JB201133.0110.Mortar Compressive Strength Test.2021-02-17.Rpt.0110Rev1MORTAR COMPRESSIVE STRENGTH TEST REPORT Report Number: Service Date: Report Date: Task: Client JB201133.0110 02/17/21 03/17/21 Revision 1 - 28-day results 30 Corporate Cir Ste 201 Albany, NY 12203-5169 518-266-0310 Rosetti Acquisitions LLC Attn: Christopher Falvey 427 New Karner Rd Albany, NY 12205 Queensbury, NY 12804 Bay Road and Blind Rock Road Fowler Square SI and CMT Project Project Number: JB201133 Sample Information Sample Date: Sampled By: Weather Conditions: Sample Size: Sample Location: Sample Time:02/17/21 1030 J. Canonico Clear 2"x2"x2" Pan Placement Location:Mixed Use Bldg. Stair 3 CMU walls mortar joints, courses 3-5 at N, E & W. walls, courses 1-3 at S. wall. Test Mold Material: Curing Procedure: Other - See Comments ASTM C 109 psi @ days Mix ID: Supplier: Batch Time: Material Information Plant: Field Test Data Test Mortar Temp. (F): Ambient Temp. (F): Result Specification Mortar Type:S 1,800Specified Strength:28 Type S Mortar Package Pavement 0930 44 48 Laboratory Test Data No. Date Age Area (lbs) Load Strength Compressive ID Received Date Tested (days)(sq in)(psi) Maximum Set Specimen Tested By 1 A 02/19/21 02/24/21 7 4.08 8,550 2,100 ADB 1 B 02/19/21 02/24/21 7 4.08 8,820 2,160 ADB Average (7 days) 2,130 1 C 02/19/21 03/17/21 28 4.06 12,290 3,030 ADB 1 D 02/19/21 03/17/21 28 4.08 11,960 2,930 ADB Average (28 days) 2,980 1 E 02/19/21 Hold 1 F 02/19/21 Hold Initial Cure:Inside Final Cure:Moist Room Comments: Note: The indicated Specified Strength above is for laboratory batched and cast specimens under controlled conditions. Strength tests of field cast specimens are to be used to monitor trends and batch to batch consistency of mortar per ASTM C 270 and are not intended as criteria to determine the acceptance or rejection of the mortar as installed. Average compressive strength of 28 day Cube complies with the specified strength. Package Pavement Type S preblended mortar, 1800 psi @28 days. Polypropelene Molds. Outside temperature about 17 F. Work was enclosed and heated. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0008, 11-16-12, Rev.6 Page 1 of 2 MORTAR COMPRESSIVE STRENGTH TEST REPORT Report Number: Service Date: Report Date: Task: Client JB201133.0110 02/17/21 03/17/21 Revision 1 - 28-day results 30 Corporate Cir Ste 201 Albany, NY 12203-5169 518-266-0310 Rosetti Acquisitions LLC Attn: Christopher Falvey 427 New Karner Rd Albany, NY 12205 Queensbury, NY 12804 Bay Road and Blind Rock Road Fowler Square SI and CMT Project Project Number: JB201133 Samples Made By: Dente Group - A Terracon Co. Obtain a sample of masonry mortar used during construction and cast 2-inch cube specimens for consistency verification.Services: Reported To: Contractor: Report Distribution: (1) Rosetti Acquisitions LLC, Christopher Falvey (1) 260 Structural Engineering, Dan Thomas (1) BBL Construction Services, Bobby Chatterton (1) BBL Construction Services, Eric Weatherwax (1) BBL Construction Services, Ryan Etue (1) D.A. Collins Construction Co Inc, Robin Stothers (1) Galusha & Sons LLC, Drew Stevens (1) Galusha & Sons LLC, James Campagnone Staff Geologist Jared Hall BBL BBL Superintendent Reviewed By: ASTM C109, ASTM C780Test Methods: Dente Group - A Terracon Co. Rep.: J. Canonico The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0008, 11-16-12, Rev.6 Page 2 of 2