DATA MANUFACTURER STYLE FRAME HP PHASE FL AMPS S.F. P.F.NOM EFFY calculated (P.F. x NOM EFFY) * STARTER HEATER ELEMENTS MOTOR SHEAVE FAN SHEAVE BELTS SHEAVE cL DISTANCE TEST DATA TOTAL CFM - FANS TOTAL CFM - OUTLETS RETURN AIR CFM OUTSIDE AIR CFM DISCHARGE INLET TOTAL FAN RPM T1 - T2 T2 - T3 (3 Ph only) T1 - T3 (3 Ph only) T1 T2 (3 Ph only) T3 (3 Ph only) F.L.A.ACTUAL * NOTE: If P.F. or NOM EFFY are NL, (P.F. x NOM EFFY) = 746Hp/(VAX), where X = 1 if 1 Ph, and 1.73 if 3 Ph 1/28/2021 PROJECT:365 Bay Road TESTED BY:DATE: SUPPLY RETURN DESIGN ACTUAL DESIGN ACTUAL NLNL NL NL ENERGY RECOVERY VENTILATOR TEST SHEET Page 6 Northeastern Air Quality, Inc. P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 MOTOR NAME-RPM PLATE VOLTS HERTZ DATA EXT. STATIC PRESSURE VOLTS AMPS BHP (calc.) REMARKS: SYSTEM: LOCATION: SERVICE: MANUFACTURER: MODEL: SERIAL NUMBER: DATE TESTED: FAN DATA MANUFACTURER STYLE FRAME HP PHASE FL AMPS S.F. P.F.NOM EFFY calculated (P.F. x NOM EFFY) * STARTER HEATER ELEMENTS MOTOR SHEAVE FAN SHEAVE BELTS SHEAVE cL DISTANCE TEST DATA TOTAL CFM - FANS TOTAL CFM - OUTLETS RETURN AIR CFM OUTSIDE AIR CFM DISCHARGE INLET TOTAL FAN RPM T1 - T2 T2 - T3 (3 Ph only) T1 - T3 (3 Ph only) T1 T2 (3 Ph only) T3 (3 Ph only) F.L.A.ACTUAL * NOTE: If P.F. or NOM EFFY are NL, (P.F. x NOM EFFY) = 746Hp/(VAX), where X = 1 if 1 Ph, and 1.73 if 3 Ph 1/28/2021 PROJECT:365 Bay Road TESTED BY:DATE: SUPPLY RETURN DESIGN ACTUAL DESIGN ACTUAL NL NL NL NL ENERGY RECOVERY VENTILATOR TEST SHEET Page 7 Northeastern Air Quality, Inc. P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 MOTOR NAME-RPM PLATE VOLTS HERTZ DATA EXT. STATIC PRESSURE VOLTS AMPS BHP (calc.) REMARKS: SYSTEM: LOCATION: SERVICE: MANUFACTURER: MODEL: SERIAL NUMBER: DATE TESTED: FAN DATA MANUFACTURER STYLE FRAME HP PHASE FL AMPS S.F. P.F.NOM EFFY calculated (P.F. x NOM EFFY) * STARTER HEATER ELEMENTS MOTOR SHEAVE FAN SHEAVE BELTS SHEAVE cL DISTANCE TEST DATA TOTAL CFM - FANS TOTAL CFM - OUTLETS RETURN AIR CFM OUTSIDE AIR CFM DISCHARGE INLET TOTAL FAN RPM T1 - T2 T2 - T3 (3 Ph only) T1 - T3 (3 Ph only) T1 T2 (3 Ph only) T3 (3 Ph only) F.L.A.ACTUAL * NOTE: If P.F. or NOM EFFY are NL, (P.F. x NOM EFFY) = 746Hp/(VAX), where X = 1 if 1 Ph, and 1.73 if 3 Ph 1/28/2021 PROJECT:365 Bay Road TESTED BY:DATE: SUPPLY RETURN DESIGN ACTUAL DESIGN ACTUAL NL NL NL NL ENERGY RECOVERY VENTILATOR TEST SHEET Page 8 Northeastern Air Quality, Inc. P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 MOTOR NAME-RPM PLATE VOLTS HERTZ DATA EXT. STATIC PRESSURE VOLTS AMPS BHP (calc.) REMARKS: SYSTEM: LOCATION: SERVICE: MANUFACTURER: MODEL: SERIAL NUMBER: DATE TESTED: FAN DATA MANUFACTURER STYLE FRAME HP PHASE FL AMPS S.F. P.F.NOM EFFY calculated (P.F. x NOM EFFY) * STARTER HEATER ELEMENTS MOTOR SHEAVE FAN SHEAVE BELTS SHEAVE cL DISTANCE TEST DATA TOTAL CFM - FANS TOTAL CFM - OUTLETS RETURN AIR CFM OUTSIDE AIR CFM DISCHARGE INLET TOTAL FAN RPM T1 - T2 T2 - T3 (3 Ph only) T1 - T3 (3 Ph only) T1 T2 (3 Ph only) T3 (3 Ph only) F.L.A.ACTUAL * NOTE: If P.F. or NOM EFFY are NL, (P.F. x NOM EFFY) = 746Hp/(VAX), where X = 1 if 1 Ph, and 1.73 if 3 Ph 1/28/2021 PROJECT:365 Bay Road TESTED BY:DATE: SUPPLY RETURN DESIGN ACTUAL DESIGN ACTUAL NL NL NL NL ENERGY RECOVERY VENTILATOR TEST SHEET Page 9 Northeastern Air Quality, Inc.GRILLE, REGISTER & DIFFUSER REPORT P.O. Box 3271, Albany, NY 12203-0271 PROJECT: (518) 857-3641 TESTED BY:DATE: REMARKS: DESIGN INITIAL INTERMEDIATE FINAL % OF NO.LOCATION SIZE MODEL Ak VEL CFM VEL CFM VEL CFM VEL CFM DES DATE REMARKS AHU-1 1 Retail 14" x 6"Hood 48 Hood 48 1/28/21 2 Retail 14" x 6"Hood 75 Hood 75 1/28/21 3 Retail 14" x 6"Hood 96 Hood 96 1/28/21 4 Retail 14" x 6"Hood 101 Hood 101 1/28/21 5 Retail 14" x 6"Hood 48 Hood 48 1/28/21 6 Retail 14" x 6"Hood 101 Hood 101 1/28/21 7 Retail 14" x 6"Hood 112 Hood 112 1/28/21 8 Retail 14" x 6"Hood 88 Hood 88 1/28/21 9 Retail 14" x 6"Hood 128 Hood 128 1/28/21 10 Retail 14" x 6"Hood 65 Hood 65 1/28/21 Total 862 862 1/28/21 Return 11 Floor 30" x 8"Hood 419 Hood 419 1/28/21 12 Wall 30" x 8"Hood 422 Hood 422 1/28/21 Total 841 841 1/28/21 AHU-2 13 Retail 12" x 8"Hood 134 Hood 134 1/28/21 14 Retail 12" x 8"Hood 133 Hood 133 1/28/21 15 Retail 12" x 8"Hood 118 Hood 118 1/28/21 16 Rear Entrance 12" x 8"Hood 122 Hood 122 1/28/21 17 Retail 12" x 8"Hood 115 Hood 115 1/28/21 18 Office 12" x 8"Hood 154 Hood 154 1/28/21 19 Storage 12" x 8"Hood 135 Hood 135 1/28/21 20 Bathroom 12" x 8"Hood 87 Hood 87 1/28/21 21 Storage 12" x 8"Hood 123 Hood 123 1/28/21 Total 1,121 1,121 1/28/21 R. Kelley 1/28/212 365 Bay Road Page 10 Northeastern Air Quality, Inc.GRILLE, REGISTER & DIFFUSER REPORT P.O. Box 3271, Albany, NY 12203-0271 PROJECT: (518) 857-3641 TESTED BY:DATE: REMARKS: DESIGN INITIAL INTERMEDIATE FINAL % OF NO.LOCATION SIZE MODEL Ak VEL CFM VEL CFM VEL CFM VEL CFM DES DATE REMARKS R. Kelley 1/28/212 365 Bay Road Return 22 Retail Sales 26" x 8"Hood 368 Hood 368 1/28/21 23 Retail Sales 26" x 8"Hood 265 Hood 265 1/28/21 24 Retail Sales 26" x 8"Hood 218 Hood 218 1/28/21 Total 851 851 1/28/21 ERV 25 Supply 6" R 0.2 NS 921 184 921 181 1/28/21 26 Exhaust 6" R 0.2 NS 942 178 942 185 1/28/21 Page 11 Northeastern Air Quality, Inc.Duct Traverse Totals P.O. Box 3271, Albany, NY 12203-0271 PROJECT: (518) 857-3641 DATE: System Area % OF NO.Zone or Branch Sq. Ft.VEL CFM VEL CFM SP VEL CFM SP DES DATE T-1 AHU-1 Supply 8''x 20''1.11 NS 788 876 788 876 0.17 1/28/21 T-2 AHU-2 Supply 8''x 20''1.11 NS 1,038 1,153 1,038 1,153 0.22 1/28/21 ERV T-3 Supply 6''Rnd 0.20 1,121 220 936 184 1,106 217 0.10 99%1/28/21 T-4 Return 6''Rnd 0.20 1,121 220 908 178 1,131 222 0.11 101%1/28/21 Duct Size Low Speed High Speed #REF! 1/28/2021 DESIGN REQUIRMENT INITIAL FINAL