JB201133.0091.Grout Compressive Strength Test.2021-01-28.Rpt.0091Rev1GROUT COMPRESSIVE STRENGTH TEST REPORT Report Number: Service Date: Report Date: Task: Client JB201133.0091 01/28/21 02/25/21 Revision 1 - 28-day results 30 Corporate Cir Ste 201 Albany, NY 12203-5169 518-266-0310 Rosetti Acquisitions LLC Attn: Christopher Falvey 427 New Karner Rd Albany, NY 12205 Fowler Square SI and CMT Bay Road and Blind Rock Road Queensbury, NY 12804 Project Project Number: JB201133 Sample Information Sample Date: Sampled By: Weather Conditions: Sample Size: Sample Location: Sample Time:01/28/21 1245 J. Canonico Clear Accumulative Yards:Batch Size: prefabricated Tub Placement Location:Mixed Use Bldg. Stair/Elevator 2 walls infill, 8-12'. Form Material: Samples Plumb: Cardboard Form No. Units:1 Yes Temperature Range: Specified Strength:psi @ days Mix ID: Supplier: Batch Time: Material Information Plant: Field Test Data Test Grout Temp. (F): Ambient Temp. (F): Result Specification 28 FG3000 Package Pavement 1230 Truck No.:Ticket No.: 8 60 24 Slump (in): 3,000 Laboratory Test Data No. Date Age Area (lbs) Load Strength Compressive ID Received Date Tested (days)(sq in)(psi) Maximum SpecimenSet Tested By 1 A 02/01/21 02/04/21 7 11.87 44,690 3,770 ADB 1 B 02/01/21 02/25/21 28 12.36 52,140 4,220 ADB 1 C 02/01/21 02/25/21 28 12.32 51,220 4,160 ADB Average (28 days) 4,190 1 D 02/01/21 Hold 12.04 Initial Cure:Final Cure:Inside Moist Room Comments:Average compressive strength of 28 day Prism complies with the specified strength. **NP = Not Performed Package Pavement FG3000 Fine Grout, 3000 psi @28 days. Work was enclosed and heated, about 61 F. Samples Made By: Dente Group - A Terracon Co. Obtain sample of grout used as wall fill, perform required field tests and cast compressive strength samples.Services: Reported To: Contractor: Report Distribution: (1) Rosetti Acquisitions LLC, Christopher Falvey (1) 260 Structural Engineering, Dan Thomas (1) BBL Construction Services, Bobby Chatterton (1) BBL Construction Services, Eric Weatherwax (1) BBL Construction Services, Ryan Etue (1) Galusha & Sons LLC, Drew Stevens (1) Galusha & Sons LLC, James Campagnone Staff Geologist Jared Hall BBL BBL Superintendent Reviewed By: Test Methods:ASTM C 31, ASTM C39, ASTM C109, ASTM C138, ASTM C143, ASTM C1019, ASTM C1064 Dente Group - A Terracon Co. Rep.: J. Canonico The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0009, 11-16-12, Rev.6 Page 1 of 1