Signed Inspection Report (Fri Apr 2, 2021 at 146 PM)INSPECTION WORKSHEET (BINS-009356-2021)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:CC-0228-2019 Case Module:Permit
Inspection Date:Fri Apr 2, 2021 Inspection Status:Partial Pass
Inspector:O'Brien, John Inspection Type:Building Insulation
Job Address:Parcel Number:1447 RIDGE RD
Queensbury, NY, 12804
279.-1-50
Contact Type Company Name Name
Granted Permission Baldwin, Dale
Contractor Baldwin, Dale
Primary Owner Baldwin, Dale
Applicant Baldwin, Dale
Checklist Item Status
Permit Card Visible From Road Passed
15 min thermal barrier/intumescent paint applied - to open spray foam Failed
Apr 02, 2021 Page (1)
INSPECTION WORKSHEET (BINS-009356-2021)
Checklist Item Status
Building Inspector Notes Failed
12/15/20 Building Insulation Partial Approval
- Proper Vent w/ baffle approved
2/3/21 Building Insulation Partial - Ceiling Only!
- Ceiling Insulation Approved R38 main dining area and 2nd floor office
3/23/21 Building Insulation Partial Approval
- Upper Front Elevation Wall in dining area approved.
R26 (two layers of R13 with a kraft paper vapor barrier).
Window Sealing Failed
U Factors = .3 cfm for windows, .5 cfm for doors Failed
Tyvek or Similar Exterior Sealant Failed
Proper Vent, Attic Vent Passed
12/15/20 Building Insulation Partial Approval
- Proper Vent w/ baffle approved
Apr 02, 2021 Page (2)
INSPECTION WORKSHEET (BINS-009356-2021)
Checklist Item Status
Insulation Residential Check Commercial Check Passed
12/15/20 Building Insulation Partial Approval
- Proper Vent w/ baffle approved
2/3/21 Building Insulation Partial - Ceiling Only!
- Ceiling Insulation Approved R38 main dining area and 2nd floor office
3/23/21 Building Insulation Partial Approval
- Upper Front Elevation Wall in dining area approved.
R26 (two layers of R13 with a kraft paper vapor barrier).
3/25/21 Building Insulation Partial Approval
- Upper Elevation Balance of dining area walls approved.
R26 (two layers of R13 with a Kraft paper vapor barrier).
4/2/21 Building Insulation Partial Approval
- Lower Exterior Walls in ding area approved(two layers of unfaced R13 with 6 mil poly)
Blower Door Test Failed
Combustion Air Supply for Furnace Failed
Fresh air supply 3' from grade Failed
Duct Insulation - if required in unheated spaces Failed
Door / Window Sealed (No Insulation)Failed
Apr 02, 2021 Page (3)
INSPECTION WORKSHEET (BINS-009356-2021)
Checklist Item Status
Tub Shower R-20 with Vapor Barrier Failed
Air Barrier behind Knee Walls Failed
All Ductwork Sealed Return and Supply Failed
Duct Blaster Test for duct work, R-8 Failed
All Return Air Hard Duct Work Failed
House Wrap Taped at all Seams Failed
Apr 02, 2021 Page (4)
O'Brien, John