Signed Inspection Report (Mon Mar 15, 2021 at 257 PM)INSPECTION WORKSHEET (FDTN-008867-2021)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0744-2020 Case Module:Permit
Inspection Date:Mon Mar 15, 2021 Inspection Status:Partial Pass
Inspector:Smith, Mark Inspection Type:Building Foundation
Job Address:Parcel Number:19 ST JAMES PL
Queensbury, NY, 12804
309.10-1-97
Contact Type Company Name Name
Granted Permission HAYES & HAYES LLC
Primary Owner HAYES & HAYES LLC
Contractor HAYES & HAYES LLC
Architect Rucinski-Hall Architecture
Applicant HAYES & HAYES LLC
Checklist Item Status
Permit Card Visible From Road Failed
Building Inspector Notes Failed
3/5/21 footings approved
3/9/21 partial approval for foundation walls, half the foundation is formed and will be poured that the forms will be
move to do the other half, provide an updated drawing from the architect showing the rebar at the center wall
pinned to exterior walls.
3/15/21 foundation walls approved. rebar at center wall verified, provide detail from architect showing rebar
pinned at each end of center wall.
Footings Passed
Mar 15, 2021 Page (1)
INSPECTION WORKSHEET (FDTN-008867-2021)
Checklist Item Status
3/5/21 footings approved
Piers Failed
Monolithic Slab Failed
Reinforcement in Place Passed
2 rows of #4 rebar continuous, vertical dowels to be wet set
Foundation / Wallpour Passed
3/12/21 verified remainder of wall for building 11 pinned into previous pour. As noted provide specs for rebar
schedule
Reinforcement in Place Passed
2 rows of #4 rebar one foot from top and bottom of wall
Masonry Wall Failed
Reinforcement in Place Failed
Footing Dowels or Keyway in place Passed
#4 rebar 48" on center 12/16" above footing
Foundation Dampproofing Failed
Foundation Waterproofing Failed
Footing Drain Daylight or Sump Failed
Mar 15, 2021 Page (2)
INSPECTION WORKSHEET (FDTN-008867-2021)
Checklist Item Status
Footing Drain Stone - 12 inch width Failed
Footing Drain Stone - 6 inches above footing Failed
Footing Drain stone - 6 mil poly Failed
Backfill Approval Failed
Plumbing Under Slab Failed
PVC / Cast / Copper Failed
Foundation Insulation Interior / Exterior Failed
Rough Grade 6 inch drop within 10 ft.Failed
Poly Under Slab Failed
Mar 15, 2021 Page (3)
Smith, Mark