Isolatek 1
ISMLATEK CAFCO-B®AR®®
INTERNATIONkIL
CC— CoZ1—7�zs�
PRODUCT DESCRIPTION FIRE TEST PERFORMANCE
CAFCO-BOARD is a rigid mineral wool board which combines fire CAFCO-BOARD has been extensively tested for fire resistance and is
protection,thermal insulation and acoustical control all in one product. rated for up to 4 hours for floor assemblies,beams,joists,columns,and
With the ability to be installed during any phase of construction, roof assemblies.
regardless of roof traffic, temperature or substrate condition, • Classified by UL in accordance with ANSI/UL 263(ASTM E119)
CAFCO-BOARD is the ideal solution for fast paced projects. • Classified by UL in accordance with CAN/ULC-S101 (ASTM E119)
PRODUCT ADVANTAGES CAFCO-BOARD has also been tested for surface burning characteristics
• Lasting in-place performance—mechanically fastened in accordance with ASTM E84 and is rated Class A.
• 70%recycled content(pre-consumer) Plain Flame Spread.......0 Smoke Developed.......0
• Inorganic composition Foil Faced Flame Spread.......15 Smoke Developed.......5
• Available in pre-manufactured thicknesses according to UL design criteria
• Choice of unfaced,silver or white foil faced finish
• NRC of up to 1.1 for noise reduction coefficient Thermal Performance
• Thermal resistance(R-value)up to 4.2 Product Conductivity(k)* Resistance(R/inch)
CAFCO-BOARD 0.24 BTU in/hr ft"F @ 75•F 4.2
(0'.034 Wlm•K@24-C)
*When tested in accordance with ASTM C518
Noise Reduction Coefficients*
Technical Information 113 Octave Band Center Frequency HZ
Nominal Density 9 pcf(144 kg/m3) 125 250 500 1000 2000 4000 NRC
Standard Dimension 2'x 4'(610 x 1219 mm) 2 in(51 mm) 0.18 0.75 1.17 1.06 1.00 0.81 1.00
Thickness Range 1"to 4%"(25 to 114 mm) 4 in(102 mm) 0.49 1 1.11 1.11 11.14 0.97 0.64 1.10
Finish Unfaced,silver foil faced,white foil faced *Data on Unfaced CAFCO-BOARD,when tested in accordance with ASTM C423
Recycled Content 70%(pre-consumer) Sound Transmission Class (STC) Data
Method of Attachment Patented friction fit Cafclips,welded pins and clinch 1 in(25 mm) 10
shields
2 in(51 mm) 15
3 in(76 mm) 18
Hourly Rating
Columns 1 1% 2 3 4
W6x16 to W8x28(W150x24 to W200x42) • • • X314
W10x49(W250x73) • • • • X314
W12x106 to W14228(W310x158 to W360042) • • • • • X314
Protected Floor/Ceiling Assemblies Minimum Concrete Thickness
Electrified floor decks 2"—3"deck 2-'/='concrete • • • • D301
Floor Assembly 2"—3"deck 2-W'concrete • • • • D301
Unprotected Floor/Ceiling Assembly
Floor Beam 31/4 LW Concrete • • • D915
Beam Only Floors Minimum Concrete Thickness
Floor Beam Only Rating 2-%"concrete • • • N308
Floor Beam Only Rating 2-%"concrete • • • • N308
Roof/Ceiling Assemblies(Includes Beams And Joists)
Polyisocyanurate or Mineral and Fiber Boards • • • P301
Lightweight Insulating Concrete • • . P301
i I
.Is h: Jis lvc caU IK3-:i'i.r..! Brand
CAFCO-BOARD Guide Specification
SECTION 078200-BOARD FIREPROOFING 1.3 Related Sections 1.6.5 Do not enclose rigid board fire protection until 3.2 Installation/Application
The following is an oudinelshort language application. application is completed and inspected by
complete specificotions for the Rigid Board Fire 1.3.1 SECTION 072100-THERMAL INSULATION authorities having jurisdiction. 3.2.1 Comply with manufacturer's written instructions for
Protection is available an various media upon request. 1.3.2 SECTION 078100-APPLIED FIREPROOFING particular conditions of installation in each case.
1.3.3 SECTION 078123-INTUMESCENT PART 2-PRODUCTS 3.2.2 Install rigid board fire protection to comply with
PART 1-GENERAL FIREPROOFING requirements for thicknesses,number of courses
1.3.4 SECTION 078413-PENETRATION 2.1 Manufacturers (layers),construction of joints and corners,and
1.1 Work Included FIRESTOPPPING anchorage methods applicable to fire resistance
2.1.1 The rigid board fire protection shall be rated assemblies indicated.
1.1.1 Specify to meet project requirements.Provide 1.3.5 SECTION 092900-GYPSUM BOARD manufactured under the CAFCOe brand name,by
all labor, materials, equipment and services aulhorized producers. 3.3 Protection
necessary for,and incidental to,the complete and 1.3.6 SECTION 099123-INTERIOR PAINTING
proper installation of all sprayed fire protection 2.1.2 CAFCO-BOARD Rigid Board Fire Protection(UL 3.3.1 Coordinate installation of rigid board fire protection
and related work as shown on the drawings 1.4 Submittals Designation:Type CB)and related accessories with other construction trades to minimize cutting
P 1.4.1 Product Dala lobe submitted with manufacturers shall be provided by ISOLATEK International into, or removal of, already or where specified herein,and in accordance y installed board
PP q specification, including certification as may and shall be installed in accordance with current
with all applicable requirements of the Contract material. As construction by other trades is
Documents. p 9 y printed instructions. successively completed,replace or repair rigid
be required to show material compliance with
1.1.2 The material and installation shall conform to Contract Documents 2.2 Materials board fire protection installations,incdance have been
removed or cut away,in accordance with 3.32.
the applicable building code requirements of all 1.4.2 Product Certificates or test reports from, 2,2,1 Materials shall be CAFCO-BOARD, (UL/ULC Maintain complete thickness on steel members
authorities having jurisdiction. and based on tests performed by, qualified designation,Type CB)produced from materials by and assemblies protected by fire protection.
1.1.3 Drawings general provisions of the Contract, independent testing and inspection agency y refractory 3.3.2 All patching and repairlorigidboard fire protection
9 9 P combining refracto mineral wool manufactured
includingGeneral and Supplementary Conditions acceptable to authorities having jurisdiction. P g due to damage by other trades shall be performed
Pp y from slap with thermosetting resin binders,to
and Division 01 Specifications Sections,apply to Include test results and their interpretations under this section and paid for by the trade
p ppy complywith ASTM C-612 for Class 4,nominal
this Section. which evidence compliance of current mineral density of gpcf(144g/m'),applied to conform responsible for the damage.
wool board fire protection with from Independent to the drawings,specifications and following test
1.2 quality Assurance laboratory test results for all specified criteria: 3.3.3 Provide final protection and maintain conditions
performance criteria, in a manner acceptable to Installer.Manufacturer,
1.2.1 Work shall be performed by a firm with expertise 2.2.2 Thermal Conductivity(R valuefinch):4.2 at 75'F and authorities having jurisdiction that ensures
in the installation of fire protection or similar 1.4.3 Research/Evaluation Reports of the model code (24•C)per ASTM rigid board fire protection is without damage or
materials. This firm shall be recognized or organization acceptable to authorities having
otherwise approved by the Rigid Board fire jurisdiction which evidence mineral wool board's 2,23 Surface Burning Characteristics:Maximum Flame deterioration al time of Substantial Completion.
resistive material manufacturer. fire protection compliance with the building code Spread and Smoke Developed ratings of 0 and 15, 3,4 Field Quality Control
applicable to the project. respectively.
1.2.2 Fire Test Response Characteristics: Provide 3.4.1 Inspection Agency: Engage a qualified
rigid board fire protection with identical fire 1.5 CoordlnadonlSequencing 2.2.4 Fastening Accessories: For each fire resistive independent inspecting agency to inspect rigid
performance characteristics to those which have assembly in which rigid board fire protection board fire protection and prepare inspection
been determined per test methods indicated 1.5.1 Sequence and coordinate installation of board fire serves as rigid fire protection,provide a board
below and have been tested by UL or other testing protection with related construction operations fastening system complying to the related UL reports.
organizations acceptable to authorities having specified in other sections to comply with the design or other acceptable testing and inspection 3.4.2 Testing Services: Inspecting of completed
jurisdiction. following requirements: organization's report. installations of rigid board fire protection shall lake
1.2.2.1 Surface Burning characteristics:ASTM E84 1.5.2 Avoid unnecessary exposure of rigid board fire place in successive stages as installation of rigid
protection to abrasion and other damage likely to PART 3-EXECUTION board fire protection proceeds. Do not proceed
1.2.2.2 Fire Resistance Ratings and Fire Resistance occur during construction operations subsequent with installation of rigid board fire protection for
Assemblies: Provide rigid board fire to its application. 3A Preparation the next area until inspecting agency determines
protection with ratings indicated by the completed work shows compliance with
appropriate UL or equivalent design based on 1.5.3 Do not install rigid board fire protection on 3,1.1 Examine substrates and conditions under which requirements.
ASTM E-119(UL263,CAN/ULC-S101)testing structural members until piping and other rigid board fire protection construction is to be
requirements. construction behind the fire protection has been installed. Do not proceed with installation of the Product Availability
1.2.2.3 Combustion Characteristics:ASTM E136
completed. rigid board fire protection until unsatisfactory ISOLATEK International Rigid Board Fire Protection
a
1.5.4 Expedite installation of rigid board fire protection conditions have been corrected. Is available to trained,recognized PPlicators around
1.2.2.4 Fire resistance rated assemblies/designs are to minimize exposure of structural members the world from strategically located production and
listed in the UL Fire Resistance Directory or without fire protection. distribution points In the U.S,Canada,Mexico,Europe
and the Pacific Basin.
equivalent publication.
6EgUII AE1l,UC4,1
r ISOLATEK INTERNATIONAL is registered with the
AIA Continuing Education System(AIA/CES)
407 qp3
We support our customers with unsurpassed technical expertise and customer service,complemented by an extensive global network of experienced sales
representatives and recognized applicators.For detailed product information or for the name of the sales representative in your area please contact us.
The performance data herein reflect our expectations based on tests conducted in accordance with recognized standard methods under controlled conditions. The applicator,
general contractor,property owner and/or user MUST read,understand and follow the directions,specifications and/or recommendations set forth in Isolatek International's
publications concerning use and application of these products,and should not rely merely on the information contained in this product data sheet. Isolatek Intemational is not
responsible for property damage,bodily injuries,consequential damages,or losses of any kind that arise from or are related to the applicator's,general contractor's,or property
owners'failure to follow the recommendations set forth in Isolatek International's publications.The sale of these products shall be subject to the Terms and Conditions set forth
in the Company's invoices.
Isolatek International provides passive fireproofing materials under the CAFCO®
trademark throughout the Americas and other markets and under the m
ISOLATEKO trademark throughout the world-
ZZ
0
800.631.9600 or 973.347.1200 IS�LATEK® o
Brand www.isolatek.com I technical0isolatek.com Brand