Loading...
2004-265 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20040265 Date Issued: Wednesday, December 15, 2004 This is to certify that work requested to be done as shown by Permit Number P2004-0265 has been completed. Tax Map Number: 523400-288-000-0001-086-013-0000 Location: 49 BUCKBEE Rd Owner: MARK &AMY CRONIN Applicant: NIARK &AMY CRONIN This structure may be occupied as a: By Order of Town Board Garage - 2 Cars Attached TOWN OF QUEENSBURY Single Family Dwelling . Director of Building&Code Enforcement y TOWN OF. QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518),761-8256 BUILDING PERMIT Permit Number: P20040265 Application Number: A20040265 Tax Map No: 523400-288-000-0001-08.6-013-0000 Permission is hereby granted to: MARK & AMY CRnN1N For property located at: 49 BUCKBEE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tyne of Construction Value Owner Address: MARK& AMY CRONIN Garage-2 Cars Attached 14.GROVE Ave HUDSON FALLS,NY 12839-0000 Total Valumtly Dwelling $130, 00. 0 $130,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2004-265 Lot 1 C, House No. 49 Buckbee Road, Subdivision Name: Hunt Lake Land Holding Co., Inc. Recreation Fee is Paid ($500). 1,800 SQ FT SINGLE FAMILY DWELLING $279.90 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,May 07, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T wn of uee ri ay 07, 2004 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement ENERGY CODE COWLL ,NCE APPLICATION S TOWN OF UEENSBURY 9000 HEATING DEGREE WARREN rrH f � � �004 r�il'ZQ U�EVs8u�Y Compliance Methods:Part 5 -Acceptable Practice Method—1&2 Family Dwellings(Drily) CODE Part 6*-Thermal Rating—Component trade Offs 1&2 Family Dwelling; Multi-Family Dwellings(3 Stories or less) Part 4*-Design by Component Performance,Commercial Buildings-Hi Rise Residential *Requires submission of worksheets APPLICANT'S NAME: PROPER LOC TION: / IH%rL � -C11-,b. V.9 � - I ec Q Qcae��� PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE: 1. Gross Floor Area 0 square feet 2. Type of heat- Electric _Oil Gas Other 3. Is building mechanically cooled? yes_K_No I 4. Percentage of area of windows and doors Over 17% 'x/ .Under 17% 5. R VALUES FOR INSULATION GIVEN BELOW MUST CORRESPOND TO R VALUES AS SHOWN ON PLANS SUBMITTED: a: Roof R 3 S b. Exterior walls - R_f _ C. Glazed areas R d. Exterior doors R e. Floors over unheated spaces R� f. Edge of slab on grade(heated building) R /V 4 g. Basement/cellar yndls(above grade) R� h. Basement/cellar walls(below grade) R 1% i. Heating/cooling-ducts-piping in unheated space R Al A 6. Service(domestic)hot water heating device Conforms to minimum efficiency per code >r--Yes No TEMPERATURE CONTROL MAXIMUM SETTING 140—WILL NOT BE EXEEDED Apnet's Signature Date Phone Number INSPECTOR'S REMARKS: Application for Permit Septic Disposal System Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256 . 1. OWNER INFORMATION: } ............................:.....................Offi.........:ce.........U........s...............,,,. 7 ....,...............,..........., `,. [ /�/q c K n ! - e 4 Location of installation: � e 'P5eX e�;'. 'i&N Tax Map No. / ...., l,0 ... . ......... ......................................... Owner's Name: k ,�a Tny�/wl ..,....................................... ... ... Address: 7 o v v�� I,DI1yG,�rVD c00�1, 2. INSTALLER'S NAME : G V" PHONE NO. 2 91— 0 VFf 3. RESIDENCE INFORMATION: (circle year of dwelling,indicate#bedroom(s) and multiply#of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of Bedrooms x Computation = Total Daily Flow 1980 or older x 150 gal/bdrm = 1980—1991 x 130 gal/bdrm = 1991—present x 10 gal/bdrm = ?Z Garbage Grinder Installed yes_ / no Spa or Hot Tub Installed yes, ./ no 4.' PARCEL INFORMATION:. (circle applicable information&indicate measurements) Ton-oagphy Soil Nature Ground Water Bedrock or Lmpervious Material Domestic Water SgRply lat sand at what depth at what depth municipal Rolling am o Meet 7o feet ell - Steep slope clay z well;water supply slope' other from any septic-system depth: absorption is ,)J oft. other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: ''S minute per inch 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or VA*Ipool Tub. Septic Tank: 025 Z) gallon(min.size 1,000 gal.) Tile Field: each trench ft, Total System Length: Seepage Pit(s): number of _ size of each: ft. by ft. Size of Stone to be used: # / depth or thickness feet Bed System Size: z Alternative System: length and/or size 6. HOLDING TANK SYSTEM: (if required) , Number of tanks: -I Size of each: _-gallons i TOTAL Capacity: ---gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material-fact or circumstance known by or on behalf of an applicant; shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. ALO Signature of responsible person Date 1u7J , . ;'l'cnv'Ii`Ur ��LtVt"11g131it-y ' so.wem and 'HCWi1ne I)gvosal t:l)IIj)irt- App-ondix C. / ll-it)M"'i ION FIELD EI D 's mom f ONp -. 1.�.� y'I�LI. IN )l�lT1�'rt• � �Ix�uT. chi,►tC; �.... �—'�)LUt . . --w--- .� .. i I A-1IY. of" U11111 A�Y�RPttC:t) r ' IMMI1 .w,r r. ,••w•1 ?, S1rTNA.TURE &INFORMS+.'TION FM'USr UN;S sLrw r>✓gl%ovj,'4 �V•VYY e ' Building Permit Application Town of Queensbury—Dept of Community Development,742 Bay Road,Quednsbury,NY (518)761-8256 - A permit must be obtained before beginning con. � 7NI(ZP1 ile No.No inspection will be made until applicant has received a $- valid building permit. All applicants' spaces on this. [y;H`� Paid $application mustbe completed and must appear on the d By: application form. TOWN OF OUEn BUILDING A�1ID C� E Applicant: ft c t o_ -(v e j C o.-,t Y.c a e, Owner: k a�,cn L s Address: (n� o Address: 6 v a t-4 toJ c, e, i(. / A"17 So -A),L I R3� Phone#(- J j) -. 6�,4 6 " Phone#(fig)2YI- dq,�,E ; W- 0 79/- 049? Property Location: Lot Number: / House Number . / L% L t JOA Subdivision Name: �. Tax Map Number: VYNew Building: resid ce ommercial 'Estimated Market Value of Construction: $ 0 600 a Addition: residence/'eemmoreial 1f an Addition,what will use of new'addition be? a Alteration: residence/ commercial O No change to exterior size: residence/com21 O Other work(describe Check OccnpancyInformation 1' Floor 2° Floor Other floor Total Below sq.ft. sq ft. sq.ft. Square Feet d' Single famil dwelling )d'0 U J00.0 p a Two family dwollin a Townhouse 1 o Multifamily dwelling #of units o Office , a Mercantile a Manufacturin a 1 car detached garage D 2 car detached garage 0 3 car detached garage a 1 car attached garage 2 car attached garage !x ► 3 5 S a a Storage building- commercial a Storage building- residential �3 a Other What is the proposed height of the structure feet inches Will any second-hand or ungraded lumber be used? If so,for what? /V o Type of Heating System: electric/ oil / gas/wood / orced t a' baseboard/other: Number of.P'tmulaces to be installed Number of Woodstav s to be installed " List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder C�. - a 7 9/-o i k Plumber Mason Electrician Declarations please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together_with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Uwe shall submit,prior to a certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an pis B yat Survey by a licensed surveyor;drawn to scale,showing actual location of all new construction. Signature:___ �( owner,owner's agent,architect,contractor Queensbuly Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/ m D part:47 3am/pm Date Inspection request received: Inspector's Initials:3 NAME: C R /J PERMIT#: J LOCATION: (?ayC_j� �—C� �� DATE: TYPE OF STRUCTURE: _ Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in. or more r.stairs, decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum ''/2" Gypsum Grade away from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans,if no window /]�Iumbing fixtures Foundation insulation Floor truss,truss, draft stopping finished basement 1,000 sf Emerge c egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Gara e fire roofing/3/4 hour fire door/door closer Duct work Sealed nronerlv Gas Lo s in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft. vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer e t.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/® Temporary/Permanent] L:\PamW\Building&Codes\Insuection Forms\Res. Final Inst). form 2.docLast printed 2/12/04 Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: Z J"'j 4 NAME: C-R d AJ(/►� LOCATION: PERMIT#: Final Survey Plot Plan AlDvroved Denied The attached final survey has been received by the Dept. of Community Development. Upon review the survey has been: Craig Br , Z 'ng Administrator Notes: L:\.SueHemingway\Building.Codes.Inspection.FORMS\Fina1 Survey Zoning Administrator.doc DEED REFERENCE: HUNT LAKE LAND HOLDING COMPANY, INC. TO LEGEND MARK D. & AMY H. CRONIN DATED MARCH 21, 2002002 BOOK 1257 PAGE 142 o I.R.F. IRON ROD FOUND o I.P.F. IRON PIPE FOUND o I.R.S. IRON ROD SET mi UTILITY POLE 000o STONE WALL - - - BARBED WIRE FENCE MAP REFERENCE: e POINT W.F.P. WOOD FENCE POST MAP ENTITLED "MAP OF A SURVEY MADE FOR HUNT —ohw OVERHEAD WIRES �� LAKE LAND HOLDING COMPANY, INC. PREPARED BY DAVID J. BOLSTER LLS LAST REVISED OCTOBER 31, 2001 FILED IN PLAT 8 SLIDE No. 184 IN THE OFFICE FBI THE WARREN COUNTY CLERK 04 S64 26'30"E 10.36' S65 49'00"E 61.68' LOT 1A z �"?' S7870'30"E �s 36.08 V: m 0 �n 0• zo CV /� �9• i O NOTE• ? 70 4 UNDERGROUND• U77LI77ES 3 _ 0 y QD' � 30' wide driveway easement •:i°' w for the benefit of Lot 1D k ' LOT !$ rA ¢� Lands n/f of ^• ' Randall Lockhart Book 1248 Page 22 { shed �o transformer 0 LOT IC ` 5.04'1-ACREL') i LOT ID Lands n/f of aw Kevin Benway hry Book 1250 Page 84 drilled •': ry well moo,. y • �—130 4' house under. constructtgn N 170.00, N8323'30"W 240 2.2' NOTES: N8258.00"W 1) THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF AN ABSTRACT OF TITLE AND IS Lands n/f of MAP OF LOT 1 C MADE FOR MADE FOR THEREFORE SUBJECT TO ANY EASEMENTS, Michael & Amelia Fortounas COVENANTS OR RESTRICTIONS OF RECORD Book 874 Page 43 ` rj LANDI'���''� ANY WOULD AD DISCLOSE.F FACTS SUCH DOCUMENT �5.1� '!`O�'y. MARK D. �c AMY H. UIr"ONIN L 2) UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A VIOLATION OF SECTION 7209, SUB—DIVISION 2, OF THE TOWN OF QUEENSBURY, COUNTY OF WARREN, STATE OF NEW YORK NEW YORK STATE EDUCATION LAW. ` ���`yOQ' DA VID J. B OL S TER 3) ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY ''aFOF LICENSED LAND SURVEYOR MARKED WITH AN ORIGINAL OF THE LAND SURVEYORS SEAL SHALL BE CONSIDERED TO BE VALID TRUE COPIES. 342 MAIN STREET, HUDSON FALLS, NEW YORK 12839 4) HIGHWAY BOUNDARIES SHOWN ARE ASSUMED 25' FROM THE DAVID J. BOLSTER, LLS DATE: AUGUST 13, 2004 SCALE: 1" = 100' N.Y.S. LIC. NO. 49534 CENTER OF THE EXISTING ROAD SURFACE. DWG. N0. 04-164 C DATE SEALED /3�Q QUEENSBURY 288-1-86.13 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/pm Depart: am/pm Date Inspection request'received: _ Inspector's Initials: k4o NAME: .���. PERMIT# 0 Ct �p LOCATION: r-,. DATE: TYPE OF STRUCTURE: _ \ Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs, decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Vi Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %Z" Gypsum Grade away from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18" above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area /7z Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight 2— Safety glazing/Window in stairwells safety lazin Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures _ n Foundation insulation �Oti„`�(,� �� 1A6 04 Floor truss, draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/4 hour fire door/door closer L Duct work Sealed properly lC�ig�— �v e7 Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 4" ccess, 1 s . ft,150 s . ft. vents �✓� ���� w Sh j �,� Building No./Addr ss v sibjd from road Final Electrical "l 999 Site Plan /VarianceOgi' e D Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res, Final Insi). form 2.docLast printed 2/12/04 l I Septic Inspection Report Office No. (518) 761-8256 Date Inspection reque e v �l `0-'- 6 Queensbury Building&Code Enforcement Arrive: .h a p a pm� 742 Bay Rd., Queensbury,NY 12804 Inspector's Initial . NAME: Uc�t�� b"'l. L E NO.: LOCATION: SPECT ON: j j a- d54 RECHECK: Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. J Well separation distance ft. Other wells: ft. Absorption Field: Total length Length of each trench Depth of trenchesf2 ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank .1,° =.�- Tank to Distribution Box Distribution Boxx iel Pit �� � tiC�t„E' ��ew D OpeningSealed Y Partial Location/Separations Foundation to tank -r J ft. Foundation to absorption 771 Separation of Pits Conforms as per Plot Plan Y N Location of System on Property: Front Rear Left Side Right Side Middle F or nt`M�ddle Rear System Use Status:/ Approved r' Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved Town of Queensbury Fire Marshal 742 Say Road Queensbury,NY 12804 761-8205/761-8206 fax 7454437 Factory Built Wood Burning Fireplace/Stove Inspection Report Notices New York State requires that all UI.Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. Permit# Schedule Inspection O III% Time _ pm anytime Inspector Name A0Nr�i Address C� 9�G�FS%'4 1C�7 hough In Final Appliance Manufacturer, �-�ti�t:i; }�� °CG j c_v Model# NJ u� i.h St i�- Masonry Chimney Factory Built Chimney Flue Size Double Wall Triple Wall Insulated^ Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Safety Strip Installation (fireplaces only) lam_ tJ Firestop(s) Vertical Chase Wall Penetration Chimney Clearances to Combustibles Chimney Termination 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Combustion Air Hearth Extension Mantel (height above f/p opening) Fireplace Doors /Screen (required) f�• White—Building(Dept. yello —Cus user Pink—Fire Marshal Town of Queeansbury Fire Marshal 742 Bay Road � Queensbury,NY 12804 f 761-8205/761-8206 fax 745-4437 Factory Built Wood Burning Fir�place/Stove Inspection Report Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's / instructions or specifications is allowed. hermit# ��- �> '` I !1� Schedule Inspection l L Tiine�pan anytime Inspector__ Name I21 V 0 Ci-!+ r— Address `'i I hough In x Final Appliance Manufacturer Model t-\<h 4 -' Co�'�.— \J�V..;;5,O 14 1 r Masonry Chimney Factory Built Chimney Flue Size Double Wall' Triple Wall Insulated Yes No N/A Comments Floor Protection 9 Clearances to Combustibles (all sides) �i � � � 1 `Xc: Safety Strip Installation (fireplaces only) Firestop(s) Vertical chase Wall n W a Penetration Chimney Clearances to Combustibles Chimney Termination 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Combustion Air .Hearth Extension Olut w10`l C'�' 1� Mantel(height above Vp opening) Fireplace Doors/Screen (required) White—Building Dept. Ycllo —CUB aver Pink—Fire Manhal 1 Septic Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am��- De rt. am/pm 742 Bay Rd., Queensbury,NY 1,2804 Inspector's Initials: s-�-- NAME: —` PERMIT NO.: O LOCATION: INSPECT ON: — RECHECK: Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. �� �N 1,7C�1e L)RI G— Well separation distance ft. cc Other wells: ft. w J� Absorption Field: Total length ft, Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Si T e , Building to tank Tank to Distribution Box Distribution Box ield 1 Pit Opening Seale Y INI Partial Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status- Approved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved L:\SueHemingway\Building.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: , Queensbury Building& Code Enforcement Arrive: am/p Deport: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: � NAME: PERMIT #: L(`� LOCATION: INSPECT ON: ' — 9-0 L4 TYPE OF STR T Y N N/A PVC: R-1, R-2, R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/ Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min. Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test / Drain and Vents 5 PSI or 10 feet above highest ' connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial jG66 er, CPVC,Pex One and Two-Fanul �,46sulation/Residential Check/ Commercial Check Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape---- COMMENTS: LASueHemingway\Building.Codes.Inspection.FORM S\Rough Plumbing Insulation Report.doc November 17,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection reques ecei Queensbury Building& Code Enforcement Arrive; pm-- 742 Bay Road, Queensbury,NY 12804 - Inspector's Initi NAME: PERMIT #: LOCATION: t INSPECT ON: ' -3 6-0 TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2, R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min. Drain Size WasWng Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper, CPVC,Pex One and Two-Family -� Insulation/Residential Check/Commercial Check `. Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air S!!pply for Furnace Duct work sealed properly/No duct tape COMMENTS: LASueHemingway\Building.Codes.Inspection.FORWRough Plumbing Insulation Report.doc November 17,2003 C Framing / Firestoppirig Inspection Report Office No. (518) 761-8256 Date Inspection req t re ed- Queensbury Building& Code Enforcement Arrive: a pm`: art: f a p 742 Bay Road, Queensbury, NY 12804 Inspector's Initi s: NAME: PERMIT#: LOCATION: Z- _ -, �p INSPECT ON: Q—CjC 1 TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour restopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doe January 28,2003 Framing Firestopping Inspection Report 'rxp Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/ m part: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: �C N I PERMIT#: LOCATION: (�c-V, ( —(,r INSPECT ON: 2 0 TYPE OF STRUCTURE: - - Y N N/A COMMENTS Eraming Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2,3, 4 hour i > F'irestopping ' Penetration seal d 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/ all am/pm �j 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: 7 ( _f NAME: 9 ` �l� �J Y (1Y1-L'1� PERMIT#: ��� LOCATION: 44 Ck C C INSPECT ON: TYPE OF STRUCTURE: --. Y N ' N/A COMMENTS ;raining - Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour jF�re`s'topp.ing ACC-r� A l7 Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 518 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 r Framing /Firestopping Inspection Deport Office No. (518) 761-8256 Date Inspection request received: r O Queensbury Building&Code Enforcement Arrive: am/ art:111� r am/pm 742 Bay Road, Queensbury,NY 1.2804 Inspector's Initials: NAME: N l►J PERMIT#: D , LOCATION: V c A"R) `� INSPECT ON: TYPE OF STRUCTURE:' Y N NIA COMMENTS Framing Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses chor Bolts 6 ft, or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X . Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W ) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORMSTraming Firestopping Inspection Report.doc January 28,2003 Framing /Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/Mn Depart: am/pm 742 Bay Road, Queensbury,NY 1.2804 Inspector's Initials: 4 NAME: o PERMIT#: YYY LOCATION: is INSPECT ON: TYPE OF STRUCTURE: S Framing Y N N/A COMMENTS . Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses or Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report /� S Office No. (518) 761-8256 Date Inspection reques receiv d: f Queensbury Building&Code Enforcement Arrive: am/ m Depart: m/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: S NAME: \ �, PERMIT#: �d -- LOCATION: _<ANti (\ .2 INSPECT ON: — TYPE OF STRUCTURE: lzi� Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing L for 48 hours following the placement �f���lj l og--�— C / of the concrete. �\ Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place 0 Foundation Dampproofing Foundation/Waterproofing Ty e of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil of for wet areas under slab Back-fill Approval Bing Under Slab PVC/Cast/Copper Undation Insulation Interior/EAterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p Depart: cJ am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: C PERMIT#: _ C)LI LOCATION: JL ) INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic 'ab Reinfor lent in-Place T contractor is responsible for roviding protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval + Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report ^� PdT) Office No. (518) 761-8256 Date Inspection reques received: / Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd., Queensbuiy,NY 12804 Inspector's Initials: NAME: 1n PERMIT#: ck LOCATION: z P v INSPECT ON: IL1__=0-1-4 TYPE OF STRUCTURE: Comments % Y N N/A Fo'otings Piers Monolithic Slab Reinforcement in Place 2 3 The contractor is response le for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:1SueHemingway\Building.Codes.Inspection.FORMSToundation Inspection Report.doc January 28,2003 0q Permit Number REScheck Compliance Certificate Checked By/Date :'m m New York State Eaergy Conservation Construction Code RES checkSoftware Version 3.5 Release 1 TG f« 2004 Data filename:C:\Program Files\Check\RE 3.-04 CRONIN-49 BUCKBEE ROAD QUEEN§R�Yaoj TITLE:PLAN NO.2343-04 con COUNTY:Warren STATE:New York HDD:7635 CONSTRUCTION TYPE:Detached Tor 2 Family HEATING TYPE:Non-Electric DATE:04/02/04 DATE OF PLANS:APRIL 2,2004 PROJECT INFORMATION:. MARK&AMY CRONIN 49 BUCKBEE ROAD QUEENSBURY COMPANY INFORMATION: WILLIAMS&WILLIAMS DESIGNERS 509 GLEN STREET GLENS FALLS,NEW YORK 12801 COMPLIANCE:Passes Maximum UA=500 Your Home UA=461' 7.8%Better Than Code(UA) Gross Glazing Area or Cavity Cont: orpoor Perimeter R-Value R-Value U-Factor UA Ceiling.1:.Flat.Ceiling or.Scissor Truss 1805 38,0 0.0 54 Wall 1: Wood Frame, 16"o.c. 1977 19.0 0.0 92 Window 1:Vinyl Frame:Double Pane with Low-E 365 0.340 124 Door 1:Glass 24 0.340 8 Door 2:Glass 24 0.340 8 Door 3: Solid 32 0.130 4 Wall 2:Wood Frame, 16"o.c. 468 19.0 .0.0 28 Basement Wall 1:Solid Concrete or Masonry 1203 11.0 0.0 60 Wall height:9.0' Depth below grade:8.0' Insulation depth:9:0` Window 2:Vinyl Frame:Double Pane with Low-E 45, 0.340 15 Door 4: Solid 72 0.130 9 Door 5:Solid 72 0.130 9 Door 6:Glass 32 0.340 11 Floor 1--AR-Wood Joist/Truss--Over Outside.Air 59. 19.0. 0.0. 3. Floor 2: Slab-On-Grade:Heated 52 10.0 36 Insulation depth:6.0' Boiler 1:Other(Except Gas-Fired Steam), 87 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction-Code requirements- VAenaRegistered-Design Professional_has.stamped.and- signed this page,thloy, a attest N that t best of his/her knowledge,belief and professional judgment,such plans or specifications are in c lianc ith n 1 es'g Date REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheekSoftware Version 3.5 Release 1 DATE:04/02/04 TITLE:PLAN NO.2343-04 Bldg, l_ Dept. Use I Ceilings: [ ] I 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: C Above-Grade Walls: [ ] I 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation I' Comments:- 2. Wall 2:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: I Basement Walls: [ ] I 1. Basement Wall 1:Solid Concrete or Masonry,9.0'ht/8.0'bg/9.0'insul, R-11.0 cavity insulation Comments: I I Windows: [ ] I 1. Window 1:VinyI Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?I ]Yes[ ]No I Comments: [ ] ( 2• Window 2:Vinyl Frame-Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: f #-Panes_ Frame Type -Thermal-Break?[ ]-Yes-[ }No- Comments: I [ DoQrs:- [ ] I 1. Door 1:Glass,U-factor:0.340 Comments: [ ] I 2. Door 2:Glass,U-factor:0.340 Comments: [ ] I 3. Door 3: Solid,U-factor:0.130 Comments: [ ] 4. Door 4:Solid,U-factor:0.130 Comments: [ ] I 5. Door 5:Solid,U-factor:0.130 { Comments: [ ] I 6. Door 6:Glass,U-factor:0.340 Comments: f. Floors: [ ] I 1. Floor 1:All-Wood Joist/Truss:Over Outside Air,R-19.0 cavity insulation �. Comments: [ ] I 2. Floor 2: Slab-On-Grade:Heated,6.0'insulation depth,R-10.0 continuous insulation I Comments: { Slab insulation to extend down from the top of the slab to at least 6.0 ft.OR down to at least the bottom of the slab then horizontally for a total distance.of 6.0 ft. {. Exterior insulation must-have-a rigid,opaque,weather.-resistant.protective.covering that. { covers the exposed(above-grade)insulation and extends at least 6 in.below grade. Heating.and Cooling.Equipment: [ ] { 1. Boiler 1:Other(Except Gas-Fired Steam),87 AFUE or higher { Make and Model Number { { Air Leakage: [ ] { Joints,penetrations,and all other such openings in the building envelope that are sources of air { leakage must be sealed. [ Recessed tights must be lJ Type IC rated;or 2)installed inside an appropriate air-tight assembly { with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a { 3"clearance from insulation. { Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. { Materials Identification: [ ] { Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. [ ] { Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. { Duct Insulation: ] { Supply ducts in unconditioned'attics or outside the building must be insulated-to R It. j ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] { Supply ducts in unconditioned spaces must be insulated to R-11. [ } { Retum ducts in-unconditioned spaces(except basements}mustbe-insulatedto-l-2: { Insulation is not required on return ducts in basements. { {. Duct.Construction:. [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics I (adhesives),mastic-plus-embedded-fabric;or tapes. Duct tape is not permitted. I_ Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. { I Temperature Controls: [ ] Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. G Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction I provisions of the Building Code of New York State,the Residential Code of New York State or I the New York City Building Code,as applicable. { Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the �. water heater has.an.integral heat.trap.or.is.part.of acirculating system_ [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating_Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an'on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. C Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating.Runouts Circulating Mains and Runouts Temperature(F) Up_to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 I 7&ble 2'.• Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2"Runouts l"and Less 1.25"to 2"_ 2.5"to 4" Heating-Systems- Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water)_ Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) or believe I saw evidence of, !,,pils, trees, fences, etc., -so reppresept that I have y tances set forth on the diagram.L <—North DATE 684! Buckbee Rd. 155, sti ng 140' 208' ExIsting Shed 250' 'qePtIc ssoti- 4 Driveway 106, —> 165........ 150, Transformer Proposed pad House L/ Well i 410' 166, 5.04 Acres Lands of Mark&Amy Cronin 49 Buckbee Rd. 773, Queensbury,NY 12804