JB201133.0134.Concrete Compressive Strength Test.2021-03-29.Rpt.0134Report Number: Service Date: Report Date: Task: Client Queensbury, NY 12804 Bay Road and Blind Rock Road Fowler Square SI and CMTRosetti Acquisitions LLC Attn: Christopher Falvey 427 New Karner Rd Albany, NY 12205 518-266-0310 Albany, NY 12203-5169 30 Corporate Cir Ste 201 JB201133.0134 03/29/21 04/08/21 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Project Project Number: JB201133 Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: C40R762 Craneville Block Company Material Information 0630 487 Plant: Ticket No.: 18 1835673 Field Test Data Test Air Content (%): Result Specification 8 6 - 8 1.2 0 - 3 69 45 - 90 37 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:03/29/21 0730 Bryan Smith Overcast and Windy 10 10 Point of PlacementSample Location: Placement Method:Chute Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Slab on Grade between column lines 13 and 18 Placement Location: Laboratory Test Data Set Avg Diam.Area Weight DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) Tested By(lbs) 1 A 4.00 12.57 03/30/21 8.95 04/05/21 7 62,830 2 5,000 ADV 1 B 4.00 12.57 03/30/21 8.90 04/26/21 28 1 C 4.00 12.57 03/30/21 8.90 04/26/21 28 1 D 4.00 12.57 03/30/21 8.95 04/26/21 28 1 E 03/30/21 8.85 Hold 1 F 03/30/21 8.85 Hold Initial Cure:Final Cure:Onsite Cooler Moist Room Comments:Not tested for plastic unit weight. Super-P added Samples Made By: Dente Group - A Terracon Co. Sample fresh concrete at the placement locations, perform required field tests and cast compressive strength samples.Services: Reported To: Contractor: Report Distribution: (1) Rosetti Acquisitions LLC, Christopher Falvey (1) 260 Structural Engineering, Dan Thomas (1) BBL Construction Services, Bobby Chatterton (1) BBL Construction Services, Eric Weatherwax (1) BBL Construction Services, Ryan Etue (1) D.A. Collins Construction Co Inc, Robin Stothers (1) Galusha & Sons LLC, Drew Stevens (1) Galusha & Sons LLC, James Campagnone Bobby w. BBL ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Dente Group - A Terracon Co. Rep.: Bryan Smith The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 3CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Queensbury, NY 12804 Bay Road and Blind Rock Road Fowler Square SI and CMTRosetti Acquisitions LLC Attn: Christopher Falvey 427 New Karner Rd Albany, NY 12205 518-266-0310 Albany, NY 12203-5169 30 Corporate Cir Ste 201 JB201133.0134 03/29/21 04/08/21 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Project Project Number: JB201133 Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: C40R762 Craneville Block Company Material Information 0830 628 Plant: Ticket No.: 18 1835679 Field Test Data Test Air Content (%): Result Specification 7 1/2 6 - 8 0.5 0 - 3 65 45 - 90 39 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:03/29/21 0930 Bryan Smith Sunny and Windy 60 10 Point of PlacementSample Location: Placement Method:Chute Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Slab on Grade between column lines 13 and 18 Placement Location: Laboratory Test Data Set Avg Diam.Area Weight DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) Tested By(lbs) 2 A 4.00 12.57 03/30/21 8.90 04/05/21 7 63,030 2 5,020 ADV 2 B 4.00 12.57 03/30/21 8.85 04/26/21 28 2 C 4.00 12.57 03/30/21 8.85 04/26/21 28 2 D 4.00 12.57 03/30/21 8.90 04/26/21 28 2 E 03/30/21 8.85 Hold 2 F 03/30/21 8.90 Hold Initial Cure:Final Cure:Onsite Cooler Moist Room Comments:Not tested for plastic unit weight. Super-P added Samples Made By: Dente Group - A Terracon Co. Sample fresh concrete at the placement locations, perform required field tests and cast compressive strength samples.Services: Reported To: Contractor: Report Distribution: (1) Rosetti Acquisitions LLC, Christopher Falvey (1) 260 Structural Engineering, Dan Thomas (1) BBL Construction Services, Bobby Chatterton (1) BBL Construction Services, Eric Weatherwax (1) BBL Construction Services, Ryan Etue (1) D.A. Collins Construction Co Inc, Robin Stothers (1) Galusha & Sons LLC, Drew Stevens (1) Galusha & Sons LLC, James Campagnone Bobby w. BBL ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Dente Group - A Terracon Co. Rep.: Bryan Smith The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 3CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Queensbury, NY 12804 Bay Road and Blind Rock Road Fowler Square SI and CMTRosetti Acquisitions LLC Attn: Christopher Falvey 427 New Karner Rd Albany, NY 12205 518-266-0310 Albany, NY 12203-5169 30 Corporate Cir Ste 201 JB201133.0134 03/29/21 04/08/21 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Project Project Number: JB201133 Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: C40R762 Craneville Block Company Material Information 1000 659 Plant: Ticket No.: 18 1835684 Field Test Data Test Air Content (%): Result Specification 7 6 - 8 1.2 0 - 3 65 45 - 90 41 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:03/29/21 1030 Bryan Smith Sunny and Windy 110 10 Point of PlacementSample Location: Placement Method:Chute Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Slab on Grade between column lines 13 and 18 Placement Location: Laboratory Test Data Set Avg Diam.Area Weight DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) Tested By(lbs) 3 A 4.00 12.57 03/30/21 8.90 04/05/21 7 57,180 2 4,550 ADV 3 B 4.00 12.57 03/30/21 8.90 04/26/21 28 3 C 4.00 12.57 03/30/21 8.85 04/26/21 28 3 D 4.00 12.57 03/30/21 8.90 04/26/21 28 3 E 03/30/21 8.95 Hold 3 F 03/30/21 8.90 Hold Initial Cure:Final Cure:Onsite Cooler Moist Room Comments:Not tested for plastic unit weight. Super-P added Samples Made By: Dente Group - A Terracon Co. Sample fresh concrete at the placement locations, perform required field tests and cast compressive strength samples.Services: Reported To: Contractor: Report Distribution: (1) Rosetti Acquisitions LLC, Christopher Falvey (1) 260 Structural Engineering, Dan Thomas (1) BBL Construction Services, Bobby Chatterton (1) BBL Construction Services, Eric Weatherwax (1) BBL Construction Services, Ryan Etue (1) D.A. Collins Construction Co Inc, Robin Stothers (1) Galusha & Sons LLC, Drew Stevens (1) Galusha & Sons LLC, James Campagnone M. McHenry Materials Department Manager Bobby w. BBL Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Dente Group - A Terracon Co. Rep.: Bryan Smith The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 3CR0001, 11-16-12, Rev.6