Signed Inspection Report (Wed Mar 31, 2021 at 1217 PM)INSPECTION WORKSHEET (FDTN-009279-2021)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0159-2020 Case Module:Permit
Inspection Date:Wed Mar 31, 2021 Inspection Status:Partial Pass
Inspector:Dyer, Charles Inspection Type:Building Foundation
Job Address:Parcel Number:537 State Rte 149
Lake George, NY, 12845
278.-1-34
Contact Type Company Name Name
Insulation Contractor JMR Irish Drywall Inc
Applicant Hitchcock, Stephen
HVAC Del's Plumbing
Primary Owner Hitchcock, Sabrina
Primary Owner Hitchcock, Stephen
Engineer Jensen, Peter
Contractor ACW Family Builders
Granted Permission Hitchcock, Stephen
Checklist Item Status
Building Inspector Notes Failed
1/14/21 footings approved, provide an updated plan showing the change in the vertical dowels from J hook to
straight #4 rebar, 4' on center, one foot from each corner.
Please have the stamped plans on site for inspection.
2/5/21 as discussed, place plans and permit card in weather protection box @ meter panel
3/19/21 footings for garage approved, 3 rows of #4 rebar continuous, vertical dowels to be wet set.
3/22/21 poly under slab at basement verified
Footings Passed
Mar 31, 2021 Page (1)
INSPECTION WORKSHEET (FDTN-009279-2021)
Checklist Item Status
Footings approved, 3 rows of #4 rebar continuous
Piers Passed
Piers approved at basement, 3 #4 rebar each direction
Monolithic Slab Failed
Reinforcement in Place Passed
3 rows of #4 rebar continuous
Foundation / Wallpour Passed
For garage wall 3/31/21 with one row continuous top
Reinforcement in Place Passed
Reinforcement in Place Failed
Footing Dowels or Keyway in place Passed
Foundation Dampproofing Passed
Approved 2/5/21
Footing Drain Daylight or Sump Failed
Footing Drain Stone - 12 inch width Passed
Footing Drain Stone - 6 inches above footing Passed
Mar 31, 2021 Page (2)
INSPECTION WORKSHEET (FDTN-009279-2021)
Checklist Item Status
Backfill Approval Passed
Plumbing Under Slab Failed
PVC / Cast / Copper Failed
Foundation Insulation Interior / Exterior Failed
Rough Grade 6 inch drop within 10 ft.Failed
Poly Under Slab Passed
3/22/21 poly under slab at basement verified
Mar 31, 2021 Page (3)
Dyer, Charles