Loading...
JB201133.0125.Concrete Compressive Strength Test.2021-03-02.Rpt.0125Report Number: Service Date: Report Date: Task: Client Queensbury, NY 12804 Bay Road and Blind Rock Road Fowler Square SI and CMTRosetti Acquisitions LLC Attn: Christopher Falvey 427 New Karner Rd Albany, NY 12205 518-266-0310 Albany, NY 12203-5169 30 Corporate Cir Ste 201 JB201133.0125 03/02/21 03/10/21 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Project Project Number: JB201133 Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 35000 Pallette Stone Material Information 1300 4905 Plant: Ticket No.:844948 Field Test Data Test Air Content (%): Result Specification 3 1/2 2 - 4 5.4 4.5 - 7.5 60 40 - 95 25 3,500 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:03/02/21 1400 Bryan Smith Sunny, Windy, and Cold 9 9 Point of PlacementSample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Piers @ N-25, N-26, M-27, P-28, and M-28 – Foundation Wall between E.5-25 and F-29 Placement Location: Laboratory Test Data Set Avg Diam.Area Weight DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) Tested By(lbs) 1 A 4.00 12.57 03/03/21 8.55 03/09/21 7 43,980 2 3,500 ADB 1 B 4.00 12.57 03/03/21 8.55 03/30/21 28 1 C 4.00 12.57 03/03/21 8.60 03/30/21 28 1 D 4.00 12.57 03/03/21 8.55 03/30/21 28 1 E 03/03/21 8.55 Hold 1 F 03/03/21 8.55 Hold Initial Cure:Final Cure:Onsite Cooler Moist Room Comments:Not tested for plastic unit weight. Samples Made By: Dente Group - A Terracon Co. Sample fresh concrete at the placement locations, perform required field tests and cast compressive strength samples.Services: Reported To: Contractor: Report Distribution: (1) Rosetti Acquisitions LLC, Christopher Falvey (1) 260 Structural Engineering, Dan Thomas (1) BBL Construction Services, Bobby Chatterton (1) BBL Construction Services, Eric Weatherwax (1) BBL Construction Services, Ryan Etue (1) D.A. Collins Construction Co Inc, Robin Stothers (1) Galusha & Sons LLC, Drew Stevens (1) Galusha & Sons LLC, James Campagnone Jared Hall Staff Geologist Bobby w. BBL Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Dente Group - A Terracon Co. Rep.: Bryan Smith The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6