Signed Inspection Report (Mon Apr 12, 2021 at 327 PM)INSPECTION WORKSHEET (SEP-009552-2021)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:SEP-0591-2020 Case Module:Permit
Inspection Date:Mon Apr 12, 2021 Inspection Status:Failed
Inspector:Smith, Mark Inspection Type:Septic
Job Address:Parcel Number:2930 State Rte 9L
Lake George, NY, 12845
239.20-1-19
Contact Type Company Name Name
Primary Owner Francis, Gregory
Contractor Daigle, Nicholas
Granted Permission Francis, Gregory
Engineer Onsite Engineering
Applicant Francis, Gregory
Checklist Item Status
Permit Card Visible From Road Failed
Building Inspector Notes Failed
4/12/21 septic system not approved
- existing seepage pit will need to be uncovered inspected and approved.
- clarus tank will need to be opened on inlet and outlet side and verified as operational
- A letter from the design engineer Eric Murdock stating that the system was installed to his satisfaction will be
required.
- proof of electrical inspection.
Public Sewer Sign-Off Failed
Roof gutters don't discharge over leach field Failed
Apr 12, 2021 Page (1)
INSPECTION WORKSHEET (SEP-009552-2021)
Checklist Item Status
Soil Type: Sand Failed
Soil Type: Loam Failed
Soil Type: Clay Failed
Type of Water: Municipal / Well Water Failed
Waterline separation distance Failed
Well separation distance Failed
Well Casing Lengt: 50ft +/-Failed
Absorbtion Fields: Total Length Failed
Septic system field above flood plain Failed
Sump pump not connected to septic system Failed
Septic tanks & pump station anchored in flood zone Failed
Apr 12, 2021 Page (2)
INSPECTION WORKSHEET (SEP-009552-2021)
Checklist Item Status
Water softener not hooked to septic system Failed
Length of Each Trench Failed
Depth of Trenches Failed
System Use Status Failed
Size of Stone Failed
Seepage Pits: Number Failed
Size:Failed
Stone Size:Failed
Building to Tank Failed
Tank to Distribution Box Failed
Distribution box to Field / Pit Failed
Opening Sealed:Failed
Apr 12, 2021 Page (3)
INSPECTION WORKSHEET (SEP-009552-2021)
Checklist Item Status
End Cap Failed
InletOutlet Pipes & Baffles Failed
Manholes 12 or less below grade Failed
[Provide extension collar if Yes]Failed
Locations / Separations Failed
Foundation to Tank Failed
Foundation to Absorption Failed
Separation of Pits Failed
Conforms as per Plot Plan Failed
Engineer Report and As-Built Failed
ETU Maintenance Contract provided Failed
Apr 12, 2021 Page (4)
INSPECTION WORKSHEET (SEP-009552-2021)
Checklist Item Status
Location of system on property Failed
Apr 12, 2021 Page (5)
Smith, Mark