Signed Inspection Report (Thu Mar 25, 2021 at 157 PM)INSPECTION WORKSHEET (SEP-009099-2021)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0394-2020 Case Module:Permit
Inspection Date:Thu Mar 25, 2021 Inspection Status:Partial Pass
Inspector:Dyer, Charles Inspection Type:Septic
Job Address:Parcel Number:71 ROUND POND RD
Queensbury, NY, 12804
296.5-1-8
Contact Type Company Name Name
Granted Permission FOOTHILLS BUILDERS, LLC
Applicant FOOTHILLS BUILDERS, LLC
Primary Owner Terre Majestic Holdings, LLC
Contractor FOOTHILLS BUILDERS, LLC
Checklist Item Status
Permit Card Visible From Road Passed
In house
Building Inspector Notes Failed
Roof gutters don't discharge over leach field Passed
No
Soil Type: Sand Passed
Soil Type: Loam Passed
Type of Water: Municipal / Well Water Passed
Mar 25, 2021 Page (1)
INSPECTION WORKSHEET (SEP-009099-2021)
Checklist Item Status
Municipal
Waterline separation distance Passed
Well separation distance NA
Well Casing Lengt: 50ft +/-NA
Absorbtion Fields: Total Length Passed
160 ft
Septic system field above flood plain Passed
Yes
Sump pump not connected to septic system Passed
No
Septic tanks & pump station anchored in flood zone NA
Water softener not hooked to septic system NA
Length of Each Trench Passed
40 ft
Depth of Trenches Passed
12+"
System Use Status Passed
Verified flow into tank for verification of connection
Mar 25, 2021 Page (2)
INSPECTION WORKSHEET (SEP-009099-2021)
Checklist Item Status
Size of Stone Passed
#2
Building to Tank Passed
4" SCHD 40
Tank to Distribution Box Passed
4" SCHD 40
Distribution box to Field / Pit Passed
4" SDR 35 to 4" sewer and drain perforated
Opening Sealed:Passed
End Cap Passed
InletOutlet Pipes & Baffles Passed
Manholes 12 or less below grade Passed
No
[Provide extension collar if Yes]Passed
No
Locations / Separations Passed
Foundation to Tank Passed
Tank is 11 feet from side door @ garage
Foundation to Absorption Passed
Mar 25, 2021 Page (3)
INSPECTION WORKSHEET (SEP-009099-2021)
Checklist Item Status
Field is off left corner of garage looking at garage 21 ft
Engineer Report and As-Built Failed
Provide engineer asbuilt
Location of system on property Passed
Left side of driveway looking at home
Mar 25, 2021 Page (4)
Dyer, Charles