Loading...
Signed Inspection Report (Thu Apr 8, 2021 at 254 PM)INSPECTION WORKSHEET (SEP-009464-2021) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:SEP-0195-2021 Case Module:Permit Inspection Date:Thu Apr 8, 2021 Inspection Status:Passed Inspector:O'Brien, John Inspection Type:Septic Job Address:Parcel Number:88 MONTRAY RD Queensbury, NY, 12804 296.14-1-6 Contact Type Company Name Name Contractor IBS Septic Applicant IBS Septic Granted Permission Ortiz, Richard Primary Owner Ortiz, Richard Checklist Item Status Permit Card Visible From Road Passed Building Inspector Notes Passed 4/8/21 Septic System Approved As-Built Received Soil Type: Sand Passed Soil Type: Loam Passed Type of Water: Municipal / Well Water Passed Municipal Apr 08, 2021 Page (1) INSPECTION WORKSHEET (SEP-009464-2021) Checklist Item Status Waterline separation distance Passed Absorbtion Fields: Total Length Passed 240' stone & pipe Length of Each Trench Passed 4@60' Depth of Trenches Passed 36"-48" System Use Status Passed 4/8/21 Septic System Approved As-Built Received Size of Stone Passed #2 Building to Tank Passed Existing 4" sch40 pvc Tank to Distribution Box Passed 4" sdr35 pvc Distribution box to Field / Pit Passed 4" sdr35 pvc to 4" sdr35 pvc perforated to looped end of 4" sdr35 pvc to charcoal vent. Opening Sealed:Passed End Cap Passed End looped InletOutlet Pipes & Baffles Passed Apr 08, 2021 Page (2) INSPECTION WORKSHEET (SEP-009464-2021) Checklist Item Status Manholes 12 or less below grade Passed Extension on existing tank. [Provide extension collar if Yes]Passed Extension on existing tank. Locations / Separations Passed Foundation to Tank Passed 10'+ Foundation to Absorption Passed 56' Conforms as per Plot Plan Passed Engineer Report and As-Built Passed As-Built Received Location of system on property Passed Rear left side Apr 08, 2021 Page (3) O'Brien, John