Loading...
2007-226 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF COMPLIMN- CE Permit Number. P20070226 Date Issued: Monday, May 19, 2008 This is to certify that work requested to be done as shown by Permit Number P20070226 has been completed. Tax Map Number. 523400-308-010-0001-062-000-0000 Location: 5 WAYNE Ct Owner. JEFFREY & KERRY ZIEGLER Applicant: JEFFREY & KERRY ZIEGLER This structure may be occupied as a: Deck By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, VVV Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5902 (518) 761-8201 Community Development -Building & Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20070226 Application Number. A20070226 Tax Map No: 523400-308-010-0001-062-000-0000 Permission is herebygranted to: JEFFREY & KERRY ZIEGLER For property located at: 5 WAYNE Ct in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tvne of Construction Value Owner Address: JEFFREY & KERRY ZIEGLER Deck $2,600.00 $ WAYNE Ct Total Value $2,600.00 QUEENSBURY, NY 12804 Contractor or Builder's Name /Address Electrical Inspection Agency Plans & Specifications 2007-226 437 sq ft deck $43.70 PERMIT FEE PAID -THIS PERMIT EXPIRES: Saturday, May 17, 2008 (If a longer period is required, an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To eens u da May 17, 2007 SIGNED BY ' Y for the Town of Queensbury. Director of Building & Code Enforcement Z FFICE USE ONLY ." '~ "" ' ' R ;TAX MAP NO. PERMIT NO.~ ~ ~~--~2 ~ ~ FEE PAID , BLDG. & CODES APPROVAL " ,° " ~ ' ' ~ ; ___________________ ODE ; ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION Use this application for any structure other than the Principal Structtare (house) to include, but not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures-Sheds/Fences. A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. OWNER: ~~ ~~~,Y ~ ~~~ INSTALLER/BUILDER: cS ~(_~ ADDRESS: ~~ 1il/}W N ~ C ` ~-,~,e~~ ADDRESS: PHONE NOS. ~"I ~ - I ( J t'T'1 O r 4IG1 J"'r~j ~9 PHONE NOS. LOCATION OF PROPERTY: 1_) `~ V 7 ~~ ~~~~~f SUBDIVISION NAME: ~"C~1-t-L~ ~. V ~LL~ LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: ~~ ~j ~ {~ J~ ESTIMATED COST OF CONSTRiU~CTION: $~~ ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? ~I FS IF YES, PLEASE LIST: Jr- ~ ~I 1 CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: ~!E~ZRy Z. ~ ~(-~ L ~~Z PHONE: 7`7 ~- ~(~ / PROPOSED CONSTRUCTION 1'T FLOOR 3Q. FT. 2ND FLOOR SQ. FT. TOTAL SQ. FT. PROPOSED HEIGHT FT. & IN. OPEN PORCH DECK 3 SEASON, COVERED OR ENCLOSED PORCH• BOATHOUSE BOATHOUSE WITH SUNDECK DOCK SHED POLE BARN DETACHED GARAGE (NO.OF CARS: ) OTHER ACCESSORY STRUCTURE: *CONSIDERED FLOOR AREA & MUST COMPLY WITH FAR [FLOOR AREA RATIO] REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy Or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all new construction. QUESTIONS ? CALL 761-8236 OR EMAIL ~ I have read and agree to the above. codesCa~aueensburv.net ~ VISIT OUR WEBSITE FOR MORE INFORMATION Signed Dated: www.aueensburv.net Tozvn of Queenshury • Community Development Office • 742 Bay Road, Queenslrury, NY' .12804 B 1-LGL it-OS Foundation Inspection Report Office No. (518) 761-8256 Date Inspection Queensbury Building & Code Enforcement Arrive: ~~Q 742 Bay Rd., Queensbury, NY 12804 Inspector's Initi~ NAME: Z 1 ECG ~E.PI LOCATION: ,5- ~ A ~~ ~T" TYPE OF STRUCTURE: Depart: ~=dam/ m ON: ~.~ - \ -p~ Comments Y N N/A Footings ti~ Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this on site. Foundation / Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil 1 for wet areas under slab Backfill Approval Plumbing Under Slab PVC /Cast /Copper Foundation Insulation Interior /Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building & Codes Forms\Building & Codes\Insp~don Forms\Foundaiion Inspection Reportdoc last printed 12/20/2005 9:24:00 AM Framing /Firestopping Inspection Office No. (518) 761-8256 Date Ins ection ~ Queensbury Building & Code Enforcement Arrive: 742 Bay Road, Queensbury, NY 12804 Inspector's Initia. NAME: E t_E(Z LOCATION: cS t~~ A ~r (' ~r Z~ TYPE OF STRUCTURE: Y N NJA Framing Attic Access 22" x 30" minimum Jack Studs /Headers Bracing /Bridging Joist hangers Jack Posts /Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches /Holes /Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w 16 au e 8 i 6D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wa112, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavi min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilin wall Windows Habitable Space /Bedrooms 24 in. (H) 20 in. (V~ 5.7 sf above /below grade 5.0 sf ade ,, ~, {r a m ( /~ PERMIT #: ,.. INSPECT ON: - - COMMENTS '"~ ~ " `v , Queensbury Building & Code Enforcement -Residential F~al,k>yspection Office Nta. (518) 761-8256 Arrive: _ a Date Inspection request received: Inspector's Initials: NAME: PE LOCATION: __ r~e~_ DI TYPE OF STRUCTURE: Y WA 4" Buildi Number Address visible from road Chim / "B" Vent/Dired Vent Location Frssh Air Intake 3 irx;h Plumbi Vent th h roof minimum 6 inc~es Roof !Exterior Finish Com Platform at all exterior doors Handrail 4 a more risers Guards at stairs decks, more than 30 indres above tads Guard at stairwell at 34 inches or more Guard at deck, rches 36 inches or more Handrail Termination at Newell Post or Wall Irterior/6derior Rai' 34 ind~es ba 38 irx~es Deck Brad /Hand' Ra Com ' nt Grade from foundation 8 inches with 10 feet 8 inch dearance to sill Gas Valve shut-ofF / ulator 18 ind~es above Interior / trttn /doors /main entrance 36 inches Bathroom ! ICtdren wale ' ht ' /window in stainnregs Interior Smoke Detectors /Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: B badw Attic aooass 30 irK;hes x 22 irx;hes x 30 indres it acoassible area Crawl S 18 inch x 24 inch access 1 . ft: 150 . ft. vents Bathroom Fans if no window Plum ' factures Foundation insulation Floor truss draft st finished basement 1.000 . ft. E below Gas Furnace shut-off wither 30 feet a within tine of site Oit Furnace shut-off at entrance to furnace area FumaceMot Water Heater o Low water shut-off boiler Relief Va s installed /Heat Tra Water Te 110 En+dosed Stairs Sheetrock Underside minimum'r4' G m Basement stairs dosed rise > 4 irx~es e Floor Pild~ed Ga e fi /'/. hour fire door / door doser Dud work Sealed Gas in Sealed or Glass Enclosure Final Electrical Final Surve Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pi Bond' As Built 'c S em /Sewer De .Ins Sticker Site Plan /Variance 'red Fkxxi Plain Certification, if wired O to issue C / C or C / O Tem ! Pernanerrt ,~ rt: 1,~ rrv #; Comments J/ L:~Building 8~ Codes Fornsl6uilding & Coc~sVnspek~ion FormsV2ssidential Final Inspection Form revised_100405.doc; Revised January 7, 2008 O co J .:~ c ~ ~. ~ ~ x ~ a -~ v~ Tom 1~=~-. 3p 8 ~ la- t--(o2 _ -_ --- . ~3 N 326'01" E 163.29' ~ W ~ ~ ~ ~ ~ ~~~" r R` ~' l,~l ~ ~. ~. 5 `~\,~ `• Q ~.,~~~ O J, .~- f _~~ . N _------ c~ ~+ ONO ~ `~ / ~,K ,A ~. O 5~ ~ • w -~ s , ~ A O~ ~~9' ~~~ ~~. `'~ R 204.1 ~,, '~ 8a• ~' `;; ,~ i ~' C.T.V ~ I ~ 5~~5 ~ ~ t 5 01. _ _ - ti ~e ,een or o'oserved, or believe I saw evidence of, }! ~,i;lP~ts such as houses, v~ells, trees, fences, etc., ~~ ~~,~fr~ orr this document. I aisa represent that I have ~cH ~` 1 ~. ~~ :1 ~ ~~ ~_~ ~... .~zt~'ionaily measured the distance t forth on the diagram." - r_n~nTr DATE T 0'~-2z~