Loading...
Signed Inspection Report (Mon Apr 12, 2021 at 327 PM)INSPECTION WORKSHEET (SEP-009552-2021) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:SEP-0591-2020 Case Module:Permit Inspection Date:Mon Apr 12, 2021 Inspection Status:Failed Inspector:Smith, Mark Inspection Type:Septic Job Address:Parcel Number:2930 State Rte 9L Lake George, NY, 12845 239.20-1-19 Contact Type Company Name Name Primary Owner Francis, Gregory Contractor Daigle, Nicholas Granted Permission Francis, Gregory Engineer Onsite Engineering Applicant Francis, Gregory Checklist Item Status Permit Card Visible From Road Failed Building Inspector Notes Failed 4/12/21 septic system not approved - existing seepage pit will need to be uncovered inspected and approved. - clarus tank will need to be opened on inlet and outlet side and verified as operational - A letter from the design engineer Eric Murdock stating that the system was installed to his satisfaction will be required. - proof of electrical inspection. Public Sewer Sign-Off Failed Roof gutters don't discharge over leach field Failed Apr 12, 2021 Page (1) INSPECTION WORKSHEET (SEP-009552-2021) Checklist Item Status Soil Type: Sand Failed Soil Type: Loam Failed Soil Type: Clay Failed Type of Water: Municipal / Well Water Failed Waterline separation distance Failed Well separation distance Failed Well Casing Lengt: 50ft +/-Failed Absorbtion Fields: Total Length Failed Septic system field above flood plain Failed Sump pump not connected to septic system Failed Septic tanks & pump station anchored in flood zone Failed Apr 12, 2021 Page (2) INSPECTION WORKSHEET (SEP-009552-2021) Checklist Item Status Water softener not hooked to septic system Failed Length of Each Trench Failed Depth of Trenches Failed System Use Status Failed Size of Stone Failed Seepage Pits: Number Failed Size:Failed Stone Size:Failed Building to Tank Failed Tank to Distribution Box Failed Distribution box to Field / Pit Failed Opening Sealed:Failed Apr 12, 2021 Page (3) INSPECTION WORKSHEET (SEP-009552-2021) Checklist Item Status End Cap Failed InletOutlet Pipes & Baffles Failed Manholes 12 or less below grade Failed [Provide extension collar if Yes]Failed Locations / Separations Failed Foundation to Tank Failed Foundation to Absorption Failed Separation of Pits Failed Conforms as per Plot Plan Failed Engineer Report and As-Built Failed ETU Maintenance Contract provided Failed Apr 12, 2021 Page (4) INSPECTION WORKSHEET (SEP-009552-2021) Checklist Item Status Location of system on property Failed Apr 12, 2021 Page (5) Smith, Mark