JB201133.0091.Grout Compressive Strength Test.2021-01-28.Rpt.0091Rev1GROUT COMPRESSIVE STRENGTH TEST REPORT
Report Number:
Service Date:
Report Date:
Task:
Client
JB201133.0091
01/28/21
02/25/21 Revision 1 - 28-day results
30 Corporate Cir Ste 201
Albany, NY 12203-5169
518-266-0310
Rosetti Acquisitions LLC
Attn: Christopher Falvey
427 New Karner Rd
Albany, NY 12205
Fowler Square SI and CMT
Bay Road and Blind Rock Road
Queensbury, NY 12804
Project
Project Number: JB201133
Sample Information
Sample Date:
Sampled By:
Weather Conditions:
Sample Size:
Sample Location:
Sample Time:01/28/21 1245
J. Canonico
Clear
Accumulative Yards:Batch Size:
prefabricated
Tub
Placement Location:Mixed Use Bldg. Stair/Elevator 2 walls
infill, 8-12'.
Form Material:
Samples Plumb:
Cardboard Form No. Units:1
Yes
Temperature Range:
Specified Strength:psi @ days
Mix ID:
Supplier:
Batch Time:
Material Information
Plant:
Field Test Data
Test
Grout Temp. (F):
Ambient Temp. (F):
Result Specification
28
FG3000
Package Pavement
1230
Truck No.:Ticket No.:
8
60
24
Slump (in):
3,000
Laboratory Test Data
No.
Date Age Area
(lbs)
Load Strength
Compressive
ID Received
Date
Tested (days)(sq in)(psi)
Maximum
SpecimenSet Tested
By
1 A 02/01/21 02/04/21 7 11.87 44,690 3,770 ADB
1 B 02/01/21 02/25/21 28 12.36 52,140 4,220 ADB
1 C 02/01/21 02/25/21 28 12.32 51,220 4,160 ADB
Average (28 days) 4,190
1 D 02/01/21 Hold 12.04
Initial Cure:Final Cure:Inside Moist Room
Comments:Average compressive strength of 28 day Prism complies with the specified strength. **NP = Not Performed
Package Pavement FG3000 Fine Grout, 3000 psi @28 days. Work was enclosed and heated, about 61 F.
Samples Made By: Dente Group - A Terracon Co.
Obtain sample of grout used as wall fill, perform required field tests and cast compressive strength samples.Services:
Reported To:
Contractor:
Report Distribution:
(1) Rosetti Acquisitions LLC, Christopher Falvey (1) 260 Structural Engineering, Dan Thomas
(1) BBL Construction Services, Bobby Chatterton (1) BBL Construction Services, Eric Weatherwax
(1) BBL Construction Services, Ryan Etue (1) Galusha & Sons LLC, Drew Stevens
(1) Galusha & Sons LLC, James Campagnone
Staff Geologist
Jared Hall
BBL
BBL Superintendent
Reviewed By:
Test Methods:ASTM C 31, ASTM C39, ASTM C109, ASTM C138, ASTM C143, ASTM C1019, ASTM C1064
Dente Group - A Terracon Co. Rep.: J. Canonico
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
CR0009, 11-16-12, Rev.6 Page 1 of 1