blower door reportTesting Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@locascioenergysolutions.com Building Information: Project ID:5 Whispering Address:5 Whispering Pnes Way Queensbury, NY 12804 Geo-Tag Data:Latitude: 43.316029 Longitude: -73.725611 Timestamp: 2021-03-31 12:39:45 Customer Information: Name:Caruso Home Builders Address: Measured Leakage:1,912.6 CFM50 Test ID:5 Whispering Purpose of Test:50 Pa Env. Leakage Measured ACH50:2.90 Effective Leakage Area: 105.2 in² Building Volume:39,577.0 ft³Enclosure Surface Area: 4,383.0 ft² Coefficient (C):150.4 Exponent (n): 0.650 (assumed) Test Standard:RESNET 380 One-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 62 °F Altitude: 384.0 ft Outdoor Temp: 60 °F Time Average Period: 10 seconds Test Date and Time:2021-03-31 13:05:00 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -4.3 -50.0 -59.3 -55.0 -130.8 2,046.6 Ring A Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3173 Custom Calibration Date: 2021-02-10 Pressure Gauge:DG1000 Serial #: 5193 Calibration Date: 2020-01-16 Deviations from Standard: None Comments: None Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.7.3 (91), © 2020 The Energy Conservatory, Inc.