Loading...
2004-813 TOWN OF QUEENSBURY 0.7 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20040813 Date Issued: Thursday, July 21, 2005 This is to certify that work requested to be done as shown by Permit Number P20040813 has been completed. Tax Map Number: 523400-239-012-0002-037-000-0000 Location: 33 HOLLY Ln Owner: BRIAN HOGAN Applicant: BRIAN HOGAN This structure may be occupied as a: Garage - 3 Cars Detached Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY ` 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040813 Application Number: A20040813 Tax Map No: 523400-239-012-0002-037-000-0000 Permission is hereby granted to: BRTAN HOGAN For property located at: 33 HOLLY Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. ' '1 Type of Construction Value Owner Address: BRIAN HOGAN 34 HOLLY Ln Garage-3 Cars Detached LAKE GEORGE, NY 12845-0000 Residential Addition $40,000.00 Total Value $40,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency MCCALL CONSTRUCTION 1485 CTY RTE 29 NORTH CREEK_ NY 12853-0000 • Plans&Specifications 2004-813 805 SQ FT 3-CAR DETACHED GARAGE WITH 529 SQ FT ADDITION $155.50 PERMIT FEE PAID THIS PERMIT EXPIRES: Tuesday, November 01, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T Queen ; oiday,November 01, 2004 SIGNED BY ` for the Town of Queensbury. Director of Building&Code Enforcement Building Permit Application Town of Queensbury—Dept of Community Development,742 Bay Road,Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. Permit File No.t _ — No inspection will be made until applicant has received a Fee Paid $ t.S T• D t e valid building permit. All applicants' spaces on this. Rec.Fee Paid $ �� applioation must be completed and must appear on the Reviewed By: application form. • ' Applicant: i Arr 14 Pr) Owner: S Address: 33. \- (,, .r Address: • Phone#( ) - cdb ' Phone#( ) Property Location: Lot Number: VHouse Number --', a39 Subdivision Name: /L 276 , ilb k''r- T p Number: — 3? New Building: residence /commercial 'Estimate t Value of Construction: $ 4401000 IS Addition: residence/ commercial : If an Addition,what will use of new addition be? !a Alteration: residence/ commercial 0 No change to exterior size: residence/com'l • i a Other work(describe ) Check Occupancylnformation 1"Floor 2°d Floor Other floor Total Below sq.ft. sq.ft, sq.ft. Square Feet ea Single flunily dwelling S 2- a Two family dwelling _ a Townhouse a Multifamily dwelling #of units a Office a Mercantile a Manufacturing • 0 1 car detached garage -0 2 car detached prage ®i 3 car detached garage.. .. a-t a u a 1 car attached garage 20a: 0 2 oar attached garage p C i 1 a 3 car attached garage IccNSBUM a Storage building- -TOWN A D CUuE commercial - UIt5 - Storage building- residential ., a Other • What is the proposed height of the structure ..l 6 feet 1) inches Will any second-hand or ungraded lumber be used? If so,for what? LA) Type of Heating System: electric/ oil / gas/wood /forced hot air/ baseboard/other: Number ofr1reotaces to be installed Number of Woodstoves to be installed List below the person(s)responsible for supervision of work as regards to building codes: Name- Address, Air. Number Builder ��e,'1� • V" j- ! !.'ru 'i 9 �. . //'il —3 J g Plumber Z eN k F©,VG, °OR 44-41). Y, J9.Li- 798 2G 9' Mason CiKe ECk in ,R v;�nilK.Fa`�ls i;. Ff)nn 79a -1E71 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 " IIrIIC)(PAL CERTIFICATE - ELECTRICAL APPROVAL GO f lf. F Permit No. Cert. No 9 017 6 Cut-in Card No. Owner Location i , :�-�,Y �,7' Inst �� ... / ?-7 1//Il�ayt{ion:4 ((/Consis//�� 1ti/n�gr of.g�1...CN/��'�)�� Installed By L--®,V Lic.No. The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be pro ptly made for inspection. Inspectors of this Company shall have the privilege of making ' spe 'ions at any time, and if its rules are violated,the the Company shall have the right to ke this ' mate.' Date 7-- " a INSPECTOR / nml.nv N GP A l A G V..,//, 1 Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/ . e rt: - 'y am/pm Date Inspection request received: 7/7 %( Inspector's Initials: G- LOCATION: 'NAME: 1-1 O U 1 L %�P DATE: TYPE OF STRUCTURE: 6/44Q #: 0 / , Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake /1/; 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete f Guard 30 in.or more @ stairs,decks,patios �j Guard at stairwell at 34 in. or more ✓ Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. �/� Platform at all exterior doors _ t/ Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" 1 Gypsum 17) Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall i � 6 inch clearance to sill plate ✓ Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 . /ti Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window I Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces I8"x 2 "acc ss, 1 sq. ft.-150 sq. ft.vents , Building No./Addre s v'si le fr road Final ElectricalSite Plan /Variani q ed Final Survey Plot Pan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Ce •.i1 Son, if required Okay to issue C/C C/0 [Temporary/Permanent] L:\PamW\Building&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/ epart: L.-, . m/p/ 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: QDc r�.l,� PERMIT #: 0 t — 3 LOCATION: �� l�� ' C INSPECT ON: — TYPE OF STRUCTURE: Y N N/A �t Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test 1, � Water Supply Piping W A Gt, R Air/ Head 59 P.S.I for 15 minutes C '7; /C/ 6 \ -f sulation / Residential Check/ Commercial Check Proper Vent, Attic:Vent V Duct/ Hot Water Piping Insulation If required unheated spaces .. Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 /o /i ._ Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: i Queensbury Building& Code Enforcement Arrive: arn/p�pert: 1 pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: 6 Gkd PERMIT#: 6414` (j LOCATION: ; cneJ_`/ C-a) INSPECT ON: D 5- TYPE OF STRUCTURE: • / _:/ :_ N/A Framing COMMENTS Jack Studs/Headers R6'611K_, Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.lnspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing /0. — Fr a g / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: arn/p n epa • D am/pm - iio 742 Bay Road, Queensbury, NY 12804 Inspector's Initials`.--:. r` /� r (s, NAME: 1 0v PERMIT#: dr \) t `3 f_____)'7 ..._. LOCATION: INSPECT ON: —� ILONS TYPE OF STRUCTURE: Y N /A COMMENTS ' piing.: —� Jack Studs/Headers Bracing/BridgingCat---,PC671— i/e 0 14' 1' Joist hangers Jack Posts/Main Beams 1L C� Exterior sheeting nailed properly sl �¢ D L��2 I / S 12"O.C. Headroom 6 ft. 8 in. 0 "Rik-ti," \ 1" Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour / jAffewall 2, 3, 4 hour topping,'. . i Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade l R6_4. . _R_kx.e) L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Fires pping Inspection Report.doc January 28,2003 Pge7/9 C�- ./1 1 Y Foundation Inspection Report P P Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: anvpm� epart: ,_ am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: /46•.fN PERMIT#: V -6(--. LOCATION: 3 , do c.�Y LAt/ • _ INSPECT ON: /1 be /0 • TYPE OF STRUCTURE: Comments Y N N/A • Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing nil poly for wet areas under slab ackfill Approval moing.Under SIab PV''/Cast/Copper G_-D 0 Foundation Insulation Interior/ exterior R- Rough Grade 6 inch drop within 10 ft. ,k,:\Suellcmingway\Building.Codes.lnspection.FORMS\Foundation nsp ' n Report.doe January 28,2003 :r2ROIV .Tier C f d _ q p ri.___ jOlk II-4-- it Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: G/ - (3 ,r Queensbury Building&.Code Enforcement Arrive: am/p•` L, epart: m/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's initials: NAME: j3p..,,, w . PE #: �6b1/.rkl LOCATION: 33 43(�y ,_�.,, /in _ IN .•ECT ON: 6" TYPE OF STRUCTURE:�J�i -rz et i S ? Q ` ' - - ` Comments _ Y ' N N/A OOtI11S S / Piers V Monolithic Slab Reinforcement in Place �/.�� i /11 The contractor is responsible for providing protection from freezing for 48 hours following the placemel}• of the concrete. Materials for this purpose on site. Foundation/Wallpour / Reinforcement in Place Foundation Dampproofing • Foundation/Waterproof gWT Pe of Dampproofing/ a tel roon g .1 Footing Drain Dayii ht or Sump Footing Drain Sto e: 12 inch width 6 inches abo e footing 6 mil poly/for wet areas under slab • Backfill Approval / Plumbinender Slab I PVC"/ ast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMSWoundation Inspection Report.doc January 28,2003 ei,)Qs Permit Number ' ;` p)1( Y 1' 3 REScheck Compliance Certificate Checked By/Date 2003 IECC REScheckSoftware Version 3.6 Release 1 Data filename:C:\Program Files\Check\RE c eck\33 Holly Garage.rck 3P PROJECT TITLE: Single Story Garage, olly Lane Aft CITY: Glens Falls STATE:New York HDD: 7635 CONSTRUCTION TYPE: Single Family WINDOW/WALL RATIO: 0.12 RE COVED DATE: 10/07/04 DATE OF PLANS: 10/1/2004 QC 1 2004 COMPLIANCE:Passes TO\NN p of 1EENSBURY CODE Maximum UA= 176 BU- tPal Your Home UA= 168 4.5%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Raised or Energy Truss 576 38.0 0.0 14 Wall 1: Wood Frame, 16"o.c. 192 21.0 0.0 9 Window 1:Vinyl Frame:Double Pane with Low-E 4 0.340 1 Window 2:Vinyl Frame:Double Pane with Low-E 12 0.340 4 Door 1: Glass 20 0.320 6 Wall 2: Wood Frame, 16"o.c. 221 21.0 0.0 10 Window 3: Vinyl Frame:Double Pane with Low-E 24 0.340 8 Window 4:Vinyl Frame:Double Pane with Low-E 24 0.340 8 Wall 3: Wood Frame, 16"o.c. 192 21.0 0.0 10 Window 5:Vinyl Frame:Double Pane with Low-E 12 0.340 4 Wall 4: Wood Frame, 16"o.c. 192 21.0 0.0 8 Door 2: Solid 39 0.300 12 Door 3: Solid 20 0.300 6 Floor 1: Slab-On-Grade:Heated 96 7.8 68 Insulation depth: 3.5' Boiler 1: Other(Except Gas-Fired Steam), 83 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in RES check Version 3.6 Release 1 (formerly MECchec/) and to comply with the mandatory requirements listed in the RES checklnspection Checklist. Builder/Designer G Date CY/10K 111. 4 ,9aar ,44 idiPP olko 7gs Farmit Number REScheck Compliance Certificate Chedkeday/Dde 2003 I ECC RES drectcSoftwaeVersion 3.6 Rd ease 1 Data fi lenar&C:\Rogran R I es\Check\REScherk\33 Holly Gaegerdk PROJECT TITLE:SngleStoryGaege aHolIy CITY:Glens Fd Is 4•� STATE:Nem York HDD:7635 CONSTRUCTION TYPE:Si ngleFani I \MNDOW/WALL RATIO:0.12 DATE:10/18/04 DATE OF FLANS 10/1/2004 PROJECT DESCRIPTION: 3 Bay Garage<900Sgft Attathed Homed Workshop DESIGNER/CONTRACTOR Brian Hogan/Doug McCal I COMPLIANCE:Passes Mad mum UA=176 Your HomeUA=168 4.5%Better Thai Code(UA) Gross Giazi ng Areaor Canty Cont. or Door Rai meta- RValue R-Value U-Facto UA Cling 1:Rà1 or EnffgyTru 576 38.0 0.0 14 WA 11:Wood Frame,16'o.c. 192 21.0 0.0 9 Window 1:Vinyl Frane Doubl e Paiewith Low-E 4 0.340 1 Window2 Vinyl FranaDouble Pale with Low-E 12 0.340 4 Door 1:Gass 20 0.320 6 Wd 12:Wood Rane,16'o.c. 221 21.0 0.0 10 Wndow3:Vinyl FraneDoubleFanewithLow-E 24 0.340 8 Window 4:Vinyl FraneDoubleParewith Low-E 24 0.340 8 Wd 13:Wood Rare,16'o.c. 192 21.0 0.0 10 \Mndow5:Vinyl Fr anaDoubleFanewith Low-E 12 0.340 4 MI 4:Wood Rarer 16'o.c. 192 21.0 0.0 8 Door2:Solid 39 0.300 12 Door 3:Solid 20 0.300 6 Roar 1:Slab-On-GalaNested 96 7.8 68 L , Insrletiondepth:3.5 Boiler 1:Other(Except Gas-Fi red Stean),83AFUE COMRIANCESTATEMENT:The proposed building designdesai bed here isconsstartwith the buildingplars specifirtions,aidothacalculationssibmittedwiththepermitapplirdion.The proposed building h been deagnedto meet the2003IECCrequiranentsinRES cheiNersi on 3.6 Rd eace1(formerly M EC th&)aid to comply with the maiddoryrequiranatsIistedin the RES chedclnspedionCheddid. Builds/Designs Date REScheck Inspection Checklist 2003 I ECC RESdtedcSoftwaeVersion 3.6 Rd ease 1 DATE:10'18/04 PROJECT TITLE:SngleStory Garsgs 33 Hol ly Lae Bldg. I Dept. use I I Ceilings: [ ] I 1. Cdling1:Rdsedor Energy Trues,R-38.0 cavity insuldion Comments I Insulation must actveveful l height ovatheplatel Ines of exterior walls. I Above-Grade Wails: [ ] I 1. Wall 1:Wood Frans 16'o.a,R21.0 cavity ir>sulation Comments [ ] I 2. Wall 2:Wood Frans 16'o.c,R 21.0 cavity i nsuldi on Comments [ ] I 3. Wall 3:Wood Frans 16'o.c,R 21.0 cavity i nsulati on Comments [ ] I 4. Wall 4:Wood Rams 16'o.c,R 21.0 cavity i nsulation Comments Windows: [ ] 1. Window 1:Vinyl Frans DoubleParewith Low-E,U-factor.0.340 For windowswithout I ebd eel U-factors,descri befe#ures #Pales FraneType ThrnudBreeK?[ ]Yes[ ]No Comments [ ] 2. Wndow2:Vinyl Frame DoubleParewith Low-E,U-factor.0.340 Forwi ndowswithat labeled U-factors,descri beta tunes #Pares FraneType Than lal Breek?[ ]Yes[ ]No Comments [ ] 3. Window 3:Vinyl Frame Double Pa ewith Low-E,U-factor.0.340 Forwi ndowswithout Iabd eel U-factors,deem befeetures #Pares FraneType Thu'id Breda( ]Yes[ ]No Comments [ ] 4. Window4:Vinyl Frans DoublePaiewithLow-E,U-factor:0.340 Forwi ndowswithout labeled U-factors,deem befaturea #Pares FraneType Thermal Break?[ ]Yes[ ]No Comments [ ] 5. W ndow 5:Vi nyl Frans Doubl e Penewith Low E,U-factor.0.340 For wi ndowswit hout labdeel U-fators,de cribefeatures #Pales FraneType Thermal Breek?[ ]Yes[ ]No Comments Doors: [ ] I 1. Door 1:Glass U-factor.0.320 Comments [ ] 2. Door2:Solid,U-factor:0.300 Comments [ ] 3. Door3:Solid,U-factor.0.300 Comments Floors [ ] 1. Floor1:gab-On-GradeNested,3,5insuldiondepth,R7.8contirnmusinsildion Comments 9 ab i nsul di on to ectaid down from thetop of theslab to d I seat 3.5 ft.OR down to d lead the bottom of thesldnthei horizortdIy for atotal distaroeof 3.5 ft. Exterior insuldion mud havearigid,opaque,wedha-residat protediveoovairg that coverstheecposed(thove.grade)insulation and extaidsd least 6 i n.below grade H eating and Cooling Equipment: [ ] 1. Baler1:Ctha(Except C FredStean),83AFUEorhigher MdceaxdModd Number Air Leakage: [ ] .loirts,paidrdions,axldlotherschopaiingsinthebuildingaivdopethdaesouroesofdr ledcagemust beseded. [ ] Recessed lights mud bet)Type ICrded,or2)installed insidea Tproprideair-tightessanbly witha0.5'deaaioefromcombustiblemdaials If non-ICrded,thefixture must beiristdledwitha 3"d eaarcefrom i nsuldi on. Skylights: [ ] Mi ri mum i nsul di on requi remelt for skylight shaftsequei to or grederthary12 inchesis R-19. Vapor Retarder: [ ] Required on thewam-i n-wi nta si de of all non-vented franed cat I i ngs,wal Is,aid floors. Materials Identification: [ ] Mdaidsard equipmart mud beiristdled inaccordaroewiththemarufaduna'sirrstalldion instructions [ ] Mderidsardequipmait mud beidatifiedso that comp!iacecenbeddamined. [ ] Maiufactura mend s for dl Meld led het ngard coon ng equipment aidsavice ward hating equipment mud beprovi ded. [ ] InscldionRvdues,glasngU-factors,axihmtingequipmateffidaxymudbede lymaltedon thebuilding plaisor specifications. Duct I nsulation: [ ] SipplydudsinunconditionedetticsoroutsidethebuildingmudbeinsuldedtoR11. [ ] Return ducts in unconditioned dticsoroutsidethebuilding mud beirrsuldedtoR-6. [ ] Supply dudsin unconditioned spaas must beirisuidedtoR 11. [ ] Rdum duds in unconditioned spaces(except basements)mud beiraindedto R 2. [ ] WhaeexteriorwdIsae used 26 plenums,thewdI mud beirsul dead toR11. I nal di on is not required on return ducts'n basements Duct Construction: [ ] Dud connationstoflaigesofdrdistributionsydariequipmeritmudbesealedadmediaiicalIyfastared. [ ] All joints,seams,axl comet ons mud beseardy fastened with wdds,gaslcds,mastics(adhesives), masstio-plusanbedded-fabri c,ortaoes.Tapesaxl mastics must berded UL 181A or UL 181 B. Exception:Continuously wd ded aid locking-typelongitudind joints aid seams on duds operating d I essthai 2 i n.w.g.(500 Pa). [ ] The HVACsydem must provideameais for Mend ngaraidwdasydans. Temperature Controls: [ ] Thkrrirwtds are required for achsepadeHVACsystem.A maiud orattomdicmearsto patidly restrict or shut off the heti ng aid/or cool ing input to ea:h zoneorfloor shal I be provided. Service Water Heating: [ ] Wdahedaswithvertical piperisas must hareal trap on both theinlet aid outlet unlessthe wda hater hasaiintegral hest trap oris pat of act rwldingsystem. [ ] InsrldedreuldinghotwdapipestothelevdsinTablel. Circulating Hot Water Systems: [ ] Instidedreulding hot wdapipestothelerdsinTablel. Swimming Pools: [ ] All heatedswimmirgpoolsmusthaveaion/offhatasnttdiaidrequireacovaunlessova20% of thehe ti ng energy is from non-depl etd3leauras.Fbol pumps requi reati medodc. Heating and Cooling Piping Insulation: [ ] HVACpipingconveyingfluidsabove105 °For chi lledfluidsbdow55 °Fmust beinsulded to the IevdsinTable2. Tablet: Minimum Insulation Thickness far Circulating Hot Water Pipes. InsuldionThicknessin Inches bvRoeszes HededWda Non-Orculdino Runotts arcuidinaMansandRunouts Tenperature(F) Uoto1" Uoto125' 1.5'to2.0' Oval" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 05 1.0 1.5 100-130 05 0.5 05 1.0 Tablet Minimum Insulation Thickness for H VAC Pipes. RuidTenp. InsuldionThicknemin Inches byRpeSizes , RpinoSvstmiTypes Ratie(F) 2"Runouts 1"aidLeis 1.25'to2' 2.5'to4" Heating Systems Low Re sue'Tenpe ure 201-250 1.0 1.5 1.5 2.0 LowTempedure 120-200 0.5 1.0 1.0 1.5 SteanCondeeete(for feed wda) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Wda,Refrigaad, 40-55 0.5 0.5 0.75 1.0 and Brie: Bdow40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Dq:atment UoQnly)