Signed Inspection Report (Wed Mar 24, 2021 at 110 PM)INSPECTION WORKSHEET (RESFINAL-009103-2021)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0348-2018 Case Module:Permit
Inspection Date:Wed Mar 24, 2021 Inspection Status:Passed
Inspector:Dyer, Charles Inspection Type:Residential Final Inspection
Job Address:Parcel Number:33 SMOKE RIDGE RD
Queensbury, NY, 12804
308.8-1-21.42
Contact Type Company Name Name
Granted Permission FOOTHILLS BUILDERS, LLC
Applicant FOOTHILLS BUILDERS, LLC
Primary Owner FOOTHILLS BUILDERS, LLC
Contractor FOOTHILLS BUILDERS, LLC
Architect Rucinski-Hall Architecture
Checklist Item Status
General Comments Failed
4 inch Building Number Address visible from road Passed
Fresh Air Intake Passed
Fresh air supply 3' from grade Passed
3" Plumbing Vent through roof minimum 18 inch Passed
Mar 24, 2021 Page (1)
INSPECTION WORKSHEET (RESFINAL-009103-2021)
Checklist Item Status
Outside Spigots have Air Gap Passed
Roof Complete / Exterior Finish Complete Passed
Platform at all exterior doors Passed
Handrail 4 or more risers Passed
Guards at stairs,decks,patios 30" + above grade Passed
Guard at stairwell at 34" or more Passed
Window guards req:<2' above floor/6' above grade - quick release installed Passed
Guard at deck, porches 36" or more Passed
Handrail Termination at Newell Post or Wall Passed
Interior/Exterior Railings 34 to 38 Passed
Wood deck: 2'+ from grade dia bracing required - H/C ramp compliant Passed
4+ Deck Joist Ledger Connections-24" From Ends Passed
Mar 24, 2021 Page (2)
INSPECTION WORKSHEET (RESFINAL-009103-2021)
Checklist Item Status
Deck Ledger-Bolted per Code Passed
Grade away from foundation: 6" down, 10' out Passed
6" clearance to sill plate Passed
Gas Shut-off Exposed & Regulator (18) Above Grade Passed
Interior privacy/trim/doors/main entrance 36 Passed
Bathroom / Kitchen Watertight Passed
Low flow toilet 1.3 gal/flushing cycle - showerhead/faucet Passed
Safety glazing: w/in 5' of tub/shower - stairwell win/adj to drs Passed
Smoke Detectors: Carbon Monoxide Passed
Smoke Detectors 3' from Kitchens & Baths R314 Passed
Every level, Every bedroom Passed
Mar 24, 2021 Page (3)
INSPECTION WORKSHEET (RESFINAL-009103-2021)
Checklist Item Status
Outside every bedroom area Passed
Inter Connected Passed
Battery backup: _____Passed
Attic Access 22 x 30 minimum Passed
Attic Access Insulation = Attic R- Value Passed
Attic Access Gasketed Passed
Bathroom Fans, if no window Passed
Plumbing fixtures Passed
Backflow Preventors where required Passed
Foundation insulation to floor Passed
Energy Sticker on Elec. Panel:R-Val. & Heating Sys Passed
All Hot Water Systems: 3/4" or larger piping R-3 Passed
Mar 24, 2021 Page (4)
INSPECTION WORKSHEET (RESFINAL-009103-2021)
Checklist Item Status
Duct work sealed properly Passed
Intake Openings Passed
Range Hood 400+ cfm-Fresh Air REQUIRED NA
Blower Door Test Certification Passed
HRV or ERV Installed per Bedroom Requirements Passed
Emergency egress below grade Passed
Furnace shut-off w/in 30 ft. or w/in line of site Passed
Furnace/Hot Water Heater operating Passed
Low water shut-off boiler NA
Relief Valve ,Heat Trap/Water Temp 110 deg or less Passed
Encl. Stairs Sheetrock Underside minimum ½ Gypsum Passed
Mar 24, 2021 Page (5)
INSPECTION WORKSHEET (RESFINAL-009103-2021)
Checklist Item Status
1/2" Gypsum or House Wall and Gable Passed
20 Minute Fire Door/Self-Closing Hardware Passed
Seals on Garage Doors, esp. Wood Passed
Basement stairs closed rise greater than 4 inches Passed
Basement Egress: 5s.f. window w/sill or Bilco door Passed
Jack posts in basement lagged at top and bottom Passed
Garage Floor Pitched Passed
Fin Elect; Energy Saving Light Bulbs 50 Percent Passed
CSST/other piping in conduit if buried,if required NA
Final Survey Plot Plan Passed
Arc Fault Breaker Habitable Spaces Passed
Flex Gas Pipe Bonding Passed
Mar 24, 2021 Page (6)
INSPECTION WORKSHEET (RESFINAL-009103-2021)
Checklist Item Status
As Built Septic System Passed
Sewer Dept. Inspection Sticker NA
Site Plan / Variance required Passed
No
Flood Plain Certification, if required Passed
No
Fuel Tanks above flood plain elevation Passed
No
Buried Fuel Tanks anchored in flood zone Passed
No
Truss ID Signage Installed at Electrical Meter Passed
OK to Issue Temporary C/O Passed
OK to issue temp C/O under conditions of storm water certification to be completed.
OK to Issue C/O Passed
Storm water verification completed and approved by engineer and zoning compliance officer.
Mar 24, 2021 Page (7)
Dyer, Charles