2004-447 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building & Codes (518) 761-8256
CERTIFI_CATE__OF OCCUPANCY
::_ P.ermit Number:.: P20040447. _ :. _ Tate Issued: Friday, December 17, 2004
__This is.to certify thatwork requested to be done as shown by_Permit Number P20040447
has been completed.
Tax Map Number: 523400-316-005-0001-015-000-0000
Location: 30 EAGAN Rd
Owner: GREGORY &KELLY CORBETT
Applicant: GREGORY &KELLY CORBETT
This structure may be occupied as a:
By Order of Town Board
Garage - 1 Car Attached : TOWN OF QUEENSBURY
Residential.Addition
Director of Building&Code.Enforcement
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20040447 Application Number: A20040447
Tax Map No: 523400-316-005-0001-015-000-0000
Permission is hereby granted to: GREGORY&KF,UN CORBETT
For property located at: 30 EAGAN Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Tie of Construction Value
Owner Address: GREGORY&KELLY CORBETT
3 0 EAGAN Rd Garage- 1 Car Attached
QUEENSBURY, NY 12804 Residential Addition $71,650.00
Total Value $71,650.00
Contractor or Builder's Name /Address Electrical Inspection Agency
JELLEY&BiJRKE CONSTRUCTION
115 MOT JNTAINVTEW Ln
OIJEENSBIJRY_ NY 12804-0000
Plans&Specifications
2004-447
786 SQ FT RESIDENTIAL ADDITION (REMOVING EXISTING GARAGE)W/480 SQ FT 1-CAR
ATTACHED GARAGE
$142.32 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday, July 07, 2005
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town,,ofQu/ nsbujWz W day, July 07, 2004
SIGNED BY ( r. 'tjlb•7X rl r for the Town of Queensbury.
Director of Building&Code En orcement
-w
Check Residential Plan Review: One &Two Family Dwellings
Y/N/N7A �
(2)Full sets of plans
Over 1,500 sq. ft.—Stamped
Design Loads On Plans: 90 Wind Floor Loads 40 psf
70 Ground Snow Load Sleeping Areas and Attics 30 psf
Calculations:
Window Schedule With Glass Size ,
Door Schedule/Main Entrance 36"Door
Emergency Escape Or Bedrooms and Habitable Space
1/ Above/Below grade, 5.7 sq.ft.
1/ Grade,5.0 sq.ft.
24"(h)x 20"(w)min.
44"Max.Height above floor
Residential Check Paperwork Compliance and Inspectors Checklist: OK
Dampproofmg/Waterproofing Materials On Plans
F/ Foundation Drainage On Plans,if required
6"Drop in 10'Exterior Grade
Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where
Required
Iee and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls
r✓ Platforms At Exterior Doors
i/ tairway Headroom 6' 8'All Stairs 36"Width
Stair Run and Rise
Winder Run and Rise
Spiral Not Allowed From 2n Story
J. Smoke Detectors Battery Backup and Proper Location
Bathroom Fixtures Proper Clearance
" Ball Width,36"min.
Handrails More Than One Riser On Open Sides
Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht.
Safety Glazing Notes For Required Areas
vl/Garage Fire Separation
Garage Floor Sloped
Attic Access
oof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access
Carbon Monoxide Detector Lowest Sleeping Level
Soil Test Results,if required
Septic To Well Or Water Line Separation
All Paperwork Signed
~Job Site Address: 50 Date:
Application No. File No. �(
Owner: �� 1<�`1 �c �H
WINDOW SCHEDULE
��•'`•"z ''5+1�. •'�'zr:;c,a'"a
.Y,w.AS'q...:'tAf�:^ wow
Window Window Mfg. Window Unit or � g11. gh' TQrsF� SQ F , Clear Clear Special Hardware or
Number or Name Model Stock Opettttp` ; ! eztng ; Mass tstbitress/ 1'e;i Ceztig Q,pgrztng,k� lghi Instructions
Y, o ie
Letter on Or Type Number «� a � I$ � a ,k�t $ 1iXn r� ,
a...s A $Cal Size t z i°
NO;,slsn ^ c 9 .F: s a
f .
0„ !!
6 0" y 2-
5- 3as-n zA 7-Z 4o,t V
Panes l 3�; » A/
L3 g/-Vy F/
-THIS LINE HAS EXAMPLES OF SAMPLE ENTRIES
p Bred
s'.a� x� ��,:!+;�: �_ ^3'z��1/3•^�"�.';,()�f 'r .IrJ`�"�� �` �$ �a� t�;�.;�' �I;t�, i� ;'
��tYs;;`c .ri �•�! +.:�t�rq'A �,' "yk Ac z �.1•»ss.�: ;T:.. :?LfHz;, .C .t,�i � �� { e;1 `.a'• �.
_�., y�.� :�,�. �=. ���r 3 �5;z:.' .� .�,.�, � �. :�.,��s111:6,.•.::. lazingall
a s.,.:r.. �'�a:.'kf...,f"'gi8'o .�t .`'S _t: •,§•�. t+ `phi < u� :;R K� �`.�.�� _-rtr.•4��".{'•..F+*:rr' ..,gw,. •,.r, �'
..�• >.i:. ,t'„ �* dF ";,ram r.�g,'.r }� Ka',:��'oi %n�a,. �z. ,.6A.�'. `o-. ::�-i`: ..F,,..,�, zr l?r,;s,'
�.:.r`� x,'.z s;; i. '.r�+`S,p,�!; i �'•�+Ec t�..��,�.� - �'t?x:�r. �I:n n..� -,.,�2" x.,.._^g?. a, "�'.°.� w,�
;,J`� u'u';6 ^;..,+�'!';`�r."�r��� `T.�'c'r�l::':2.��'^ s,: -^,$u, ;,z w.:r. '� ti`'.� .�` µc.;2.�•.: �r ;�-,� s�, '�
�Z ry Q,W
rri c r' M
L:15ueHemingway\Building,Permit.FORMS\Window Schedule.doc
Job Site Address: 30 9. gG,y, JW Date:
t
Owner: Application No. File No.
Building Permit — Calculation Sheet
Natural Light, Ventilation & Emergency Egress Requirements
Habitable Area of Req.Light Actual Req.Vent Actual Y' Sq.Ft. Remarks
Room Room 8%of Room Light '° 4%of Room Vent Opening for
in Area Square Area Square . Egress
Square Footage Footage atc
Feet ZY
IDD soy �10,3 /-9 1
I 'd
�. 2-
ti
r
Ism
* y
LiT'st
Ax
Nil
, I-th,�
z�
Oc m� CZ) ®
M
-c
L:\SueHemingway\Building.Permit.FORMS\Nat.Light.Ventil.Calculation.Sheet.doc
Building Permit Application
Town of Queensbury-Dept of Community Development,742 Bay Road,Queensbury,NY
(518)761-8256
A permit must be obtained before beginning construction. Permit File No.
No inspection will be made until applicant has received a Fee paid $ Ig 3?�
valid building permit. All applicants' spaces on this Roc.Fee Paid $
application must be completed and must appear on the Reviewed By—
application form.
Applicant: e �e/� �r Owner:
Address: ZO a : "I Address: rah /
Phone#(�5 i�) 75�3 - 6Y Phone#(S7�)7�- �' BUILD QUE"I .
NG SBO
AND,CODE Y
Property Location: Lot Number: / House Number 3 O /
SubdivisionNmne: Tax Map Numb
0 New Building: ros'dcnce /commercial 'Estimated Market Value of Construction: $ 7j 0SJ��60
a Addition: esida ce commercial If an Ad 'lion,what will use of ew addition be?
a Alteration: res Coco/ commercial / �.
a No change to exterior size: residence/com'1
o Other work(describe )
Check Occupancylnformation 1' FIoor 2° Floor other floor Total `3.y
Below sq.ft. sq.ft. sq.ft. Square Feet
Sine 'y dwelling �$'—
o fim3ily dweMn
a Townhouse
o Multifamily dwelling
#of units
a Office
a Mercantile
c Maaufacturin
c 1 car detached prage
0 2.car detached garage
a 3 car detached prage
1 oar attached garage W Ic7
o 2 oar attached garage J
0 3 car attached garage
o Storage building-
commercial
o Storage building-
residential
o Other
What is the proposed height of the structure feet inches
Will any second-hand or ungraded lumber be used? If so,for what? ?/e,
Type of Heating System: electric/ oil 1 01
wood /forced hot air/ baseboard/other:
Number of,-replaces to be installed Number of Woodstoves to be installed
List below the person(s)responsible for supervision of work as regards to building codes:
Name Address- Phone Number
Builder Sc!/ d b vY1 -e- sz,
Plumber
Mason
Electrician
Declaration please sip below after you have carefully read the statement:
To the best of my knowledge the statements contained in this application;together with the plans and specifications
submitted,are a true and complete statement of all proposed work to be done on the described premises and that all
provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied
with,whether specified or noted,and that such work is authorized by the owner, Further,it is understood that Uwe shall
submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning
Administrator or Director of Building and Codes,an As Built Survev by a licensed surveyor;drawn to scale,showing actual
location of all now construction
Signature: owner,owner's agent,architect,contractor
Queensbury Building & Code Enforcement - Residential Final Inspection /{
Office No. (,518)761-8256 Arrive: am/p art: m/pm
Date Inspection request received: Inspector's Initials.. `
NAME: PERMIT#: O r l
LOCATION: _.� DATE:
TYPE OF STRUCTURE.
Comments
Y N N/A r
Chimney Ht./"B"Vent/Direct Vent Location �1 r��� 1
Fresh Air Intake 1C -P
3 inch Plumb Vent through roof minimum 6" l
Roof Complete/Exterior Finish Complete
Guard 30 in.or more @ stairs,decks,patios
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in. or more
xterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock Underside minimum %"
Gypsum
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post or Wall
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft. or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: / Every Bedroom:
Outside every bedroom area:
Inter Connected: / Battery backup:
Carbon Monoxide Detector
Bathroom Fans, if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/'/4 hour fire door/door closer
itct work Sealed properly
as Logs in Sealed or Glass Enclosure -]z
Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area
Crawl S aces 18"x 24"access, I s . ft.-150 s . ft.vents
Building No./Address visible from road
Final Electrical
Site Plan /Variance required
Final Survey Plot Plan
As Built Septic System/Sewer Dept. Inspection Sticker
Flood Plain Certification, if required
Okay to issue C/C or C 10 Temporary/Permanent
L:\PamW\Building&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518)761-8256 /`, Arrive: am/p De art: a
Date Inspection request received: _T1-7x` i /lr') Inspector's Initials:
NAME: c, r ke,I T PERMIT#: Z00 '.14
LOCATION: Z,0 EAS ft-Al DATE: r7, AYOLY
TYPE OF STRUCTURE:
Comments
Y N N/
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6"
Roof Complete/Exterior Finish Com lete
Guard 30 in.or more 0 stairs,decks,patios
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in. or more
Exterior Finish Complete e
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock Underside minimum %z"
Gypsum
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post or Wall
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft. or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: / Every Bedroom:
Outside every bedroom area:
Inter Connected: / Battery backup;
Carbon Monoxide Detector
Bathroom Fans, if no window
Plumbing fixtures
Foundation insulation
Floor truss, draft stopping finished basement 1,000 sf
Emergency a Tess below grade
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/1/4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Attic access 30 in.x 22 in.x 30 in,(ht.)In accessible area
Crawl Spaces 18"x 24"Access, 1 s . ft.-150 s . ft.vents
Building No./Address jisibb fr m road
Final Electrical �-1
Site Plan /Variar;cerJqulifed
Final Survey Plot Plan
As Built Septic System/Sewer Dept. Inspection Sticker
Flood Plain Certification, if required
kay to issue C/C or C/O Temporary/Permanent
L:\PamW\Building&Codes\Inspection Forms\Res, Final Insp. form 2.docLast printed 2/12/04
Queensbury Building & Code Enforcement - Residential Final Inspection
e No.(518)761-8256 Arrive: am/
epart: f am/pm
Date Inspection request received: _ Inspector's Initials:
iftNAME: PERMIT#: 0 I l
LOCATION: DATE:
TYPE OF STRUCTURE:
Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6"
Roof Complete/Exterior Finish Complete
Guard 30 in.or more @ stairs,decks,patios
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in. or more
Exterior Finish Complete
Interior/Exterior Railings 34 in. to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock Underside minimum %"
Gypsum
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post or Wall
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft.or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors: ,/�j v
Every level: / Every Bedroom: 6 46 t/ d Nl l �
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Bathroom Fans, if no window
Plumbing fixtures A
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf 11
Emergency egress below grade
Basement stairs closed rise>4 inches
Garage Floor Pitched _
Garage fireproofing/'/4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, I s . ft.-150 s . ft. vents
Building No./Address visible from road
Final Electrical
Site Plan /Variance required
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Flood Plain Certification,if required
Okay to issue C/C or C/O Temporary/Permanent
L:\PamW\Buildinp,&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.Q(,
Main Office 176 Doe Run Road-Manheim,PA 17545
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
Permit No.....'6.............. .............Cert. 84731 Cut-in Card No........................�...
Owner............................................................ ���"(............ ..... ......
Location .......................................
o .. iV......... ' ......
` .............
.... ...... ........... ........................... . r. . .............
Installation Consisting of.. ..7• )-
.... ................................................................................
.................................................................................................................................................
Installed B ��. :L{l� .Lic.No........................
The conditions following governed the issuance of this certificate,and any certificate previously issued is
cancelled:-
This certificate only covers the electrical equipment and installation conditions as of date. Upon the
introduction of additional equipment or alterations,application sha a promptly made for inspection.
Inspectors of this Company shall have the privilege of m ing i spections at any time, and if it:
rules are violated,the Company shall have the right o r odlet
is cc ificat
lz- o 1 Date...... ..... .�................... INSPECTOR:..,...... ...: ....................................................................
t o C l
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received: A(
Queensbury Building& Code Enforcement Arrive: am/ epart:�4"' am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: ���"�-'�G`'� PERMIT#:
LOCATION: �— Co A—) INSPECT ON:
TYPE OF STRUCTURE:
Framing Y N N/A COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ic and snow shield 24 inches from wall
V/Fire separation 1, 2, 3 ho e-
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side '/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LASueFlemingway\BuiIding.Codes.Inspecti on.FORM S\Framing Firestopping Inspection Report.doc January 28,2003
LJ
Framing / Firestopping Inspection Report
Zc � CJ
Office No. (518) 761-8256 Date Inspection request received: I
Queensbury Building & Code Enforcement Arrive: am/ art: m/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials.
Au
NAME: C 0 PERMIT#: Z�� �l l7
LOCATION: N INSPECT ON: 7i�G
TYPE OF STRUCTURE:
C CAL
Framing Y N N/A COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2(w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
I and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
�-Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemin,way\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
� v
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received: e
Queensbury Building& Code Enforcement Arrive: am/p�n Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials. ��
NAME: rayAo4-A�A PERMIT#: . 0 7
LOCATION: INSPECT ON:
TYPE OF STRUCTURE
Framing :
Y N N/A COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall /
pa ion 1, 2, 3 hour
Fire s�
F wall 2, 3, 4 hour
irestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHerningway\13uiIding.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
Dough Plumbing / Insutlation In pection Deport
Office No. (518) 761-8256 Date Inspection reques ec ive
Queensbury Building& Code Enforcement Arrive: pm art: a
742 Bay Road, Queensbury,NY 12804 Inspector's Initial
NAME: �or PERMIT
LOCATION: 1-550� INSPECT ON: /o �, o
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1,R-2, R-3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 % inch min. Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
Cooper Commercial
C CPVC,Pex One and Two-Family
nsulatioj/ esidential Check/Commercial Check
ro er Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
L
LASueHemingway\Building.Codes.Inspection.FORM S1Rough Plumbing Insulation Report.doc Plovember 17,2003
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection reques ec i ed:
Queensbury Building& Code Enforcement Arrive: o D art: am/ m
742 Bay Road, Queensbury,NY 12804 Inspector's Init'als:
NAME: C, • .e- P 4 PERMIT #: LA
LOCATION: c� INSPECT ON:
TYPE OF ST UCTURE:
Y N N/A
PVC: R-1, R-2,R-3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/ Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 % inch min.. Drain Size
Washing Machine Drain 2 inch nun.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
Cooper Commercial
96o er, CPVC,Pex One and Two-Family
nsulation/Residential Check/ Commercial Check ,
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation P�
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properl /No duct toe ���QS,
COMMENTS:
L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003
V
7 a - j
?(,/
Framing / Firestopping inspection Report
Office No. (518) 761-8256 Date Inspection re uest re�6iQ: i
Queensbury Building& Code Enforcement Arrive: G - its (D��art:
742 Bay Road, Queensbury, NY 12804 Inspector's Ini via
i
NAME: IJ PERMIT#: C)
LOCATION: ,. INSPECT ON: -QL f
TYPE OF STRUCTURE:
Y N N/A COMMENTS
raming
J
Jack Studs/Headers
Bracing/Bridging
Joist hangers /
Jack Posts/Main Beams 1
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %z (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Airestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LASueHemingway\Building.Codes.Inspection.FORMSTraming Firestopping Inspection Report.doc January 28,2003
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request i — /(0 _� O
Queensbury Building & Code Enforcement Arrive: �t�arn/p e�p rt: am/_
742 Bay Road, Queensbury, NY 12804 hispector's Initials---_
NAME: �� PERMIT#: ! {
LOCATION: — INSPECT ON: oZC'� G
TYPE OF STRUCTURE:
Y Iv lv/a.
Framing ) COMMENTSCOMMENTSJack Studs/Headers
Bracing/Bridgingn_��p
Joist hangers
Jack Posts/Main Beams ����� ���� ��t7 L �Nt�
Exterior sheeting nailed properly —�12 O.C. \��y
CJ� 7�
Headroom 6 ft. 8 in. _
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %z (w) 16 gauge (8) 16D nails each side _
Draft stopping 1,000 sq. ft. floor trussesLl
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side % inch or 5/8 inch Type X �a tz)
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H) t�
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Voc `� e
L:\SueHemineway\Building.Codes.lnspection.FORM S\framing Firestopping.Inspection Repo t.doc
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/p I Depart. am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: Q � PERMIT#:
LOCATION: _ ('7 �G�oti�nr. t�� INSPECT ON: C
TYPE OF STRUCTURE:
Y N NSA COMMENTS
Framin 7
Jack Studs eaders
Bracing/ ridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %z (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %a inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemingway\Building.Codes.Inspection.FORMS\framing Firestopping Inspection Report.doc January 28,2003
j
Foundation Inspection Report
Office No. (518) 761-82.56 Date Inspection request received:
Queensbury Building&.Code Enforcement Arrive: anvp Depart: ej - nVpm
742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: —
NAME: _ PERMIT#: � y9Y 7
LOCATION: _ O�- _ INSPECT ON: �L/
TYPE OF STRUCTURE: G
Comments
footings ,---- -- --
Piers
Monolithic Slab
Reinforcement in Place -2 : "*
The contractor is responsible for q
providing protection from freezing
for 48 hours following the placement IPaV[�Cig ��05 �20
of the concrete.
Materials for this purpose on site, LEe�v/J AT
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
LASucHlcmingway\Building.Codes.Inspection.FO WSW oundation Inspection Report.doc January 28,2003
Foundation n a i Ins Report �Inspection
Office No. (518) 761-82.56 Date Inspection request received:
Queersbury Building&Code Enforcement Arrive: anvil Depart: anVpm
742 Bay Rd'.; Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT#: 4LI
LOCATION: _ cl INSPECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete. —
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation./Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 r poly for wet areas under slab
ill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R- _
Rough Grade 6 inch drop within 10 ft.
L:\SucHemingway\Building.Codes.Inspection.FO RMSToundati on Inspection Report.doe January 28,2003 .
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection re est re ei d: i
Queensbury Building&Code Enforcement Arrive: iv pm epart: is m
742 Bay.Rd., Queensbury,:NY 12804 Inspector's Initia
NAME: ( _ '�, 1IT#: i �
LOCATION: _ �II�ISPECT ON:
TYPE. OF STRUCTURE:
Comments
Y Iet N/A
ootings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this pu_pr ose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
LASuel-Icmingway\Building.Codes.Inspcction.FURMSToundation Inspection Report.doc January 28.2003
R E C 'V
JtI � ®CT .! 1995
TOWN p� TOV* y��t : :r
4
i4R.•
i
N
si,`, • `mot .Q4l D c\LJf�
� : 91 .75'
Permit Numb&
RECE V
MECcheck Compliance Report Checked By/Date J."N 1, 7 200�TOWN OF
Proposed New York State Energy Conservation Construction Code OVVIV UEENSBL
MECcheck Software Version 3.3 Release lb AND•COD,
Data filename:C:\Program Files\Check\MECcheck\CORBET.cck
TITLE:CORBET RESIDENCE
COUNTY:Warren
STATE:New York
HDD:7635
CONSTRUCTION TYPE:Detached 1 or 2 Family
HEATING TYPE:Non-Electric
DATE:06/16/04
DATE OF PLANS:02-28-04
PROJECT INFORMATION:
CORBET RESIDENCE ADDITION
EAGEN ROAD
QUEENSBURY,NY 12804
COMPLIANCE:Passes
Maximum UA=201
Your Home=181
10.0%Better Than Code
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1:Flat Ceiling or Scissor Truss 360 38.0 0.0 11
Ceiling 2: Cathedral Ceiling(no attic) 205 30.0 0.0 7
Wall 1:Wood Frame, 16"o.c. 730 19.0 0.0 44
Wall 2:Wood Frame, 16"o.c. 304 19.0 0.0 7
Window 1:Vinyl Frame,Double Pane 134 0.470 63
Door 1: Solid 20 0.069 1
Door 2: Glass 40 0.470 19
Basement Wall 1:
Solid Concrete or Masonry,8.0'ht/7.0'bg/8.0'insul 512 0.0 11.0 29
Furnace 1:Forced Hot Air,92 AFUE
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building
plans,specifications,and other calculations submitted with this permit application. The proposed systems have been
designed to meet the Pro sed Ne York StMEnConservation Construction Code rX/�Ch
' ements.
�� 5F N,-IV yBuilder/Designer �. I �� Date (a ��' p KEITy 09
m ,.. Uj
c� 066 5?
� FSON
MECcheck Inspection Checklist a
Proposed New York State Energy Conservation Construction Code '
MECcheck Software Version 3.3 Release lb
DATE:06/16/04
TITLE:CORBET RESIDENCE
Y
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation
Comments:
[ ] 2. Ceiling 2:Cathedral Ceiling(no attic),R-30.0 cavity insulation
Comments:
Above-Grade Walls:
[ ] 1. Wall 1:Wood Frame, 16"o.c.,R 19.0 cavity insulation
Comments:
[ ] 2. Wall 2:Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
Basement Walls:
[ ] 1. Basement Wall 1: Solid Concrete or Masonry,8.0'ht/7.0'bg/8.0'insul,
R-11.0 continuous insulation
Comments:
Exterior insulation must have a rigid,opaque,weather-resistant protective covering that
covers the exposed(above-grade)insulation and extends at least 6 in.below grade.
Windows:
[ ] 1. Window 1:Vinyl Frame,Double Pane,U-factor:0.470
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? [ ]Yes[ ]No
Comments:
Doors:
[ ] 1. Door 1: Solid,U-factor: 0.069
Comments:
[ ] 1 2. Door 2:Glass,U-factor:0.470
##Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
Heating and Cooling Equipment:
[ ] 1. Furnace 1:Forced Hot Air,92 AFUE or higher
Make and Model Number
Air Leakage:
[ ] Joints,penetrations,and all other such openings in the building envelope that are.sources of air
leakage must be sealed.
[ ] Recessed lights must be Type IC rated and installed with no penetrations,or Type IC or non-IC
rated installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible
materials and 3"clearance from insulation.
Vapor Retarder:
r
[ ] I Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
I
Materials Identification:
[ ] I Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] I Materials and equipment must be identified so that compliance can be determined.
[ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating
I equipment must be provided.
[ ] I Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on
I the building plans or specifications.
I
Duct Insulation:
[ ] I Supply ducts in unconditioned attics or outside the building must be insulated to R-11.
[ ] I Return ducts in unconditioned attics or outside the building must be insulated to R-6.
[ ] I Supply ducts in unconditioned spaces must be insulated to R 11.
[ ] I Return ducts in unconditioned spaces(except basements)must be insulated to R 2.
Insulation is not required on return ducts in basements.
I
Duct Construction:
[ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics
I (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted.
Exception:Continuously welded and locking-type longitudinal joints and seams on ducts
I operating at less than 2 in.w.g.(500 Pa).
[ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] I Air filters are required in the return air system.
[ ] I The HVAC system must provide a means for balancing air and water systems.
I
Temperature Controls:
[ ] I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
I temperature set point of the largest zone.
I
Electric Systems:
[ ] I Separate electric meters are required for each dwelling unit.
I
Fireplaces:
[ ] I Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[ ] I Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
I provisions of the Building Code of New York State,the Residential Code of New York State or
the New York City Building Code,as applicable.
I
Service Water Heating:
[ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
I water heater has an integral heat trap or is part of a circulating system.
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
Circulating Hot Water Systems:
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
Swimming Pools:
[ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
I of the heating energy is from non-depletable sources. Pool pumps require a time clock.
I
Heating and Cooling Piping Insulation:
[ ] I HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
I levels in Table 2.
-..,
dow-
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) Un to 1„ Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0. 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD(Building Department Use Only)